Semi-Automatic Basket Catheter Reconstruction from Two X-Ray Views

Ablation guided by focal impulse and rotor mapping (FIRM) is a novel treatment option for atrial fibrillation, a frequent heart arrhythmia. This procedure is performed minimally invasively and at least partially under fluoroscopic guidance. It involves a basket catheter comprising 64 electrodes. The 3-D position of these electrodes is important during treatment. We propose a novel model-based method for 3-D reconstruction of this catheter using two X-ray images taken from different views. Our approach requires only little user interaction. An evaluation of the method found that the electrodes of the basket catheter can be reconstructed with a median error of 1.5 mm for phantom data and 3.4 mm for clinical data.

[1]  R. Hartley Triangulation, Computer Vision and Image Understanding , 1997 .

[2]  Wouter-Jan Rappel,et al.  Treatment of atrial fibrillation by the ablation of localized sources: CONFIRM (Conventional Ablation for Atrial Fibrillation With or Without Focal Impulse and Rotor Modulation) trial. , 2012, Journal of the American College of Cardiology.

[3]  Tony Lindeberg,et al.  Feature Detection with Automatic Scale Selection , 1998, International Journal of Computer Vision.

[4]  Marie-Odile Berger,et al.  Three-dimensional curvilinear device reconstruction from two fluoroscopic views , 2015, Medical Imaging.

[5]  Petia Radeva,et al.  3D curve reconstruction by biplane snakes , 2000, Proceedings 15th International Conference on Pattern Recognition. ICPR-2000.

[6]  Carsten Steger,et al.  An Unbiased Detector of Curvilinear Structures , 1998, IEEE Trans. Pattern Anal. Mach. Intell..

[7]  Rebecca Fahrig,et al.  Accuracy Assessment of Catheter Guidance Technology in Electrophysiology Procedures , 2014, Journal of cardiovascular electrophysiology.

[8]  Alexandru Tupan,et al.  Triangulation , 1997, Comput. Vis. Image Underst..

[9]  Joachim Hornegger,et al.  Semi-automatic Catheter Reconstruction from Two Views , 2012, MICCAI.

[10]  Christopher Piorkowski,et al.  EnSite Velocity™ cardiac mapping system: a new platform for 3D mapping of cardiac arrhythmias , 2010, Expert review of medical devices.

[11]  Alejandro F. Frangi,et al.  Muliscale Vessel Enhancement Filtering , 1998, MICCAI.

[12]  Andreas K. Maier,et al.  Robust Vessel Segmentation in Fundus Images , 2013, Int. J. Biomed. Imaging.

[13]  Timothy F. Cootes,et al.  Active Shape Models-Their Training and Application , 1995, Comput. Vis. Image Underst..