A translational couch technique for total body irradiation.

We have constructed a computer controlled translational couch to administer total body irradiation reproducibly and safely. The system has replaced the previous stationary anterior‐posterior technique in our institution and 30 plus patients have been treated with it so far. In this technique, patients comfortably lie on a couch in supine and prone positions and are transported slowly through a narrow beam with the gantry in an upright position. Dose to the patient is determined by the couch velocity that is calculated based on physical parameters such as patient's dimensions, beam geometry, and machine dose rate. In our design, the couch velocity is continuously updated to compensate for machine dose rate fluctuations. The translational couch technique provides better dose uniformity within the patient compared to fixed beam techniques, and allows a more precise shielding block placement for organs at risk. At the same time, it presents a special challenge for dosimetry calculations. A dosimetry parameter is introduced that converts the moving beam output to the fixed beam output factor. Based on this factor, a simple dosimetry calculation method has been developed that takes advantage of conventional dosimetry parameters, eliminating extensive dosimetry measurements. Multiple point dose measurements within a phantom confirmed the validity of the calculation method. PACS number(s): 87.53.–j, 87.66.–a

[1]  L Papiez,et al.  The clinical application of dynamic shielding and imaging in moving table total body irradiation. , 1999, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[2]  R. Valicenti,et al.  Changes in the size and location of kidneys from the supine to standing positions and the implications for block placement during total body irradiation. , 1999, International journal of radiation oncology, biology, physics.

[3]  U Quast,et al.  Physical treatment planning of total-body irradiation: patient translation and beam-zone method. , 1985, Medical physics.

[4]  M. Chrétien,et al.  A variable speed translating couch technique for total body irradiation. , 2000, Medical physics.

[5]  B Umek,et al.  Total body irradiation with translation method. , 1996, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[6]  A. Barrett,et al.  Total body irradiation before bone marrow transplantation: a review. , 1982, Clinical radiology.

[7]  P Genest,et al.  A translating-bed technique for total-body irradiation. , 1994, Physics in medicine and biology.

[8]  J. J. Broerse,et al.  Techniques applied for total body irradiation. , 1990, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  E. El-Khatib,et al.  Total body irradiation with a sweeping 60Cobalt beam. , 1995, International journal of radiation oncology, biology, physics.

[10]  W. Hanson,et al.  Verification of total body photon irradiation dosimetry techniques. , 1988, Medical Physics (Lancaster).

[11]  D P Fontenla,et al.  Total body irradiation with an arc and a gravity-oriented compensator. , 1997, International journal of radiation oncology, biology, physics.

[12]  G. Glasgow The dosimetry of fixed, single source hemibody and total body irradiators. , 1982, Medical physics.

[13]  J Scrimger,et al.  Development of a translating bed for total body irradiation. , 1988, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.