Correlation of mass spectrometry identified bacterial biomarkers from a fielded pyrolysis-gas chromatography-ion mobility spectrometry biodetector with the microbiological gram stain classification scheme.

A pyrolysis-gas chromatography-ion mobility spectrometry (Py-GC-IMS) briefcase system has been shown to detect and classify deliberately released bioaerosols in outdoor field scenarios. The bioaerosols included Gram-positive and Gram-negative bacteria, MS-2 coliphage virus, and ovalbumin protein species. However, the origin and structural identities of the pyrolysate peaks in the GC-IMS data space, their microbiological information content, and taxonomic importance with respect to biodetection have not been determined. The present work interrogates the identities of the peaks by inserting a time-of-flight mass spectrometry system in parallel with the IMS detector through a Tee connection in the GC module. Biological substances producing ion mobility peaks from the pyrolysis of microorganisms were identified by their GC retention time, matching of their electron ionization mass spectra with authentic standards, and the National Institutes for Standards and Technology mass spectral database. Strong signals from 2-pyridinecarboxamide were identified in Bacillus samples including Bacillus anthracis, and its origin was traced to the cell wall peptidoglycan macromolecule. 3-Hydroxymyristic acid is a component of lipopolysaccharides in the cell walls of Gram-negative organisms. The Gram-negative Escherichia coli organism showed significant amounts of 3-hydroxymyristic acid derivatives and degradation products in Py-GC-MS analyses. Some of the fatty acid derivatives were observed in very low abundance in the ion mobility spectra, and the higher boiling lipid species were absent. Evidence is presented that the Py-GC-ambient temperature and pressure-IMS system generates and detects bacterial biochemical information that can serve as components of a biological classification scheme directly correlated to the Gram stain reaction in microorganism taxonomy.

[1]  P. Simmonds,et al.  A pyrolysis gas chromatography mass spectrometry study of the actinomycete Streptomyces longisporoflavus , 1975 .

[2]  K. Voorhees,et al.  An investigation into the Curie-point pyrolysis-mass spectrometry of glycyl dipeptides , 1996 .

[3]  Riccardo Leardi,et al.  Application of three-way principal component analysis to the evaluation of two-dimensional maps in proteomics. , 2003, Journal of proteome research.

[4]  J. Boon,et al.  Amino acid sequence information in proteins and complex proteinaceous material revealed by pyrolysis-capillary gas chromatography-low and high resolution mass spectrometry , 1987 .

[5]  Pieter M. Kroonenberg,et al.  Three-mode principal component analysis : theory and applications , 1983 .

[6]  S. Morgan,et al.  2-Butenoic acid, a chemical marker for poly-β-hydroxybutyrate identified by pyrolysis—gas chromatography / mass spectrometry in analyses of whole microbial cells , 1991 .

[7]  S. Morgan,et al.  Gas chromatographic-mass spectrometric determination of muramic acid content and pyrolysis profiles for a group of gram-positive and gram-negative bacteria. , 1985, The Analyst.

[8]  Gary A. Eiceman,et al.  Advances in Ion Mobility Spectrometry: 1980–1990 , 1991 .

[9]  J. A. Schultz,et al.  Lipid/peptide/nucleotide separation with MALDI-ion mobility-TOF MS. , 2004, Analytical chemistry.

[10]  K. Voorhees,et al.  An investigation of dipeptides containing polar and nonpolar side groups by curie-point pyrolysis tandem mass spectrometry , 1992, Journal of the American Society for Mass Spectrometry.

[11]  G. Eiceman,et al.  Ion Mobility Spectrometry: Arriving on Site and Moving beyond a Low Profile , 1999, Applied spectroscopy.

[12]  Y. Mechref,et al.  Development of high-sensitivity ion trap ion mobility spectrometry time-of-flight techniques: a high-throughput nano-LC-IMS-TOF separation of peptides arising from a Drosophila protein extract. , 2003, Analytical chemistry.

