Polyimide-etalon all-optical ultrasound transducer for high frequency applications

We have enhanced our design for an all-optical high frequency ultrasound transducer consisting of a UV-absorbing polyimide film integrated into an etalon receiver operating in the NIR range. A dielectric stack having high NIR reflectivity and high UV transmittance was chosen as the first mirror for increased sensitivity and the allowance of polyimide as the etalon medium. A 13 ns, 0.7 μJ optical pulse at 355 nm and a continuous-wave NIR laser were focused onto the structure with a spot diameter of 120 and 35 μm, respectively. In receive mode the etalon had a noise-equivalent pressure of 4.1 kPa over a bandwidth of 5 – 50 MHz (0.61 Pa/√Hz ). The device generated a pressure of 270 kPa at a depth of 200 μm, and the -3 dB bandwidth of the emission extended from 27 to 60 MHz. In transmit/receive mode, the pulse-echo had a center frequency of 35 MHz with a -6 dB bandwidth of 49 MHz (140 %). Lastly, wire targets were imaged by scanning the UV spot to create a synthetic aperture of transmitters centered upon a single receiver.

[1]  V. Schmitz,et al.  Reconstruction by the synthetic aperture focussing technique (SAFT) , 1986 .

[2]  Edward Z. Zhang,et al.  A miniature all-optical photoacoustic imaging probe , 2011, BiOS.

[3]  Tao Ling,et al.  High-sensitivity and wide-directivity ultrasound detection using high Q polymer microring resonators. , 2011, Applied physics letters.

[4]  A. Nikoozadeh,et al.  Volumetric real-time imaging using a CMUT ring array , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  Pai-Chi Li,et al.  All-optical scanhead for ultrasound and photoacoustic dual-modality imaging. , 2012, Optics express.

[6]  S. Krishnaswamy,et al.  Photoacoustic probes for nondestructive testing and biomedical applications. , 2002, Applied optics.

[7]  Tao Ling,et al.  Carbon nanotube composite optoacoustic transmitters for strong and high frequency ultrasound generation. , 2010, Applied physics letters.

[8]  M. O'Donnell,et al.  High frequency optoacoustic arrays using etalon detection , 2000, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  M. O’Donnell,et al.  Characterization of a broadband all-optical ultrasound transducer-from optical and acoustical properties to imaging , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  Robert Lee Melcher,et al.  20‐MHz acoustic waves from pulsed thermoelastic expansions of constrained surfaces , 1977 .

[11]  D.N. Stephens,et al.  Optimizing the beam pattern of a forward-viewing ring-annular ultrasound array for intravascular imaging , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  Broadband optical ultrasound sensor with a unique open-cavity structure. , 2011, Journal of biomedical optics.

[13]  F. Perennes,et al.  Transduction mechanisms of the Fabry-Perot polymer film sensing concept for wideband ultrasound detection , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  Matthew O'Donnell,et al.  Optoacoustic imaging using thin polymer étalon , 2005 .

[15]  Katerina K Naka,et al.  Clinical Indications for Intravascular Ultrasound Imaging , 2010, Echocardiography.

[16]  M. O'Donnell,et al.  A high-frequency, 2-D array element using thermoelastic expansion in PDMS , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  Sheng-Wen Huang,et al.  An integrated optoacoustic transducer combining etalon and black PDMS structures , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  G. S. Taylor,et al.  Laser-generated ultrasound: its properties, mechanisms and multifarious applications , 1993 .

[19]  E. Romagnoli,et al.  Is intravascular ultrasound beneficial for percutaneous coronary intervention of bifurcation lesions? Evidence from a 4,314-patient registry , 2011, Clinical Research in Cardiology.

[20]  P C Beard,et al.  Extrinsic optical-fiber ultrasound sensor using a thin polymer film as a low-finesse Fabry-Perot interferometer. , 1996, Applied optics.

[21]  P. Beard,et al.  A Fabry-Perot fiber-optic ultrasonic hydrophone for the simultaneous measurement of temperature and acoustic pressure. , 2009, The Journal of the Acoustical Society of America.

[22]  Y. Yoon,et al.  Thermoelastic response of thin metal films and their adjacent materials , 2013 .

[23]  P.C. Beard Two-dimensional ultrasound receive array using an angle-tuned Fabry-Perot polymer film sensor for transducer field characterization and transmission ultrasound imaging , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[24]  D. Menichelli,et al.  Efficient laser-ultrasound generation by using heavily absorbing films as targets , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  Matthew O'Donnell,et al.  Optical generation of high frequency ultrasound using two-dimensional gold nanostructure , 2006 .

[26]  J. Krzywiński,et al.  Spot size characterization of focused non-Gaussian X-ray laser beams. , 2010, Optics express.

[27]  Shriram Sethuraman,et al.  Spectroscopic intravascular photoacoustic imaging to differentiate atherosclerotic plaques. , 2008, Optics express.