Measurement of total blood flow in the normal human retina using Doppler Fourier-domain optical coherence tomography

Aim: To measure total retinal blood flow in normal human eyes using Doppler Fourier-domain optical coherence tomography (FD-OCT). Methods: 10 normal people aged 35 to 69 years were measured for the right eye using Doppler FD-OCT. Double circular scans around the optic nerve heads were used. Four pairs of circular scans that transected all retinal branch vessels were completed in 2 s. Total retinal blood flow was obtained by summing the flows in the branch veins. Measurements from the eight scans were averaged. Veins with diameters >33 μm were taken into account. Results: Total retinal blood flow could be measured in eight of 10 subjects: mean (SD) = 45.6 (3.8) μl/min (range 40.8 to 52.9 μl/min). The coefficient of variation for repeated measurements was 10.5%. Measured vein diameters ranged from 33.3 to 155.4 μm. The averaged flow speed was 19.3 (2.9) mm/s, which did not correlate with vessel diameter. There was no significant difference between flows in the superior and inferior retinal hemispheres. Conclusions: Double circular scanning using Doppler FD-OCT is a rapid and reproducible method to measure total retinal blood flow. These flow values are within the range previously established by laser Doppler flowmetry.

[1]  Richard B. Rosen,et al.  Retinal Blood Flow in the Normal Human Eye Using the Canon Laser Blood Flowmeter , 2002, Ophthalmic Research.

[2]  G T Feke,et al.  Blood flow in the normal human retina. , 1989, Investigative ophthalmology & visual science.

[3]  S. Zeger,et al.  Longitudinal data analysis using generalized linear models , 1986 .

[4]  C. Riva,et al.  Laser Doppler measurements of blood flow in capillary tubes and retinal arteries. , 1972, Investigative ophthalmology.

[5]  J. Duker,et al.  Imaging of macular diseases with optical coherence tomography. , 1995, Ophthalmology.

[6]  Teresa C. Chen,et al.  In vivo dynamic human retinal blood flow imaging using ultra-high-speed spectral domain optical Doppler tomography , 2003 .

[7]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991, LEOS '92 Conference Proceedings.

[8]  Carmen A. Puliafito,et al.  Automatic retinal blood flow calculation using spectral domain optical coherence tomography , 2007, SPIE BiOS.

[9]  J. Ware,et al.  Random-effects models for longitudinal data. , 1982, Biometrics.

[10]  R W Flower,et al.  Extraction of choriocapillaris hemodynamic data from ICG fluorescence angiograms. , 1993, Investigative ophthalmology & visual science.

[11]  B L Petrig,et al.  Blood velocity and volumetric flow rate in human retinal vessels. , 1985, Investigative ophthalmology & visual science.

[12]  J. Izatt,et al.  In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomography. , 1997, Optics letters.

[13]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[14]  Neha Khanduja,et al.  Spectral Domain-Optical Coherence Tomography , 2011, Definitions.

[15]  Joseph A Izatt,et al.  In vivo total retinal blood flow measurement by Fourier domain Doppler optical coherence tomography. , 2007, Journal of biomedical optics.

[16]  C. O'brien,et al.  A comparison of ocular blood flow in untreated primary open-angle glaucoma and ocular hypertension. , 1998, American journal of ophthalmology.

[17]  Geert Molenberghs,et al.  Random Effects Models for Longitudinal Data , 2010 .

[18]  Maciej Wojtkowski,et al.  Real-time measurement of in vitro flow by Fourier-domain color Doppler optical coherence tomography. , 2004, Optics letters.

[19]  A Hofman,et al.  Age-specific prevalence and causes of blindness and visual impairment in an older population: the Rotterdam Study. , 1998, Archives of ophthalmology.

[20]  Shuichi Makita,et al.  Quantitative retinal-blood flow measurement with three-dimensional vessel geometry determination using ultrahigh-resolution Doppler optical coherence angiography. , 2008, Optics letters.

[21]  M. Langham,et al.  A clinical procedure for the measurements of the ocular pulse-pressure relationship and the ophthalmic arterial pressure. , 1978, Experimental eye research.

[22]  J. Fujimoto,et al.  Optical coherence tomography: A new tool for glaucoma diagnosis , 1995, Current opinion in ophthalmology.

[23]  E. Stefánsson,et al.  The impact of ocular blood flow in glaucoma , 2002, Progress in Retinal and Eye Research.

[24]  J. Nelson,et al.  Characterization of fluid flow velocity by optical Doppler tomography. , 1995, Optics letters.

[25]  J. Izatt,et al.  Retinal blood flow measurement by circumpapillary Fourier domain Doppler optical coherence tomography. , 2008, Journal of biomedical optics.

[26]  B. Munoz,et al.  Diabetes and diabetic retinopathy in a Mexican-American population: Proyecto VER. , 2001, Diabetes care.

[27]  Yoko Ishii,et al.  New neuroretinal rim blood flow evaluation method combining Heidelberg retina flowmetry and tomography , 2001, The British journal of ophthalmology.

[28]  A. Harris Atlas of Ocular Blood Flow: Vascular Anatomy, Pathophysiology, and Metabolism , 2003 .