Neurological and general outcome in low-risk coronary artery bypass patients using heparin coated circuits.

[1]  R. Anderson,et al.  The effect of cardiotomy suction on the brain injury marker S100beta after cardiopulmonary bypass. , 2000, The Annals of thoracic surgery.

[2]  E. Fosse,et al.  Heparin-coated cardiopulmonary bypass equipment. I. Biocompatibility markers and development of complications in a high-risk population. , 1999, The Journal of thoracic and cardiovascular surgery.

[3]  C. Baufreton,et al.  Inflammatory response to cardiopulmonary bypass using two different types of heparin-coated extracorporeal circuits , 1998, Perfusion.

[4]  C. Alling,et al.  Significance of serum S100 release after coronary artery bypass grafting. , 1998, The Annals of thoracic surgery.

[5]  R. Shemin,et al.  Effect of anticoagulation protocol on outcome in patients undergoing CABG with heparin-bonded cardiopulmonary bypass circuits. , 1998, The Annals of thoracic surgery.

[6]  C. Hack,et al.  Heparin coating of extracorporeal circuits inhibits contact activation during cardiac operations. , 1997, The Journal of thoracic and cardiovascular surgery.

[7]  T. Karlsson,et al.  Clinical effects of the heparin coated surface in cardiopulmonary bypass. , 1997, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[8]  S. Bannan,et al.  Low heparinization with heparin-bonded bypass circuits: is it a safe strategy? , 1997, The Annals of thoracic surgery.

[9]  A. Kuitunen,et al.  Cardiopulmonary bypass with heparin-coated circuits and reduced systemic anticoagulation. , 1997, The Annals of thoracic surgery.

[10]  G. Tangen,et al.  Heparinized cardiopulmonary bypass and full heparin dose marginally improve clinical performance. , 1996, The Annals of thoracic surgery.

[11]  R. Shemin,et al.  Heparin-bonded circuits with a reduced anticoagulation protocol in primary CABG: a prospective, randomized study. , 1996, The Annals of thoracic surgery.

[12]  E. Fosse,et al.  Disparity in blood activation by two different heparin-coated cardiopulmonary bypass systems. , 1995, The Annals of thoracic surgery.

[13]  P. Bezemer,et al.  Reduced complement activation and improved postoperative performance after cardiopulmonary bypass with heparin-coated circuits. , 1995, The Journal of thoracic and cardiovascular surgery.

[14]  G. Tangen,et al.  Completely heparinized cardiopulmonary bypass and reduced systemic heparin: clinical and hemostatic effects. , 1995, The Annals of thoracic surgery.

[15]  R. West,et al.  The association of memory complaint with computer-simulated everyday memory performance. , 1991, Journal of clinical and experimental neuropsychology.

[16]  E Tulving,et al.  Priming and human memory systems. , 1990, Science.

[17]  J. French,et al.  Long-term intellectual dysfunction following coronary artery bypass graft surgery: a six month follow-up study. , 1987, The Quarterly journal of medicine.

[18]  D. Schacter,et al.  Implicit and explicit memory for new associations in normal and amnesic subjects. , 1985, Journal of experimental psychology. Learning, memory, and cognition.

[19]  S Westaby,et al.  Complement and the damaging effects of cardiopulmonary bypass. , 1983, The Journal of thoracic and cardiovascular surgery.

[20]  K. Bergström,et al.  RELEASE OF ADENYLATE KINASE INTO CEREBROSPINAL FLUID DURING OPEN-HEART SURGERY AND ITS RELATION TO POSTOPERATIVE INTELLECTUAL FUNCTION , 1982, The Lancet.

[21]  J. G. Snodgrass,et al.  A standardized set of 260 pictures: norms for name agreement, image agreement, familiarity, and visual complexity. , 1980, Journal of experimental psychology. Human learning and memory.

[22]  J. Potter THE OPEN UNIVERSITY AND THE DISTRIBUTION OF DOCTORS , 1975, The Lancet.

[23]  T. Åberg,et al.  Routine registration of deviations from the norm in cardiac surgery: a potent clinical research tool and quality assurance measure. , 1997, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[24]  L. Menicanti,et al.  Beneficial effects of Duraflo II heparin-coated circuits on postperfusion lung dysfunction. , 1996, The Annals of thoracic surgery.

[25]  R. Colman,et al.  Surface-bound heparin fails to reduce thrombin formation during clinical cardiopulmonary bypass. , 1996, The Journal of thoracic and cardiovascular surgery.

[26]  H. Hansson,et al.  Decreased blood loss after cardiopulmonary bypass using heparin-coated circuit and 50% reduction of heparin dose. , 1992, Scandinavian journal of thoracic and cardiovascular surgery.