Predicting kinetics using musculoskeletal modeling and inertial motion capture

Inverse dynamic analysis using musculoskeletal modeling is a powerful tool, which is utilized in a range of applications to estimate forces in ligaments, muscles, and joints, non-invasively. To date, the conventional input used in this analysis is derived from optical motion capture (OMC) and force plate (FP) systems, which restrict the application of musculoskeletal models to gait laboratories. To address this problem, we propose a musculoskeletal model, capable of estimating the internal forces based solely on inertial motion capture (IMC) input and a ground reaction force and moment (GRF&M) prediction method. We validated the joint angle and kinetic estimates of the lower limbs against an equally constructed musculoskeletal model driven by OMC and FP system. The sagittal plane joint angles of ankle, knee, and hip presented excellent Pearson correlations (\rho = 0.95, 0.99, and 0.99, respectively) and root-mean-squared differences (RMSD) of 4.1 $\pm$ 1.3$\circ$, 4.4 $\pm$ 2.0$\circ$, and 5.7 $\pm$ 2.1$\circ$, respectively. The GRF&M predicted using IMC input were found to have excellent correlations for three components (vertical:\rho = 0.97, RMSD=9.3 $\pm$ 3.0 %BW, anteroposterior: \rho = 0.91, RMSD=5.5 $\pm$ 1.2 %BW, sagittal: \rho = 0.91, RMSD=1.6 $\pm$ 0.6 %BW*BH), and strong correlations for mediolateral (\rho = 0.80, RMSD=2.1 $\pm$ 0.6%BW ) and transverse (\rho = 0.82, RMSD=0.2 $\pm$ 0.1 %BW*BH). The proposed IMC-based method removes the complexity and space-restrictions of OMC and FP systems and could enable applications of musculoskeletal models in either monitoring patients during their daily lives or in wider clinical practice.

[1]  Michael A. Sprague,et al.  Spectral elements and field separation for an acoustic fluid subject to cavitation , 2003 .

[2]  John H. Challis,et al.  The Variability in Running Gait Caused by Force Plate Targeting , 2001 .

[3]  Walter Herzog,et al.  Model-based estimation of muscle forces exerted during movements. , 2007, Clinical biomechanics.

[4]  P. Veltink,et al.  Ambulatory measurement of ground reaction forces , 2005 .

[5]  W A Rowe,et al.  Limits of body mass index to detect obesity and predict body composition. , 2001, Nutrition.

[6]  H. Koopman,et al.  Prediction of ground reaction forces and moments during various activities of daily living. , 2014, Journal of biomechanics.

[7]  Peter H. Veltink,et al.  Influence of the instrumented force shoe on gait pattern in patients with osteoarthritis of the knee , 2011, Medical & Biological Engineering & Computing.

[8]  Richard Taylor Interpretation of the Correlation Coefficient: A Basic Review , 1990 .

[9]  F C T van der Helm,et al.  Use of pressure insoles to calculate the complete ground reaction forces. , 2004, Journal of biomechanics.

[10]  Ahnryul Choi,et al.  Ground reaction forces predicted by using artificial neural network during asymmetric movements , 2013 .

[11]  P. Veltink,et al.  Compensation of magnetic disturbances improves inertial and magnetic sensing of human body segment orientation , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[12]  John Rasmussen,et al.  A generic detailed rigid-body lumbar spine model. , 2007, Journal of biomechanics.

[13]  H. Hatze The fundamental problem of myoskeletal inverse dynamics and its implications. , 2002, Journal of biomechanics.

[14]  Chris T M Baten,et al.  Driving a musculoskeletal model with inertial and magnetic measurement units , 2015, Computer methods in biomechanics and biomedical engineering.

[15]  Qingguo Li,et al.  Concurrent validation of Xsens MVN measurement of lower limb joint angular kinematics , 2013, Physiological measurement.

[16]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 1: theoretical background. , 2005, Gait & posture.

[17]  K Aminian,et al.  Ambulatory assessment of 3D ground reaction force using plantar pressure distribution. , 2010, Gait & posture.

[18]  D. Roetenberg,et al.  Xsens MVN: Full 6DOF Human Motion Tracking Using Miniature Inertial Sensors , 2009 .

[19]  B. Koopman,et al.  A subject-specific musculoskeletal modeling framework to predict in vivo mechanics of total knee arthroplasty. , 2015, Journal of biomechanical engineering.

