Field Performance of Heat Pump Water Heaters in the Northeast

Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads. Steven Winter Associates, Inc. embarked on one of the first in situ studies of these newly released HPWH products through a partnership with two sponsoring electric utility companies, National Grid and NSTAR, and one sponsoring energy efficiency service program administrator, Cape Light Compact. Recent laboratory studies have measured performance of HPWHs under various operating conditions, but publically available field studies have not been as available. This evaluation attempts to provide publicly available field data on new HPWHs by monitoring the performance of three recently released products (General Electric GeoSpring(TM), A.O. Smith Voltex(R), and Stiebelmore » Eltron Accelera(R) 300). Fourteen HPWHs were installed in Massachusetts and Rhode Island and monitored for over a year. Of the 14 units, ten were General Electric models (50 gallon units), two were Stiebel Eltron models (80 gallon units), and two were A.O. Smith models (one 60-gallon and one 80-gallon unit).« less

[1]  Pacific Gas Laboratory Evaluation and Field Testing of Residential Heat Pump Water Heaters , 2010 .

[2]  S. F. Actory,et al.  Personal correspondence , 1997 .

[3]  Dane Christensen,et al.  Heat Pump Water Heater Technology Assessment Based on Laboratory Research and Energy Simulation Models , 2012 .

[4]  Bg Ashdown Heat Pump Water Heater Technology: Experiences of Residential Consumers and Utilities , 2004 .

[5]  Dane Christensen,et al.  Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters , 2014 .

[7]  John Dieckmann,et al.  Heat Pump Water Heaters , 2005 .

[8]  P. Torcellini,et al.  Source Energy and Emission Factors for Energy Use in Buildings (Revised) , 2007 .

[9]  Kenneth A. Bollen,et al.  Regression Diagnostics , 1985 .

[10]  Ernest Orlando Lawrence Heat Pump Water Heaters and American Homes: A Good Fit? , 2010 .

[11]  S. Bodzin Air-to-water heat pumps for the home , 1997 .

[12]  John J. Tomlinson All Pumped Up New heat pump water heaters consume half the energy of conventional electric-resistance ones. , 2002 .

[13]  R. Judkoff,et al.  Method for Determining Optimal Residential Energy Efficiency Retrofit Packages , 2011 .

[14]  Omar Abdelaziz,et al.  Development of Environmentally Benign Heat Pump Water Heaters for the US Market , 2012 .

[15]  Carl R. Shapiro,et al.  Measure Guideline: Heat Pump Water Heaters in New and Existing Homes , 2012 .

[16]  Danny S. Parker,et al.  Side-by-Side Testing of Water Heating Systems: Results from the 2010 - 2011 Evaluation , 2013 .

[17]  End Use Annual energy outlook : with projections to ... , 1983 .

[18]  Robert Hendron,et al.  Building America House Simulation Protocols , 2010 .