Finite element analysis and stent design: Reduction of dogboning.

In Western countries, cardiovascular disease is the most common cause of death, often related to atherosclerosis. This paper offers a brief introduction into some aspects of this disease and its treatment, where the use of stents is gaining increasing importance. Stents are supporting - mostly metal - tubular mesh structures which are opened in an obstructed artery in order to reopen it, and to offer radial strength to prevent elastic recoil of the dilated vessel. In addition to a variety of experimental tests to study the behavior of (new) stent designs, advanced numerical models (e.g. Finite Element Models) may offer interesting insights in the mechanical behavior of stents and will undoubtedly influence the design of future generation stents. A brief literature review on numerical studies dealing with the mechanical behavior of stents is presented. Subsequently, the finite element method is exploited to investigate and compare different designs of a "first generation" Palmaz Schatz stent in order to reduce the dogboning (i.e. ends of stent open first during expansion) to a minimum. Our computational models (Abaqus ) are described in terms of geometry, constitutive material models, numerical aspects and output quantities. Altering the original symmetric stent design to asymmetric designs decreased the dogboning from 27.24% to less than 10% for the vast majority of the studied asymmetric designs. For one particular configuration, the dogboning effect vanished completely. For this reason, taking asymmetry into account in the design of stents seems very promising, at least from the perspective of dogboning. However, as the dogboning only takes into account the radii (R) at the central and distal part of the stent, nothing can be concluded concerning the uniformity of the complete stent expansion. The mean value (Rm) and the root mean square (R(RMS)) of radii (differences) of the stent at the end of the loading phase (P = 0.7 N/mm2) are much better parameters to give a clear indication of the uniformity of the expanded stent's shape. Although the model is suitable to study basic aspects of stent deployment, further research is necessary, especially accounting for newer generation stent geometries and more realistic balloon-stent interaction.

[1]  V. Fuster,et al.  Management of restenosis after coronary intervention. , 1996, American heart journal.

[2]  F. Etave,et al.  Mechanical properties of coronary stents determined by using finite element analysis. , 2001, Journal of biomechanics.

[3]  E. Sacco,et al.  Finite-element Analysis of a Stenotic Artery Revascularization Through a Stent Insertion , 2001 .

[4]  S. Al-Hassani,et al.  A method for investigating the mechanical properties of intracoronary stents using finite element numerical simulation. , 2001, International journal of cardiology.

[5]  F. Auricchio,et al.  Mechanical behavior of coronary stents investigated through the finite element method. , 2002, Journal of biomechanics.

[6]  S. Chua,et al.  Finite-element simulation of stent expansion , 2002 .

[7]  Lorenza Petrini,et al.  DEPLOYMENT OF AN INTRAVASCULAR STENT IN CORONARY STENOTIC ARTERIES: A COMPUTATIONAL STUDY , 2003 .

[8]  S. Chua,et al.  Finite element simulation of stent and balloon interaction , 2003 .

[9]  Lorenza Petrini,et al.  Numerical analysis of vascular stents exploiting shape memory alloy behavior. , 2003 .

[10]  Lorenza Petrini,et al.  Numerical investigation of the intravascular coronary stent flexibility. , 2004, Journal of biomechanics.

[11]  S. Chua,et al.  Finite element simulation of slotted tube (stent) with the presence of plaque and artery by balloon expansion , 2004 .

[12]  Gerhard A. Holzapfel,et al.  A Layer-Specific Three-Dimensional Model for the Simulation of Balloon Angioplasty using Magnetic Resonance Imaging and Mechanical Testing , 2002, Annals of Biomedical Engineering.

[13]  S. Chua,et al.  Effects of varying slotted tube (stent) geometry on its expansion behaviour using finite element method , 2004 .

[14]  Francesco Migliavacca,et al.  Does numerical simulation reflect really the mechanical behaviour of a stent , 2005 .

[15]  J Wouter Jukema,et al.  Drug-eluting stents: results, promises and problems. , 2005, International journal of cardiology.

[16]  Gerhard A Holzapfel,et al.  Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs. , 2005, Journal of biomechanical engineering.

[17]  De BeuleM.,et al.  Finite element analysis and stent design , 2006 .

[18]  Weiqiang Wang,et al.  Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method. , 2006, Journal of biomechanics.

[19]  R. Van Impe,et al.  A finite element model of a stainless steel stent expansion , 2006 .