Nitrogen dioxide exposures inside ice skating rinks.

OBJECTIVES The common operation of fuel-powered resurfacing equipment in enclosed ice skating rinks has the potential for producing high concentrations of carbon monoxide and nitrogen dioxide. Exposures to these gaseous combustion products may adversely affect the health of those inside the rink. Little information is available on pollutant concentrations under normal operating conditions. METHODS One-week average nitrogen dioxide concentrations in 70 northeastern US rinks were measured with passive samplers during normal winter season conditions. RESULTS The median nitrogen dioxide level inside rinks was 180 ppb, more than 10 times higher than the median outdoor concentration. One-week average nitrogen dioxide concentrations above 1000 ppb were measured in 10% of the rinks. CONCLUSIONS Considering that short-term peak concentrations were likely to have reached two to five times the measured 1-week averages, our results suggest that nitrogen dioxide levels were well above short-term air quality guidelines and constitute a public health concern of considerable magnitude.

[1]  K Sexton,et al.  Formaldehyde concentrations inside private residences: a mail-out approach to indoor air monitoring. , 1986, Journal of the Air Pollution Control Association.

[2]  V. Mohsenin Effect of vitamin C on NO2-induced airway hyperresponsiveness in normal subjects. A randomized double-blind experiment. , 1987, The American review of respiratory disease.

[3]  D. E. Anderson,et al.  Problems created for ice arenas by engine exhaust. , 1971, American Industrial Hygiene Association journal.

[4]  Silo-filler's disease: a new perspective. , 1989, Mayo Clinic proceedings.

[5]  Yukio Yanagisawa,et al.  A badge-type personal sampler for measurement of personal exposure to NO2 and NO in ambient air , 1982 .

[6]  John D. Spengler,et al.  The Boston residential NO2 characterization study—II. Survey methodology and population concentration estimates , 1988 .

[7]  John D. Spengler,et al.  Carbon Monoxide and Nitrogen Dioxide Levels in an Indoor Ice Skating Rink with Mitigation Methods , 1993 .

[8]  P. Morrow,et al.  Toxicological data on NOx: an overview. , 1984, Journal of toxicology and environmental health.

[9]  É. Dewailly,et al.  Carbon monoxide in indoor ice skating rinks: evaluation of absorption by adult hockey players. , 1990, American journal of public health.

[10]  Sharon R. Paulsen State of Minnesota , 1990 .

[11]  J. Charpin,et al.  Effect of short-term, low-level nitrogen dioxide exposure on bronchial sensitivity of asthmatic patients. , 1976, The Journal of clinical investigation.

[12]  N. Rothman,et al.  Nitrogen dioxide-induced respiratory illness in ice hockey players. , 1990, JAMA.