Diffusion Microscopist Simulator: A General Monte Carlo Simulation System for Diffusion Magnetic Resonance Imaging

This article describes the development and application of an integrated, generalized, and efficient Monte Carlo simulation system for diffusion magnetic resonance imaging (dMRI), named Diffusion Microscopist Simulator (DMS). DMS comprises a random walk Monte Carlo simulator and an MR image synthesizer. The former has the capacity to perform large-scale simulations of Brownian dynamics in the virtual environments of neural tissues at various levels of complexity, and the latter is flexible enough to synthesize dMRI datasets from a variety of simulated MRI pulse sequences. The aims of DMS are to give insights into the link between the fundamental diffusion process in biological tissues and the features observed in dMRI, as well as to provide appropriate ground-truth information for the development, optimization, and validation of dMRI acquisition schemes for different applications. The validity, efficiency, and potential applications of DMS are evaluated through four benchmark experiments, including the simulated dMRI of white matter fibers, the multiple scattering diffusion imaging, the biophysical modeling of polar cell membranes, and the high angular resolution diffusion imaging and fiber tractography of complex fiber configurations. We expect that this novel software tool would be substantially advantageous to clarify the interrelationship between dMRI and the microscopic characteristics of brain tissues, and to advance the biophysical modeling and the dMRI methodologies.

[1]  J. E. Tanner,et al.  Spin diffusion measurements : spin echoes in the presence of a time-dependent field gradient , 1965 .

[2]  J. E. Tanner Use of the Stimulated Echo in NMR Diffusion Studies , 1970 .

[3]  A. C. Young,et al.  Restricted diffusion in biophysical systems. Experiment. , 1974, Biophysical journal.

[4]  Irving J. Lowe,et al.  A modified pulsed gradient technique for measuring diffusion in the presence of large background gradients , 1980 .

[5]  C. Nicholson,et al.  Ion diffusion modified by tortuosity and volume fraction in the extracellular microenvironment of the rat cerebellum. , 1981, The Journal of physiology.

[6]  M C Bushell,et al.  PRELIMINARY COMMUNICATION: The spatial mapping of translational diffusion coefficients by the NMR imaging technique , 1985 .

[7]  P. Grenier,et al.  MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. , 1986, Radiology.

[8]  Jörg Kärger,et al.  Principles and Application of Self-Diffusion Measurements by Nuclear Magnetic Resonance , 1988 .

[9]  J. Frahm,et al.  MRI of “diffusion” in the human brain: New results using a modified CE‐FAST sequence , 1989, Magnetic resonance in medicine.

[10]  J. Kurhanewicz,et al.  Diffusion-weighted MR imaging of acute stroke: correlation with T2-weighted and magnetic susceptibility-enhanced MR imaging in cats. , 1990, AJNR. American journal of neuroradiology.

[11]  P. Callaghan Principles of Nuclear Magnetic Resonance Microscopy , 1991 .

[12]  U. F. Hazlewood,et al.  Diffusion of water in tissues and MRI , 1991, Magnetic resonance in medicine.

[13]  H. Pfeifer Principles of Nuclear Magnetic Resonance Microscopy , 1992 .

[14]  Janez Stepišnik,et al.  Time-dependent self-diffusion by NMR spin-echo , 1993 .

[15]  K. Svoboda,et al.  Time-dependent diffusion of water in a biological model system. , 1994, Proceedings of the National Academy of Sciences of the United States of America.

[16]  P. Basser,et al.  Estimation of the effective self-diffusion tensor from the NMR spin echo. , 1994, Journal of magnetic resonance. Series B.

[17]  P. Basser,et al.  MR diffusion tensor spectroscopy and imaging. , 1994, Biophysical journal.

[18]  Mitra,et al.  Multiple wave-vector extensions of the NMR pulsed-field-gradient spin-echo diffusion measurement. , 1995, Physical review. B, Condensed matter.

[19]  A. Szafer,et al.  An analytical model of restricted diffusion in bovine optic nerve , 1997, Magnetic resonance in medicine.

[20]  D. van Dusschoten,et al.  Modeling of self-diffusion and relaxation time NMR in multi-compartment systems. , 1998, Journal of magnetic resonance.

[21]  A. Barzykin EXACT SOLUTION OF THE TORREY-BLOCH EQUATION FOR A SPIN ECHO IN RESTRICTED GEOMETRIES , 1998 .

[22]  M. Horsfield,et al.  Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging , 1999, Magnetic resonance in medicine.

