Development and Application of Stereo Camera-Based Upper Extremity Workspace Evaluation in Patients with Neuromuscular Diseases

Background The concept of reachable workspace is closely tied to upper limb joint range of motion and functional capability. Currently, no practical and cost-effective methods are available in clinical and research settings to provide arm-function evaluation using an individual’s three-dimensional (3D) reachable workspace. A method to intuitively display and effectively analyze reachable workspace would not only complement traditional upper limb functional assessments, but also provide an innovative approach to quantify and monitor upper limb function. Methodology/Principal Findings A simple stereo camera-based reachable workspace acquisition system combined with customized 3D workspace analysis algorithm was developed and compared against a sub-millimeter motion capture system. The stereo camera-based system was robust, with minimal loss of data points, and with the average hand trajectory error of about 40 mm, which resulted to ∼5% error of the total arm distance. As a proof-of-concept, a pilot study was undertaken with healthy individuals (n = 20) and a select group of patients with various neuromuscular diseases and varying degrees of shoulder girdle weakness (n = 9). The workspace envelope surface areas generated from the 3D hand trajectory captured by the stereo camera were compared. Normalization of acquired reachable workspace surface areas to the surface area of the unit hemi-sphere allowed comparison between subjects. The healthy group’s relative surface areas were 0.618±0.09 and 0.552±0.092 (right and left), while the surface areas for the individuals with neuromuscular diseases ranged from 0.03 and 0.09 (the most severely affected individual) to 0.62 and 0.50 (very mildly affected individual). Neuromuscular patients with severe arm weakness demonstrated movement largely limited to the ipsilateral lower quadrant of their reachable workspace. Conclusions/Significance The findings indicate that the proposed stereo camera-based reachable workspace analysis system is capable of distinguishing individuals with varying degrees of proximal upper limb functional impairments.

[1]  Kenneth W. Kennedy,et al.  Reach Capability of Men and Women: A Three-Dimensional Analysis , 1978 .

[2]  M. Province,et al.  Reliability of goniometric measurements in patients with Duchenne muscular dystrophy. , 1985, Physical therapy.

[3]  Richard W. Bohannon,et al.  Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity. , 1987, Physical therapy.

[4]  Shu Li,et al.  The measurement of functional arm reach envelopes for young Chinese males , 1990 .

[5]  A. Zupan Assessment of the functional abilities of the upper limbs in patients with neuromuscular diseases. , 1996, Disability and rehabilitation.

[6]  Chandrajit L. Bajaj,et al.  Sampling and reconstructing manifolds using alpha-shapes , 1997, CCCG.

[7]  S. Kumar Advances in Occupational Ergonomics and Safety , 1998 .

[8]  C Disselhorst-Klug,et al.  A marker-based measurement procedure for unconstrained wrist and elbow motions. , 1999, Journal of biomechanics.

[9]  Jingzhou Yang,et al.  Towards understanding the workspace of human limbs , 2004, Ergonomics.

[10]  Jadran Lenarčič,et al.  Kinematic Model for Determination of Human Arm Reachable Workspace , 2005 .

[11]  F.C.T. van der Helm,et al.  Kinematic Design to Improve Ergonomics in Human Machine Interaction , 2006, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[12]  Rama Chellappa,et al.  Motion Based Correspondence for 3D Tracking of Multiple Dim Objects , 2006, 2006 IEEE International Conference on Acoustics Speech and Signal Processing Proceedings.

[13]  N Klopcar,et al.  A kinematic model of the shoulder complex to evaluate the arm-reachable workspace. , 2007, Journal of biomechanics.

[14]  Takuma Suzuki,et al.  Noise of Acoustic Doppler Velocimeter Data in Bubbly Flows , 2007 .

[15]  Zheng Jiangbin,et al.  Multi-markers 3D tracking algorithm in a video motion capture system , 2008 .

[16]  J. Roy,et al.  The kinematics of upper extremity reaching: a reliability study on people with and without shoulder impingement syndrome , 2010, Sports medicine, arthroscopy, rehabilitation, therapy & technology : SMARTT.

[17]  M. Mullaney,et al.  Reliability of shoulder range of motion comparing a goniometer to a digital level , 2010, Physiotherapy theory and practice.

[18]  Devendra N. Behara,et al.  Anthropometric modelling for the determination of 3-D maximum functional reach , 2011 .

[19]  M. Kolber,et al.  The reliability and concurrent validity of scapular plane shoulder elevation measurements using a digital inclinometer and goniometer , 2012, Physiotherapy theory and practice.

[20]  Stepán Obdrzálek,et al.  Real-Time Human Pose Detection and Tracking for Tele-Rehabilitation in Virtual Reality , 2012, MMVR.