Light microscopic and scanning electron microscopic retrieval analyses of implanted biomaterials retrieved from humans and experimental animals.

This paper reports analysis obtained from 200 implant cases retrieved from humans and submitted to the American Academy of Implant Dentistry Research Foundation, Medical College of Georgia implant retrieval center. The samples that were not decalcified were embedded in polymethylmethacrylate and examined with scanning electron microscopy and routine light, polarized, or Nomarski microscopy. Cases included both orthopedic and dental implants, as well as entire mandibles and portions of maxillae obtained at autopsy. A significant number of submitted implants had substantial amounts of adhered bone, which permitted evaluation of human bone remodeling to osseointegrated implants. These implants failed because of implant fracture. As was observed with animal studies, healthy bone supported these implants, with the bone containing an interdigitating canaliculi network that provided communication between interfacial osteocytes and osteocytes deeper within the remodeled osteonal and trabecular bone. Early dental implants containing a coating of beads showed a connective tissue interface, which corresponded to the bead surface of specific orthopedic implants that underwent some degree of micromovement. This is in contrast with the excellent response reported for successful contemporary beaded implants. Significant numbers of osseointegrated fractured hydroxyapatite (HA)-coated dental implants demonstrated the adequate serviceability of these implants before biomaterial fracture. In contrast, the HA coating was dissociated from retrieved orthopedic implants, leading to extensive cup loosening and case failure. This study, therefore, underscores the need for evaluation of failed human dental and orthopedic implants. Correlations can be drawn between human retrieval and experimental animal studies.

[1]  Green Ej Implantation of artificial crown and bridge abutments. 1913. , 2008 .

[2]  P. Aspenberg,et al.  Pressure‐induced periprosthetic osteolysis: A rat model , 2000, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[3]  M. Wilson,et al.  Retrieval analyses of implanted biomaterials: light microscopic and scanning electron microscopic analyses of implants retrieved from humans. , 1999, The Journal of oral implantology.

[4]  T. Young,et al.  Ultrastructural analyses of the attachment (bonding) zone between bone and implanted biomaterials. , 1998, Journal of biomedical materials research.

[5]  K. Buttle,et al.  Composite morphology of the bone and associated support-tissue interfaces to osseointegrated dental implants: TEM and HVEM analyses. , 1997, The International journal of oral & maxillofacial implants.

[6]  P. Hanes,et al.  A comparative investigation in dogs: 2-year morphometric results of the dental implant--bone interface. , 1996, The International journal of oral & maxillofacial implants.

[7]  R. Mckinney,et al.  Prospective investigation of the single-crystal sapphire endosteal dental implant in humans: ten-year results. , 1995, The Journal of oral implantology.

[8]  F. Howell,et al.  Light microscopic and scanning electron microscopic analyses of dental implants retrieved from humans. , 1994, The Journal of oral implantology.

[9]  P. Hanes,et al.  Osteogenesis at the dental implant interface: high-voltage electron microscopic and conventional transmission electron microscopic observations. , 1993, Journal of biomedical materials research.

[10]  R. Bloebaum,et al.  Osteolysis from a press-fit hydroxyapatite-coated implant. A case study. , 1993, The Journal of arthroplasty.

[11]  K. Bachus,et al.  Postmortem comparative analysis of titanium and hydroxyapatite porous-coated femoral implants retrieved from the same patient. A case study. , 1993, The Journal of arthroplasty.

[12]  P. Hanes,et al.  Correlative transmission electron microscopic and scanning electron microscopic observations of the tissues supporting endosteal blade implants. , 1992, The Journal of oral implantology.

[13]  P. Hanes,et al.  Electron microscopy of bone response to titanium cylindrical screw-type endosseous dental implants. , 1992, The International journal of oral & maxillofacial implants.

[14]  J. B. Brunski,et al.  36. Influence of Biomechanical Factors at the Bone-Biomaterial Interface , 1991 .

[15]  G. Parr,et al.  Dental implants retrieved from humans: a diagnostic light microscopic review of the findings in seven cases of failure. , 1991, The International journal of oral & maxillofacial implants.

[16]  J. Lemons Dental implant retrieval analyses. , 1988, Journal of dental education.

[17]  Tomas Albrektsson,et al.  Osseointegrated Oral implants , 1988 .

[18]  G. Parr,et al.  Clinical and histological observations of failed two-stage titanium alloy basket implants. , 1988, The International journal of oral & maxillofacial implants.

[19]  S D Cook,et al.  Interface mechanics and histology of titanium and hydroxylapatite-coated titanium for dental implant applications. , 1987, The International journal of oral & maxillofacial implants.

[20]  R. James,et al.  A critical review of the "osseointegrated" literature. , 1986, The New York state dental journal.

[21]  R. Pilliar,et al.  A Histological Assessment of the Initial Healing Response Adjacent to Porous-surfaced, Titanium Alloy Dental Implants in Dogs , 1986, Journal of dental research.

[22]  J. Lemons,et al.  Biomaterials, biocompatibility, and peri-implant considerations. , 1986, Dental clinics of North America.

[23]  D. Misiek,et al.  A sixteen-year evaluation of the mandibular staple bone plate. , 1986, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[24]  D. Steflik,et al.  Scanning electron microscopy of plasma etched implant specimens. , 1984, Stain technology.

[25]  D. Steflik,et al.  The biomaterial-tissue interface: a morphological study utilizing conventional and alternative ultrastructural modalities. , 1984, Scanning electron microscopy.

[26]  D. Steflik,et al.  Simultaneous histological preparation of bone, soft tissue and implanted biomaterials for light microscopic observations. , 1982, Stain technology.

[27]  P I Brånemark,et al.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. , 1981, International journal of oral surgery.

[28]  L. Garfinkel,et al.  A statistical evaluation of 952 endosteal implants in humans. , 1977, Journal of the American Dental Association.

[29]  I Macnab,et al.  The rate of bone ingrowth into porous metal. , 1976, Journal of biomedical materials research.

[30]  J. Natiella,et al.  The crypt surface of blade-vent implants in clinical failure: an electron microscopic study. , 1974, The Journal of prosthetic dentistry.

[31]  Greenfield Ej,et al.  Implantation of artificial crown and bridge abutments. , 1971 .