Design and Fabrication of an Injection Tool for Neuromuscular Microstimulators

The injection of small implants into precisely localized sites within the body is a difficult task usually undertaken by surgeons or interventive radiologists. We have designed, produced and tested a simple tool for implanting BION™ wireless microstimulators as an outpatient office procedure. The ability of BIONs to elicit a desired muscle contraction depends on their placement near the motor fibers that innervate the muscle fibers, providing both the requirement and a means for achieving accurate placement. The implant is preloaded into the tip of the cannula of a two-piece insertion tool made from non-conductive polymers. Trial stimulation pulses are generated by the implant as the tool is manipulated into the desired position. The implant is released by withdrawing the cannula over the implant, preserving both the relative location of the implant’s electrodes with respect to the target and determining its desired axial orientation, which is important for implants containing motion sensors. The BION Insertion Tool has been used for over 30 BION implants in human subjects to date.

[1]  R. Cook,et al.  Concepts and Applications of Finite Element Analysis , 1974 .

[2]  E. S. Kim,et al.  Single- and Triaxis Piezoelectric-Bimorph Accelerometers , 2008, Journal of Microelectromechanical Systems.

[3]  G E Loeb,et al.  Functional electrical stimulation using microstimulators to correct foot drop: a case study. , 2004, Canadian journal of physiology and pharmacology.

[4]  Allison M. Okamura,et al.  Modeling of needle insertion forces for robot-assisted percutaneous therapy , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[5]  Lloyd Js,et al.  Auto-disable syringes for immunization: issues in technology transfer. , 1999 .

[6]  C. J. Clements,et al.  Technologies to Improve Immunisation Safety , 2001, Drug safety.

[7]  Rajni V. Patel,et al.  Needle insertion into soft tissue: a survey. , 2007, Medical engineering & physics.

[8]  N. Özkaya,et al.  Fundamentals of Biomechanics: Equilibrium, Motion, and Deformation , 1991 .

[9]  J. Colton,et al.  Fabrication and analysis of plastic hypodermic needles , 2005, Journal of medical engineering & technology.

[10]  Qiang Zou,et al.  Implantable biaxial piezoresistive accelerometer for sensorimotor control , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  Qiang Zou,et al.  Sensing human arm posture with implantable sensors , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[12]  G. Loeb,et al.  The BION devices: injectable interfaces with peripheral nerves and muscles. , 2006, Neurosurgical focus.

[13]  G. Loeb,et al.  Prevention of muscle disuse atrophy by low-frequency electrical stimulation in rats , 2003, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[14]  J. Lloyd,et al.  Auto-disable syringes for immunization: issues in technology transfer. , 1999, Bulletin of the World Health Organization.

[15]  A. Belegundu,et al.  Introduction to Finite Elements in Engineering , 1990 .

[16]  Yongde Zhang,et al.  Evaluation of robotic needle insertion in conjunction with in vivo manual insertion in the operating room , 2005, ROMAN 2005. IEEE International Workshop on Robot and Human Interactive Communication, 2005..

[17]  G. Loeb,et al.  First Clinical Experience with BION Implants for Therapeutic Electrical Stimulation , 2004, Neuromodulation : journal of the International Neuromodulation Society.

[18]  Gerald E. Loeb,et al.  BION™ Implants for Therapeutic and Functional Electrical Stimulation , 2000 .

[19]  Septimiu E. Salcudean,et al.  Needle insertion modeling and simulation , 2003, IEEE Trans. Robotics Autom..