[23]  S C Williams,et al.  Non‐invasive assessment of axonal fiber connectivity in the human brain via diffusion tensor MRI , 1999, Magnetic resonance in medicine.

[24]  M. Raichle,et al.  Tracking neuronal fiber pathways in the living human brain. , 1999, Proceedings of the National Academy of Sciences of the United States of America.

[25]  C. Nicholson,et al.  Changes in brain cell shape create residual extracellular space volume and explain tortuosity behavior during osmotic challenge. , 2000, Proceedings of the National Academy of Sciences of the United States of America.

[26]  P. Basser,et al.  In vivo fiber tractography using DT‐MRI data , 2000, Magnetic resonance in medicine.

[27]  C. Poupon,et al.  Regularization of Diffusion-Based Direction Maps for the Tracking of Brain White Matter Fascicles , 2000, NeuroImage.

[28]  Ching-Po Lin,et al.  Validation of Diffusion Tensor Magnetic Resonance Axonal Fiber Imaging with Registered Manganese-Enhanced Optic Tracts , 2001, NeuroImage.

[29]  C. Beaulieu,et al.  The basis of anisotropic water diffusion in the nervous system – a technical review , 2002, NMR in biomedicine.

[30]  Susumu Mori,et al.  Fiber tracking: principles and strategies – a technical review , 2002, NMR in biomedicine.

[31]  Frank J Vergeldt,et al.  Modelling of self-diffusion and relaxation time NMR in multicompartment systems with cylindrical geometry. , 2002, Journal of magnetic resonance.

[32]  Y. Cohen,et al.  High b‐value q‐space analyzed diffusion‐weighted MRS and MRI in neuronal tissues – a technical review , 2002, NMR in biomedicine.

[33]  Paul T. Callaghan,et al.  Locally anisotropic motion in a macroscopically isotropic system: displacement correlations measured using double pulsed gradient spin‐echo NMR , 2002 .

[34]  P. Kuchel,et al.  Simulations of molecular diffusion in lattices of cells: insights for NMR of red blood cells. , 2002, Biophysical journal.

[35]  Ole P. Ottersen,et al.  The molecular basis of water transport in the brain , 2003, Nature Reviews Neuroscience.

[36]  J. Gore,et al.  Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain , 2003, Magnetic resonance in medicine.

[37]  G. L. Bretthorst,et al.  Statistical model for diffusion attenuated MR signal , 2003, Magnetic resonance in medicine.

[38]  Denis Le Bihan,et al.  Looking into the functional architecture of the brain with diffusion MRI , 2003, Nature Reviews Neuroscience.

[39]  V. Wedeen,et al.  Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo , 2003, Magnetic resonance in medicine.

[40]  Ching Yao,et al.  Validation of diffusion spectrum magnetic resonance imaging with manganese-enhanced rat optic tracts and ex vivo phantoms , 2003, NeuroImage.

[41]  P. Basser,et al.  New modeling and experimental framework to characterize hindered and restricted water diffusion in brain white matter , 2004, Magnetic resonance in medicine.

[42]  Christopher D. Kroenke,et al.  Use of magnetic resonance to measure molecular diffusion within the brain extracellular space , 2004, Neurochemistry International.

[43]  Z. Berente,et al.  The existence of biexponential signal decay in magnetic resonance diffusion‐weighted imaging appears to be independent of compartmentalization , 2004, Magnetic resonance in medicine.

[44]  Jonathan Nissanov,et al.  Assessment of axonal fiber tract architecture in excised rat spinal cord by localized NMR q‐space imaging: Simulations and experimental studies , 2004, Magnetic resonance in medicine.

[45]  D. Tuch Q‐ball imaging , 2004, Magnetic resonance in medicine.

[46]  D. LeBihan,et al.  Validation of q-ball imaging with a diffusion fibre-crossing phantom on a clinical scanner , 2005, Philosophical Transactions of the Royal Society B: Biological Sciences.

[47]  Jean-Francois Mangin,et al.  Fiber Tracking in q-Ball Fields Using Regularized Particle Trajectories , 2005, IPMI.

[48]  D. Le Bihan,et al.  Direct and fast detection of neuronal activation in the human brain with diffusion MRI. , 2006, Proceedings of the National Academy of Sciences of the United States of America.

[49]  L. R. Frank,et al.  Simulation of the MRI Measurement of Diffusion in Realistic Neural Tissue Models , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[50]  Duan Xu,et al.  Q‐ball reconstruction of multimodal fiber orientations using the spherical harmonic basis , 2006, Magnetic resonance in medicine.