[13]  A. Snyder,et al.  Field detection and identification of a bioaerosol suite by pyrolysis-gas chromatography-ion mobility spectrometry* , 2001 .

[14]  T. Hadfield,et al.  A rapid approach for the detection of dipicolinic acid in bacterial spores using pyrolysis/mass spectrometry. , 1996, Rapid communications in mass spectrometry : RCM.

[15]  A. Snyder,et al.  Portable Hand-Held Gas Chromatography/Ion Mobility Spectrometry Device , 1993 .

[16]  M. Bowers,et al.  Evidence from Ion Chromatography Experiments That Met-Cars Are Hollow Cage Clusters , 1995, Science.

[17]  A. Snyder,et al.  Detection of gram-negative Erwinia herbicola outdoor aerosols with pyrolysis–gas chromatography/ion-mobility spectrometry , 2000 .

[18]  A P Snyder,et al.  Optimization of quartz tube pyrolysis atmospheric pressure ionization mass spectrometry for the generation of bacterial biomarkers. , 2001, Rapid communications in mass spectrometry : RCM.

[19]  G. Smith,et al.  Gas chromatographic–mass spectrometric analysis of the Curie-point pyrolysis products of some dipeptides and their diketopiperazine , 1988 .

[20]  J. Boon,et al.  Analytical pyrolysis of carbohydrates: I. Chemical interpretation of matrix influences on pyrolysis-mass spectra of amylose using pyrolysis-gas chromatography-mass spectrometry , 1983 .

[21]  G. Gould,et al.  The Bacterial Spore , 1984 .

[22]  R. Marchessault,et al.  Pyrolysis of bacterial polyalkanoates , 1981 .

[23]  A. Snyder,et al.  Orthogonal analysis of mass and spectral based technologies for the field detection of bioaerosols , 2004 .

[24]  B. Ruotolo,et al.  Coupling high-pressure MALDI with ion mobility/orthogonal time-of-flight mass spectrometry. , 2000, Analytical chemistry.

[25]  K. Voorhees,et al.  Amino acid and oligopeptide analysis using Curie-point pyrolysis mass spectrometry with in-situ thermal hydrolysis and methylation: mechanistic considerations , 1998 .

[26]  Shin Tsuge,et al.  High-resolution pyrolysis-gas chromatography of proteins and related materials , 1985 .

[27]  Kent J. Voorhees,et al.  An investigation of the pyrolysis of oligopeptides by Curie-point pyrolysis—tandem mass spectrometry , 1994 .

[28]  M. Bowers,et al.  Gas-Phase Ion Chromatography: Transition Metal State Selection and Carbon Cluster Formation , 1993, Science.

[29]  J. McLean,et al.  Sub-femtomole peptide detection in ion mobility-time-of-flight mass spectrometry measurements. , 2003, Journal of Proteome Research.

[30]  Sidney N. Thornton,et al.  Detection of the picolinic acid biomarker in Bacillus spores using a potentially field‐portable pyrolysis—gas chromatography—ion mobility spectrometry system , 1996 .

[31]  T. Beveridge,et al.  Cellular incorporation of poly-beta-hydroxybutyrate into plasma membranes of Escherichia coli and Azotobacter vinelandii alters native membrane structure. , 1987, Canadian Journal of Microbiology (print).

[32]  D. Clemmer,et al.  Ion trap/ion mobility/quadrupole/time-of-flight mass spectrometry for peptide mixture analysis. , 2001, Analytical chemistry.

[33]  R. B. Turner Transitioning analytical instrumentation from the laboratory to harsh environments , 2002 .

[34]  M. Jarrold,et al.  Ion mobility studies of metal-coated fullerenes , 1999 .

[35]  R. Reusch,et al.  D-(-)-poly-beta-hydroxybutyrate in membranes of genetically competent bacteria , 1983, Journal of bacteriology.

[36]  Giuseppe Chiavari,et al.  Pyrolysis—gas chromatography/mass spectrometry of amino acids , 1992 .