Effects of Non-Elevation-Focalized Linear Array Transducer on Ultrasound Plane-Wave Imaging

Plane-wave ultrasound imaging (PWUS) has become an important method of ultrasound imaging in recent years as its frame rate has exceeded 10,000 frames per second, allowing ultrasound to be used for two-dimensional shear wave detection and functional brain imaging. However, compared to the traditional focusing and scanning method, PWUS images always suffer from a degradation of lateral resolution and contrast. To improve the image quality of PWUS, many different beamforming algorithms have been proposed and verified. Yet the influence of transducer structure is rarely studied. For this paper, the influence of using an acoustic lens for PWUS was evaluated. Two linear array transducers were fabricated. One was not self-focalized in the elevation direction (non-elevation-focalized transducer, NEFT); the other one was a traditional elevation-focalized transducer (EFT). An initial simulation was conducted to show the influence of elevation focusing. Then the images obtained with NEFT on a standard ultrasound imaging phantom were compared with those obtained with EFT. It was demonstrated that, in a relatively deep region, the contrast of an NEFT image is better than that of an EFT image. These results indicate that a more sophisticated design of ultrasound transducer would further improve the image quality of PWUS.

[1]  J. Lu,et al.  Experimental study of high frame rate imaging with limited diffraction beams. , 1998, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[2]  J. Arendt Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .

[3]  M. Fink,et al.  Shear modulus imaging with 2-D transient elastography , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  Georg Schmitz,et al.  Compressed Sensing for Fast Image Acquisition in Pulse-Echo Ultrasound , 2012 .

[5]  Bin Li,et al.  Adaptive Sparse Representation Beamformer for High-Frame-Rate Ultrasound Imaging Instrument , 2012, IEEE Transactions on Instrumentation and Measurement.

[6]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[7]  Jian-yu Lu,et al.  2D and 3D high frame rate imaging with limited diffraction beams , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  K. Shung,et al.  Diagnostic Ultrasound: Imaging and Blood Flow Measurements , 2005 .

[9]  M. Fink,et al.  Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  J A Jensen,et al.  In-vivo Examples of Flow Patterns With The Fast Vector Velocity Ultrasound Method , 2009, Ultraschall in der Medizin.

[11]  M. Fink,et al.  Ultrafast compound imaging for 2-D motion vector estimation: application to transient elastography , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  Juan Esteban Arango,et al.  3D ultrafast ultrasound imaging in vivo , 2014, Physics in medicine and biology.

[13]  J Bercoff,et al.  Ultrafast compound doppler imaging: providing full blood flow characterization , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  M. Fink,et al.  Functional ultrasound imaging of the brain , 2011, Nature Methods.

[15]  M. Fink,et al.  Supersonic shear imaging: a new technique for soft tissue elasticity mapping , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  M. Fink,et al.  Time-Resolved Pulsed Elastography with Ultrafast Ultrasonic Imaging , 1999, Ultrasonic imaging.