Application of ion trap technology to liquid chromatography/mass spectrometry quantitation of large peptides.

Triple quadrupole mass spectrometers are generally considered the instrument of choice for quantitative analysis. However, for the analysis of large peptides we have encountered some cases where, as the data presented here would indicate, ion trap mass spectrometers may be a good alternative. In general, specificity and sensitivity in bioanalytical liquid chromatography/mass spectrometry (LC/MS) assays are achieved via tandem MS (MS/MS) utilizing collision-induced dissociation (CID) while monitoring unique precursor to product ion transitions (i.e. selected reaction monitoring, SRM). Due to the difference in CID processes, triple quadrupoles and ion traps often generate significantly different fragmentation spectra of product ion species and intensities. The large peptidic analytes investigated here generated fewer fragments with higher relative abundance on the ion trap as compared to those generated on the triple quadrupole, resulting in lower limits of detection on the ion trap.

[1]  M. Walden,et al.  Analytical procedures for quantification of peptides in pharmaceutical research by liquid chromatography–mass spectrometry , 2004, Analytical and bioanalytical chemistry.

[2]  Fagen Zhang,et al.  Quantitation of human glutathione S-transferases in complex matrices by liquid chromatography/tandem mass spectrometry with signature peptides. , 2004, Rapid communications in mass spectrometry : RCM.

[3]  Fagen Zhang,et al.  Quantitative measurement of fathead minnow vitellogenin by liquid chromatography combined with tandem mass spectrometry using a signature peptide of vitellogenin , 2004, Environmental toxicology and chemistry.

[4]  Michael J MacCoss,et al.  Quantitative comparison of proteomic data quality between a 2D and 3D quadrupole ion trap. , 2006, Analytical chemistry.

[5]  James V Belcastro,et al.  An automated high throughput liquid chromatography-mass spectrometry process to assess the metabolic stability of drug candidates. , 2007, Assay and drug development technologies.

[6]  Kenneth K. Chan,et al.  Electrospray LC-MS/MS quantitation, stability, and preliminary pharmacokinetics of bradykinin antagonist polypeptide B201 (NSC 710295) in the mouse. , 2002, Journal of pharmaceutical and biomedical analysis.

[7]  S. Sagan,et al.  A direct approach to quantification of the cellular uptake of cell-penetrating peptides using MALDI-TOF mass spectrometry , 2006, Nature Protocols.

[8]  H. Szeto,et al.  Quantitative analysis of [Dmt1]DALDA in ovine plasma by capillary liquid chromatography-nanospray ion-trap mass spectrometry , 2004 .

[9]  M. Senko,et al.  A two-dimensional quadrupole ion trap mass spectrometer , 2002, Journal of the American Society for Mass Spectrometry.

[10]  R. March,et al.  Quadrupole storage mass spectrometry , 1989 .

[11]  Richard D. Smith,et al.  Ultra-sensitive, high throughput and quantitative proteomics measurements , 2005 .

[12]  J. Schellens,et al.  Absolute quantification of farnesylated Ras levels in complex samples using liquid chromatography fractionation combined with tryptic digestion and electrospray tandem mass spectrometry. , 2006, Analytical biochemistry.

[13]  Jeffrey R. Whiteaker,et al.  Antibody-based enrichment of peptides on magnetic beads for mass-spectrometry-based quantification of serum biomarkers. , 2007, Analytical biochemistry.

[14]  M. Bissell,et al.  A rapid test for the diagnosis of thrombotic thrombocytopenic purpura using surface enhanced laser desorption/ionization time‐of‐flight (SELDI‐TOF)‐mass spectrometry , 2006, Journal of thrombosis and haemostasis : JTH.

[15]  H. John Liquid chromatography–mass spectrometry in peptide drug discovery and development , 2005, Analytical and bioanalytical chemistry.

[16]  M. Senko,et al.  Automated strategies for obtaining standardized collisionally induced dissociation spectra on a benchtop ion trap mass spectrometer , 1999 .

[17]  William J Jusko,et al.  Utility of cleavable isotope-coded affinity-tagged reagents for quantification of low-copy proteins induced by methylprednisolone using liquid chromatography/tandem mass spectrometry. , 2006, Analytical chemistry.

[18]  R. Yost,et al.  Tandem-in-space and tandem-in-time mass spectrometry: triple quadrupoles and quadrupole ion traps , 1990 .

[19]  Shujia Dai,et al.  Quantification of sifuvirtide in monkey plasma by an on-line solid-phase extraction procedure combined with liquid chromatography/electrospray ionization tandem mass spectrometry. , 2005, Rapid communications in mass spectrometry : RCM.

[20]  D. J. Douglas,et al.  Improved Collisionally Activated Dissociation Efficiency and Mass Resolution on a Triple Quadrupole Mass Spectrometer System , 1995 .

[21]  J. Chapman Protein and peptide analysis by mass spectrometry , 1996 .

[22]  J. Schellens,et al.  Development and validation of a quantitative assay for the measurement of two HIV-fusion inhibitors, enfuvirtide and tifuvirtide, and one metabolite of enfuvirtide (M-20) in human plasma by liquid chromatography-tandem mass spectrometry. , 2006, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[23]  Knut Reinert,et al.  Absolute myoglobin quantitation in serum by combining two-dimensional liquid chromatography-electrospray ionization mass spectrometry and novel data analysis algorithms. , 2006, Journal of proteome research.

[24]  T. Shaler,et al.  Quantification of intermediate-abundance proteins in serum by multiple reaction monitoring mass spectrometry in a single-quadrupole ion trap. , 2006, Analytical chemistry.

[25]  M. Kanaoka,et al.  18O‐labeling quantitative proteomics using an ion trap mass spectrometer , 2005, Proteomics.

[26]  T. Veenstra,et al.  Quantitative analysis of the low molecular weight serum proteome using 18O stable isotope labeling in a lung tumor xenograft mouse model , 2005, Journal of the American Society for Mass Spectrometry.