A Lightweight Deep Learning Network on a System-on-Chip for Wearable Ultrasound Bladder Volume Measurement Systems: Preliminary Study

Bladder volume assessments are crucial for managing urinary disorders. Ultrasound imaging (US) is a preferred noninvasive, cost-effective imaging modality for bladder observation and volume measurements. However, the high operator dependency of US is a major challenge due to the difficulty in evaluating ultrasound images without professional expertise. To address this issue, image-based automatic bladder volume estimation methods have been introduced, but most conventional methods require high-complexity computing resources that are not available in point-of-care (POC) settings. Therefore, in this study, a deep learning-based bladder volume measurement system was developed for POC settings using a lightweight convolutional neural network (CNN)-based segmentation model, which was optimized on a low-resource system-on-chip (SoC) to detect and segment the bladder region in ultrasound images in real time. The proposed model achieved high accuracy and robustness and can be executed on the low-resource SoC at 7.93 frames per second, which is 13.44 times faster than the frame rate of a conventional network with negligible accuracy drawbacks (0.004 of the Dice coefficient). The feasibility of the developed lightweight deep learning network was demonstrated using tissue-mimicking phantoms.

[1]  Y. Cho,et al.  Deep-learning segmentation of ultrasound images for automated calculation of the hydronephrosis area to renal parenchyma ratio , 2022, Investigative and clinical urology.

[2]  Masashi Kato,et al.  Feasibility of the Lilium α-200 portable ultrasound bladder scanner for accurate bladder volume measurement , 2020, Investigative and clinical urology.

[3]  H. Sax,et al.  Impact of an evidence-based intervention on urinary catheter utilization, associated process indicators, and infectious and non-infectious outcomes. , 2020, The Journal of hospital infection.

[4]  Gang Yu,et al.  BiSeNet V2: Bilateral Network with Guided Aggregation for Real-Time Semantic Segmentation , 2020, International Journal of Computer Vision.

[5]  H. Sanada,et al.  Development and evaluation of automated ultrasonographic detection of bladder diameter for estimation of bladder urine volume , 2019, PloS one.

[6]  Kuan-Ta Chen,et al.  Automation of the kidney function prediction and classification through ultrasound-based kidney imaging using deep learning , 2019, npj Digital Medicine.

[7]  I. Tzeng,et al.  Portable Bladder Ultrasound Reduces Incidence of Urinary Tract Infection and Shortens Hospital Length of Stay in Patients With Acute Ischemic Stroke , 2018, The Journal of cardiovascular nursing.

[8]  Ghassan Hamarneh,et al.  Combo Loss: Handling Input and Output Imbalance in Multi-Organ Segmentation , 2018, Comput. Medical Imaging Graph..

[9]  Loïc Le Folgoc,et al.  Attention U-Net: Learning Where to Look for the Pancreas , 2018, ArXiv.

[10]  Mark Sandler,et al.  MobileNetV2: Inverted Residuals and Linear Bottlenecks , 2018, 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition.

[11]  Qiang Zheng,et al.  Transfer learning for diagnosis of congenital abnormalities of the kidney and urinary tract in children based on ultrasound imaging data , 2017, 2018 IEEE 15th International Symposium on Biomedical Imaging (ISBI 2018).

[12]  Bo Chen,et al.  Quantization and Training of Neural Networks for Efficient Integer-Arithmetic-Only Inference , 2017, 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition.

[13]  Gang Sun,et al.  Squeeze-and-Excitation Networks , 2017, 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition.

[14]  M. Cho,et al.  Accuracy and precision of a new portable ultrasound scanner, the Biocon-700, in residual urine volume measurement , 2017, International Urogynecology Journal.

[15]  François Chollet,et al.  Xception: Deep Learning with Depthwise Separable Convolutions , 2016, 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR).

[16]  P. Rosier,et al.  Measurement of post‐void residual urine , 2016, Neurourology and urodynamics.

[17]  Thomas Brox,et al.  U-Net: Convolutional Networks for Biomedical Image Segmentation , 2015, MICCAI.

[18]  Jimmy Ba,et al.  Adam: A Method for Stochastic Optimization , 2014, ICLR.

[19]  S. Saint,et al.  Reducing unnecessary urinary catheter use and other strategies to prevent catheter-associated urinary tract infection: an integrative review , 2013, BMJ quality & safety.

[20]  Seung-June Oh,et al.  Accuracy of post‐void residual urine volume measurement using a portable ultrasound bladder scanner with real‐time pre‐scan imaging , 2011, Neurourology and urodynamics.

[21]  Daniela M. Darrah,et al.  Postoperative urinary retention. , 2009, Anesthesiology clinics.

[22]  F. Kendel,et al.  Post-void residual urine as a predictor of urinary tract infection--is there a cutoff value in asymptomatic men? , 2009, The Journal of urology.

[23]  L. Bih,et al.  Application of Portable Ultrasound Scanners in the Measurement of Post-Void Residual Urine , 2005, The journal of nursing research : JNR.

[24]  Elizabeth R Stevens Bladder ultrasound: avoiding unnecessary catheterizations. , 2005, Medsurg nursing : official journal of the Academy of Medical-Surgical Nurses.

[25]  L. Bih,et al.  Bladder shape impact on the accuracy of ultrasonic estimation of bladder volume. , 1998, Archives of physical medicine and rehabilitation.

[26]  R. Bruskewitz,et al.  Value of postvoid residual urine determination in evaluation of prostatism. , 1982, Urology.

[27]  D. Roth,et al.  Measurement of Postvoid Residual Urine with Portable Transabdominal Bladder Ultrasound Scanner and Urethral Catheterization , 2000, International Urogynecology Journal.

[28]  H. Drutz,et al.  The Accuracy of Portable Abdominal Ultrasound Equipment in Measuring Postvoid Residual Volume , 1999, International Urogynecology Journal.