Improved Tumor Detection via Quantitative Microwave Breast Imaging Using Eigenfunction-Based Prior

A multistage algorithm for quantitative microwave breast imaging is presented which utilizes the eigenfunction-based reconstruction of the complex-valued permittivity as prior information. The eigenfunction-based reconstruction is obtained from a single-frequency non-iterative microwave inversion technique that uses the eigenfunctions of the Helmholtz operator, in a resonant conductive enclosure, as the expansion basis. The low-resolution eigenfunction-based reconstruction is incorporated into the Contrast Source Inversion technique as an inhomogeneous numerical background. The use of this prior information improves the stability of the inversion algorithm, and results in better detectability of tumors. The multistage algorithm's performance is demonstrated by applying it to synthetic data obtained from three 2D MRI-derived anthropomorphic breast models with various densities, and shapes. The algorithm's efficacy in tumor detection is assessed by investigating detection results using prior information obtained with the number of eigenfunction in the expansion basis truncated with three different values. Numerical experiments are performed using four different frequencies. The main advantage of obtaining prior information using this method, as opposed e.g. in using radar or ultrasound derived prior, is that it utilizes the same microwave set-up, and only microwave interrogating fields.

[1]  Amir H. Golnabi,et al.  3-D Microwave Tomography Using the Soft Prior Regularization Technique: Evaluation in Anatomically Realistic MRI-Derived Numerical Breast Phantoms , 2019, IEEE Transactions on Biomedical Engineering.

[3]  C. Curtis,et al.  Microwave Breast Imaging With a Monostatic Radar-Based System: A Study of Application to Patients , 2013, IEEE Transactions on Microwave Theory and Techniques.

[4]  Susan C. Hagness,et al.  High-Resolution Microwave Breast Imaging Using a 3-D Inverse Scattering Algorithm With a Variable-Strength Spatial Prior Constraint , 2017 .

[5]  Joe LoVetri,et al.  Regularization Approaches for a Non-Iterative Eigenfunction-Based Electromagnetic Inversion Algorithm , 2018, 2018 18th International Symposium on Antenna Technology and Applied Electromagnetics (ANTEM).

[6]  E. Fear,et al.  Incorporation of Ultrasonic Prior Information for Improving Quantitative Microwave Imaging of Breast , 2019, IEEE Journal on Multiscale and Multiphysics Computational Techniques.

[7]  Joe LoVetri,et al.  Modeling Error and Calibration Techniques for a Faceted Metallic Chamber for Magnetic Field Microwave Imaging , 2017, IEEE Transactions on Microwave Theory and Techniques.

[8]  Maurizio Bozzi,et al.  Dielectric Properties Characterization From 0.5 to 50 GHz of Breast Cancer Tissues , 2017, IEEE Transactions on Microwave Theory and Techniques.

[9]  Martin O’Halloran,et al.  Microwave Breast Imaging: Clinical Advances and Remaining Challenges , 2018, IEEE Transactions on Biomedical Engineering.

[10]  M. Lindstrom,et al.  A large-scale study of the ultrawideband microwave dielectric properties of normal, benign and malignant breast tissues obtained from cancer surgeries , 2007, Physics in medicine and biology.

[11]  J. Bolomey Crossed Viewpoints on Microwave-Based Imaging for Medical Diagnosis: From Genesis to Earliest Clinical Outcomes , 2018 .

[12]  Elise Fear,et al.  Anthropomorphic breast model repository for research and development of microwave breast imaging technologies , 2018, Scientific Data.

[13]  Joe LoVetri,et al.  Proof-of-Concept of the Incorporation of Ultrasound-Derived Structural Information Into Microwave Radar Imaging , 2018, IEEE Journal on Multiscale and Multiphysics Computational Techniques.

[14]  A. Worster,et al.  Understanding receiver operating characteristic (ROC) curves. , 2006, CJEM.

[15]  C. Gilmore,et al.  Finite-element contrast source inversion method for microwave imaging , 2010 .