Validation of a high-resolution, phase contrast cardiovascular magnetic resonance sequence for evaluation of flow in coronary artery bypass grafts.

The aim was to validate a magnetic resonance high-resolution, phase-contrast sequence for quantifying flow in small and large vessels and to demonstrate its feasibility to measure flow in coronary artery bypass grafts. A breathhold, echo planar imaging (EPI) sequence was developed and validated in a flow phantom using a fast field echo (FFE) sequence as reference. In 17 volunteers aortic flow was measured using both sequences. In 5 patients flow in the left internal mammary artery (LIMA) and aorta was measured at rest and during adenosine stress, and coronary flow reserve (CFR) was calculated; in 7 patients, vein graft flow velocity was measured. In the flow phantom measurements, the EPI sequence yielded an excellent correlation with the FFE sequence (r = 0.99; p < 0.001 for all parameters). In healthy volunteers, aortic volume flow correlated well (r = 0.88; p < 0.01), with a minor overestimation. It was feasible to measure flow velocity in the LIMA and vein grafts of the 12 patients. The high-resolution, breathhold cardiovascular magnetic resonance velocity-encoded sequence correlated well with a free-breathing, FFE sequence in a flow phantom and in the aortae of healthy volunteers. Using the EPI sequence, it is feasible to measure flow velocity in both LIMA and vein grafts, and in the aorta.

[1]  R. Wilson,et al.  Effects of adenosine on human coronary arterial circulation. , 1990, Circulation.

[2]  R. J. van der Geest,et al.  Noninvasive evaluation of aortocoronary bypass grafts with magnetic resonance flow mapping. , 1995, The American journal of cardiology.

[3]  D Meier,et al.  Quantitative flow measurements on phantoms and on blood vessels with MR , 1988, Magnetic resonance in medicine.

[4]  C. Meier,et al.  Cardiovascular flow measurement with phase-contrast MR imaging: basic facts and implementation. , 2002, Radiographics : a review publication of the Radiological Society of North America, Inc.

[5]  E. E. van der Wall,et al.  Pulmonary Regurgitation in the Late Postoperative Follow‐up of Tetralogy of Fallot Volumetric Quantitation by Nuclear Magnetic Resonance Velocity Mapping , 1993, Circulation.

[6]  D. Parker,et al.  Accuracy of phase‐contrast flow measurements in the presence of partial‐volume effects , 1993, Journal of magnetic resonance imaging : JMRI.

[7]  J Wouter Jukema,et al.  Value of Magnetic Resonance Imaging for the Noninvasive Detection of Stenosis in Coronary Artery Bypass Grafts and Recipient Coronary Arteries , 2003, Circulation.

[8]  Jeroen J. Bax,et al.  Blood flow in coronary artery bypass vein grafts: volume versus velocity at cardiovascular MR imaging. , 2004, Radiology.

[9]  A. Fenster,et al.  Computer‐controlled flow simulator for MR flow studies , 1992, Journal of magnetic resonance imaging : JMRI.

[10]  P Boesiger,et al.  Visualization and quantification of the human blood flow by magnetic resonance imaging. , 1992, Journal of biomechanics.

[11]  A. Zwinderman,et al.  Vein graft function improvement after percutaneous intervention: evaluation with MR flow mapping. , 2003, Radiology.

[12]  T. Akasaka,et al.  Flow capacity of internal mammary artery grafts: early restriction and later improvement assessed by Doppler guide wire. Comparison with saphenous vein grafts. , 1995, Journal of the American College of Cardiology.

[13]  E. Topol,et al.  Our preoccupation with coronary luminology. The dissociation between clinical and angiographic findings in ischemic heart disease. , 1995, Circulation.

[14]  A. Fenster,et al.  Computer-controlled positive displacement pump for physiological flow simulation , 2006, Medical and Biological Engineering and Computing.

[15]  R J van der Geest,et al.  Automated measurement of volume flow in the ascending aorta using MR velocity maps: evaluation of inter- and intraobserver variability in healthy volunteers. , 1998, Journal of computer assisted tomography.

[16]  C. White,et al.  Does visual interpretation of the coronary arteriogram predict the physiologic importance of a coronary stenosis? , 1984, The New England journal of medicine.

[17]  C. Visser,et al.  Value of magnetic resonance imaging in assessing patency and function of coronary artery bypass grafts. An angiographically controlled study. , 1996, Circulation.

[18]  J. Debatin,et al.  MR characterization of blood flow in native and grafted internal mammary arteries , 1993, Journal of magnetic resonance imaging : JMRI.

[19]  M. Fenchel,et al.  Perioperative monitoring of flow and patency in native and grafted internal mammary arteries using a combined MR protocol. , 2005, The British journal of radiology.

[20]  C. Higgins,et al.  Breath‐hold MR measurements of blood flow velocity in internal mammary arteries and coronary artery bypass grafts , 1996, Journal of magnetic resonance imaging : JMRI.

[21]  Jeroen J. Bax,et al.  Real-time MR imaging of aortic flow: influence of breathing on left ventricular stroke volume in chronic obstructive pulmonary disease. , 2003, Radiology.

[22]  M. Viergever,et al.  MR phase‐contrast flow measurement with limited spatial resolution in small vessels: Value of model‐based image analysis , 1999, Magnetic resonance in medicine.

[23]  R J van der Geest,et al.  Quantification in cardiac MRI , 1999, Journal of magnetic resonance imaging : JMRI.

[24]  K. Takeda,et al.  Effect of breath holding on blood flow measurement using fast velocity encoded cine MRI , 2001, Magnetic resonance in medicine.

[25]  J. Bronzwaer,et al.  Assessment of coronary artery bypass graft disease using cardiovascular magnetic resonance determination of flow reserve. , 2002, Journal of the American College of Cardiology.

[26]  T Shimono,et al.  Mr flow measurement in the internal mammary artery-to-coronary artery bypass graft: comparison with graft stenosis at radiographic angiography. , 2001, Radiology.

[27]  D N Firmin,et al.  The application of phase shifts in NMR for flow measurement , 1990, Magnetic resonance in medicine.

[28]  Y. Louagie,et al.  Functional evaluation of internal mammary artery bypass grafts in the early and late postoperative periods. , 1995, Journal of the American College of Cardiology.