Synthesis, Chromatographic Separation, and Characterization of Near-Infrared Labeled DNA Oligomers for Use in DNA Sequencing

Traditionally, visible fluorophores have been used as labels in DNA sequencing. They absorb and fluoresce in a region of the spectrum that is susceptible to biological interferences in sequencing samples. The increased noise level due to autofluorescence of glass, solvent, or impurities can greatly reduce the potential sensitivity of the analysis. In an attempt to increase the sensitivity, we have investigated the use of near-infrared (near-IR) fluorophores as labels in DNA sequencing. Near-IR fluorophores possess spectral properties which are observed between 700 and 1200 nm, a region with characteristically little interference by biomolecules. Therefore, the detection of near-IR dyes is not limited by noise levels, but rather by detector capabilities. Near-IR dyes are also suitable for selective excitation with commercially available laser diodes which can further enhance the observed fluorescence signal. We have covalently linked fuction-alized near-IR dyes to moiled DNA oligomers for use in DNA sequencing. We report the synthesis and chromatographic purification of near-IR-labeled DNA oligomers. Wefurther discuss the inherent properties of the conjugates and their use in DNA sequencing procedures

[1]  J. M. Prober,et al.  A system for rapid DNA sequencing with fluorescent chain-terminating dideoxynucleotides. , 1987, Science.

[2]  C. R. Connell,et al.  DNA sequencing with dye-labeled terminators and T7 DNA polymerase: effect of dyes and dNTPs on incorporation of dye-terminators and probability analysis of termination fragments. , 1992, Nucleic acids research.

[3]  L. Strekowski,,et al.  Facile Derivatizations of Heptamethine Cyanine Dyes , 1992 .

[4]  L. Strekowski,,et al.  Substitution reactions of a nucleofugal group in heptamethine cyanine dyes. Synthesis of an isothiocyanato derivative for labeling of proteins with a near-infrared chromophore , 1992 .

[5]  G. Patonay,et al.  Near-infrared fluorescence probe for pH determination , 1991 .

[6]  R. J. Williams,et al.  Comparison of covalent and noncovalent labeling with near-infrared dyes for the high-performance liquid chromatographic determination of human serum albumin. , 1993, Analytical chemistry.

[7]  Lloyd M. Smith,et al.  Fluorescence detection in automated DNA sequence analysis , 1986, Nature.

[8]  Ellson Y. Chen,et al.  Overview of manual and automated DNA sequencing by the dideoxy chain termination method , 1991 .

[9]  S. L. Sutter,et al.  Continuous, on‐line DNA sequencing using a versatile infrared laser scanner/electrophoresis apparatus , 1992, Electrophoresis.

[10]  L. Middendorf,et al.  Continuous, on-line DNA sequencing using oligodeoxynucleotide primers with multiple fluorophores. , 1988, Proceedings of the National Academy of Sciences of the United States of America.

[11]  A. Waggoner,et al.  Cyanine dye labeling reagents containing isothiocyanate groups. , 1989, Cytometry.

[12]  R. C. Benson,et al.  Absorption and fluorescence properties of cyanine dyes , 1977 .

[13]  Gabor Patonay,et al.  Evaluation of Near Infrared Dyes as Labels for Immunoassays Utilizing Laser Diode Detection: Development of Near Infrared Dye Immunoassay (NIRDIA) , 1992 .

[14]  D E Wemmer,et al.  Stable fluorescent complexes of double-stranded DNA with bis-intercalating asymmetric cyanine dyes: properties and applications. , 1992, Nucleic acids research.

[15]  F. Schubert,et al.  One-step labelling of oligonucleotides with fluoresceine during automated synthesis. , 1990, Nucleic acids research.