[20]  M. Damsgaard,et al.  Kinematic analysis of over-determinate biomechanical systems , 2009, Computer methods in biomechanics and biomedical engineering.

[21]  F. V. D. van der Helm,et al.  Inertia and muscle contraction parameters for musculoskeletal modelling of the shoulder mechanism. , 1991, Journal of biomechanics.

[22]  Musa L Audu,et al.  Experimental verification of a computational technique for determining ground reactions in human bipedal stance. , 2007, Journal of biomechanics.

[23]  H. J. M. Hanley,et al.  Experimental Verification of the , 1965 .

[24]  Ahnryul Choi,et al.  Prediction of ground reaction forces during gait based on kinematics and a neural network model. , 2013, Journal of biomechanics.

[25]  Peter H. Veltink,et al.  Ambulatory Assessment of Ankle and Foot Dynamics , 2007, IEEE Transactions on Biomedical Engineering.

[26]  K. An,et al.  Parameters for modeling the upper extremity. , 1997, Journal of biomechanics.

[27]  Jian Yang,et al.  A musculoskeletal model driven by dual Microsoft Kinect Sensor data , 2017, Multibody System Dynamics.

[28]  R. Riemer,et al.  Uncertainties in inverse dynamics solutions: a comprehensive analysis and an application to gait. , 2008, Gait & posture.

[29]  B. MacWilliams,et al.  A computationally efficient optimisation-based method for parameter identification of kinematically determinate and over-determinate biomechanical systems , 2010, Computer methods in biomechanics and biomedical engineering.

[30]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 3. Soft tissue artifact assessment and compensation. , 2005, Gait & posture.

[31]  P. Veltink,et al.  Evaluation of instrumented shoes for ambulatory assessment of ground reaction forces. , 2007, Gait & posture.

[32]  Ayman Habib,et al.  OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement , 2007, IEEE Transactions on Biomedical Engineering.

[33]  D. Howard,et al.  Whole body inverse dynamics over a complete gait cycle based only on measured kinematics. , 2008, Journal of biomechanics.

[34]  S J Dixon,et al.  Footscan pressure insoles: accuracy and reliability of force and pressure measurements in running. , 2010, Gait & posture.

[35]  Peter H. Veltink,et al.  Measuring orientation of human body segments using miniature gyroscopes and accelerometers , 2005, Medical and Biological Engineering and Computing.

[36]  Michael Damsgaard,et al.  Analysis of musculoskeletal systems in the AnyBody Modeling System , 2006, Simul. Model. Pract. Theory.

[37]  Matteo Giuberti,et al.  Inertial Sensing for Human Motion Analysis: Processing, Technologies, and Applications , 2014 .

[38]  Daniel Vélez Día,et al.  Biomechanics and Motor Control of Human Movement , 2013 .

[39]  N. C. Silver,et al.  Averaging Correlation Coefficients: Should Fishers z Transformation Be Used? , 1987 .

[40]  Tao Liu,et al.  A wearable force plate system for the continuous measurement of triaxial ground reaction force in biomechanical applications , 2010 .

[41]  Peter H. Veltink,et al.  Estimation of Full-Body Poses Using Only Five Inertial Sensors: An Eager or Lazy Learning Approach? , 2016, Sensors.

[42]  F. V. D. van der Helm,et al.  Geometry parameters for musculoskeletal modelling of the shoulder system. , 1992, Journal of biomechanics.

[43]  Michael Damsgaard,et al.  Prediction of ground reaction forces and moments during sports-related movements , 2016, Multibody System Dynamics.

[44]  Kunwoo Lee,et al.  Ground reaction force estimation using an insole-type pressure mat and joint kinematics during walking. , 2014, Journal of biomechanics.

[45]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 2: instrumental errors. , 2004, Gait & posture.

[46]  M. Damsgaard,et al.  Muscle recruitment by the min/max criterion -- a comparative numerical study. , 2001, Journal of biomechanics.

[47]  H F J M Koopman,et al.  Morphological muscle and joint parameters for musculoskeletal modelling of the lower extremity. , 2005, Clinical biomechanics.

[48]  Mark de Zee,et al.  Estimation of Ground Reaction Forces and Moments During Gait Using Only Inertial Motion Capture , 2016, Sensors.