The purpose of this work was to develop a novel integrated radiofrequency and shim (RF/shim) coil array that can perform parallel reception and localized B0 shimming in the human brain with the same coils, thereby maximizing both the signal-to-noise ratio and shimming efficiency. A 32-channel receive-only head coil array was modified to enable both RF currents (for signal reception) and direct currents (for B0 shimming) to flow in individual coil elements. Its in vivo performance was assessed in the frontal brain region, which is affected by large susceptibility-induced B0 inhomogeneities. The coil modifications did not reduce their quality factor or signal-to-noise ratio. Axial B0 maps and echo-planar images acquired in vivo with direct currents optimized to shim specific slices showed substantially reduced B0 inhomogeneities and image distortions in the frontal brain region. The B0 root-mean-square error in the anterior half of the brain was reduced by 60.3% as compared to that obtained with second-order spherical harmonic shimming. These results demonstrate that the integrated RF/shim coil array can perform parallel reception and localized B0 shimming in the human brain and provide a much more effective shimming than conventional spherical harmonic shimming alone, without taking up additional space in the magnet bore and without compromising the signal-to-noise ratio or shimming performance.

[1]  Trong-Kha Truong,et al.  997 Integrated RF / Shim Coil Array for Parallel Reception and Localized B 0 Shimming in the Human Brain at 3 T , 2013 .

[2]  J. Polimeni,et al.  96‐Channel receive‐only head coil for 3 Tesla: Design optimization and evaluation , 2009, Magnetic resonance in medicine.

[3]  Christoph Juchem,et al.  Multicoil shimming of the mouse brain , 2011, Magnetic resonance in medicine.

[4]  L. Wald,et al.  A 64‐channel 3T array coil for accelerated brain MRI , 2013, Magnetic resonance in medicine.

[5]  Trong-Kha Truong,et al.  Integrated parallel reception, excitation, and shimming (iPRES) , 2013, Magnetic resonance in medicine.

[6]  D. Hoult,et al.  Magnet field profiling: Analysis and correcting coil design , 1984, Magnetic resonance in medicine.

[7]  Gary H Glover,et al.  Mitigation of susceptibility‐induced signal loss in neuroimaging using localized shim coils , 2005, Magnetic resonance in medicine.

[8]  Azma Mareyam,et al.  A 32 ch combined RF-shim brain array for efficient B 0 shimming and RF reception at 3 T , 2013 .

[9]  Trong-Kha Truong,et al.  Three-dimensional numerical simulations of susceptibility-induced magnetic field inhomogeneities in the human head. , 2002, Magnetic resonance imaging.

[10]  Stephan Biber,et al.  Design of a Local Shim Coil to Improve B 0 Homogeneity in the Cervical Spine Region , 2011 .

[11]  A M Blamire,et al.  Dynamic shim updating: A new approach towards optimized whole brain shimming , 1996, Magnetic resonance in medicine.

[12]  William B Handler,et al.  A new approach to shimming: The dynamically controlled adaptive current network , 2014, Magnetic resonance in medicine.

[13]  J. Goodship,et al.  Centiles for adult head circumference. , 1992, Archives of disease in childhood.

[14]  D. Rothman,et al.  Dynamic multi-coil shimming of the human brain at 7 T. , 2011, Journal of magnetic resonance.