[51]  Karla L Miller,et al.  Evidence for a vascular contribution to diffusion FMRI at high b value , 2007, Proceedings of the National Academy of Sciences.

[52]  Sharon Peled,et al.  New Perspectives on the Sources of White Matter DTI Signal , 2007, IEEE Transactions on Medical Imaging.

[53]  D. Le Bihan The ‘wet mind’: water and functional neuroimaging , 2007, Physics in medicine and biology.

[54]  E. Achten,et al.  The design of anisotropic diffusion phantoms for the validation of diffusion weighted magnetic resonance imaging , 2008, Physics in medicine and biology.

[55]  P. Basser,et al.  Axcaliber: A method for measuring axon diameter distribution from diffusion MRI , 2008, Magnetic resonance in medicine.

[56]  J. Mangin,et al.  New diffusion phantoms dedicated to the study and validation of high‐angular‐resolution diffusion imaging (HARDI) models , 2008, Magnetic resonance in medicine.

[57]  E. Achten,et al.  Simulation and experimental verification of the diffusion in an anisotropic fiber phantom. , 2008, Journal of magnetic resonance.

[58]  Chun-Hung Yeh,et al.  Reduced Encoding Diffusion Spectrum Imaging Implemented With a Bi-Gaussian Model , 2008, IEEE Transactions on Medical Imaging.

[59]  Peter J Basser,et al.  Microscopic anisotropy revealed by NMR double pulsed field gradient experiments with arbitrary timing parameters. , 2008, The Journal of chemical physics.

[60]  Chun-Hung Yeh,et al.  Evaluation of the accuracy and angular resolution of q-ball imaging , 2008, NeuroImage.

[61]  Chun-Hung Yeh,et al.  Resolving crossing fibres using constrained spherical deconvolution: Validation using diffusion-weighted imaging phantom data , 2008, NeuroImage.

[62]  D. Alexander A general framework for experiment design in diffusion MRI and its application in measuring direct tissue‐microstructure features , 2008, Magnetic resonance in medicine.

[63]  Daniel C. Alexander,et al.  Convergence and Parameter Choice for Monte-Carlo Simulations of Diffusion MRI , 2009, IEEE Transactions on Medical Imaging.

[64]  Gregory T. Balls,et al.  A simulation environment for diffusion weighted MR experiments in complex media , 2009, Magnetic resonance in medicine.

[65]  Rachid Deriche,et al.  Deterministic and Probabilistic Tractography Based on Complex Fibre Orientation Distributions , 2009, IEEE Transactions on Medical Imaging.

[66]  Peter J Basser,et al.  Observation of restricted diffusion in the presence of a free diffusion compartment: single- and double-PFG experiments. , 2009, Journal of magnetic resonance.

[67]  Alan Connelly,et al.  A software tool to generate simulated white matter structures for the assessment of fibre-tracking algorithms , 2009, NeuroImage.

[68]  Jeremy J. Flint,et al.  Diffusion weighted magnetic resonance imaging of neuronal activity in the hippocampal slice model , 2009, NeuroImage.

[69]  Chun-Hung Yeh,et al.  The effect of finite diffusion gradient pulse duration on fibre orientation estimation in diffusion MRI , 2010, NeuroImage.

[70]  J. Frank,et al.  Neurite beading is sufficient to decrease the apparent diffusion coefficient after ischemic stroke , 2010, Proceedings of the National Academy of Sciences.

[71]  Peter J Basser,et al.  Noninvasive bipolar double-pulsed-field-gradient NMR reveals signatures for pore size and shape in polydisperse, randomly oriented, inhomogeneous porous media. , 2010, The Journal of chemical physics.

[72]  Bennett A Landman,et al.  Complex geometric models of diffusion and relaxation in healthy and damaged white matter , 2009, NMR in biomedicine.

[73]  Peter J Basser,et al.  Detecting diffusion-diffraction patterns in size distribution phantoms using double-pulsed field gradient NMR: Theory and experiments. , 2010, The Journal of chemical physics.

[74]  Tim B. Dyrby,et al.  Orientationally invariant indices of axon diameter and density from diffusion MRI , 2010, NeuroImage.

[75]  Mark F. Lythgoe,et al.  High-Fidelity Meshes from Tissue Samples for Diffusion MRI Simulations , 2010, MICCAI.

[76]  Christopher A Waudby,et al.  GPU accelerated Monte Carlo simulation of pulsed-field gradient NMR experiments. , 2011, Journal of magnetic resonance.