Reproducibility of cephalometric landmarks on conventional film, hardcopy, and monitor-displayed images obtained by the storage phosphor technique.

The aim of the present study was to evaluate and compare the reproducibility of cephalometric landmarks on (1) conventional films, and images acquired by storage phosphor digital radiography both on (2) hardcopy and (3) monitor-displayed versions. The material consisted of 19 cephalograms for each image modality. The phosphor plates were scanned in an image reader and the 10-bit normalized, raw data digital images were converted to 8-bit TIFF images for PC monitor-display. The digital hardcopies were produced in a laser printer. Six observers were asked to record 21 cephalometric landmarks on each conventional film, hardcopy, and monitor-displayed image. For the films and hardcopies, the landmark co-ordinates were recorded via a digitizing tablet. For the monitor-displayed images, the co-ordinates were recorded directly from the monitor using a dedicated Windows-based cephalometric program. Reproducibility was defined as an observer's deviation (in mm) from the mean between all observers. Differences between the image modalities and between the observers were tested by two-way analysis of variance for each landmark. There was a statistically significant difference between the reproducibility of film, hardcopy and monitor-displayed images in 11 of the 21 landmarks. There was no unequivocal trend that one modality was always the best. For a full cephalometric recording (the sum of all 21 landmarks), the monitor-displayed images (mean = 25.3 mm) had a lower precision than film (P < 0.005) and hard-copy (P < 0.02). There was no significant difference between film (mean = 21.8 mm) and hardcopy (mean = 22.8 mm). The lower reproducibility seen for the monitor-displayed images is most probably of little clinical significance.

[1]  A. Wenzel,et al.  Effect of exposure time on in vitro caries diagnosis using the Digora system. , 1997, European journal of oral sciences.

[2]  A Jäger,et al.  Digital image processing in cephalometric analysis. , 1989, Schweizer Monatsschrift fur Zahnmedizin = Revue mensuelle suisse d'odonto-stomatologie = Rivista mensile svizzera di odontologia e stomatologia.

[3]  K Seki,et al.  Exposure reduction in cephalography with a digital photostimulable phosphor imaging system. , 1993, Dento maxillo facial radiology.

[4]  J F Gravely,et al.  The Clinical Significance of Tracing Error in Cephalometry , 1974, British journal of orthodontics.

[5]  H. Gröndahl,et al.  On the dynamic range of different X-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems. , 1996, Dento maxillo facial radiology.

[6]  A Wenzel,et al.  Reliability of landmark recording on film and digital lateral cephalograms. , 1993, European journal of orthodontics.

[7]  A Wenzel,et al.  Influence of computerized information technologies on image quality in dental radiographs. , 1991, Tandlaegebladet.

[8]  S. Linder-Aronson,et al.  Reproducibility of cephalometric landmarks and errors of measurements of cephalometric cranial distances. , 1974, The Angle orthodontist.

[9]  A Jäger,et al.  Digital image processing techniques for cephalometric analysis. , 1991, Computers in biology and medicine.

[10]  A Richardson,et al.  An investigation into the reproducibility of some points, planes, and lines used in cephalometric analysis. , 1966, American journal of orthodontics.

[11]  D J Birnie,et al.  Digital Image Processing of Cephalometric Radiographs: A Preliminary Report , 1985, British journal of orthodontics.

[12]  U Welander,et al.  The effect of image quality on the identification of cephalometric landmarks. , 1978, The Angle orthodontist.

[13]  B W Gayler,et al.  Teleradiology: results of a field trial. , 1983, Radiology.

[14]  Sheldon Baumrind,et al.  The reliability of head film measurements , 1971 .

[15]  S Richmond,et al.  Digital imaging of cephalometric radiography, Part 1: Advantages and limitations of digital imaging. , 1996, The Angle orthodontist.

[16]  M. Sonoda,et al.  Computed radiography utilizing scanning laser stimulated luminescence. , 1983, Radiology.

[17]  E. Braunstein,et al.  Digital skeletal radiography. , 1992, AJR. American journal of roentgenology.

[18]  M Iikubo,et al.  Description of a new cephalostat and its performance. , 1975, Dento maxillo facial radiology.

[19]  B. Eppley,et al.  Computerized digital enhancement in craniofacial cephalometric radiography. , 1991, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[20]  A Richardson,et al.  A comparison of traditional and computerized methods of cephalometric analysis. , 1981, European journal of orthodontics.

[21]  S Baumrind,et al.  The reliability of head film measurements. 1. Landmark identification. , 1971, American journal of orthodontics.

[22]  M Sherriff,et al.  Sources of error in measurements from cephalometric radiographs. , 1986, European journal of orthodontics.

[23]  R. Greene,et al.  Single exposure simultaneous acquisition of digital and conventional radiographs utilizing unaltered dose. , 1988, European journal of radiology.

[24]  A R Cowen,et al.  Physical aspects of photostimulable phosphor computed radiography. , 1993, The British journal of radiology.

[25]  W J Houston,et al.  The analysis of errors in orthodontic measurements. , 1983, American journal of orthodontics.