Study of Wind Turbine based SEIG under Balanced/Unbalanced Loads and Excitation

This paper presents the performance of a stand-alone self-excited induction generator (SEIG) driven by fixed pitch wind turbine. The main objective of the paper is: (i) dynamic study of SEIG under balanced R-L/R-C loads (ii) dynamic study of SEIG under balanced and unbalanced excitation, (iii) Fixed pitch wind turbine model has been considered for driving induction generator. An approach based on dynamic equations of an isolated SEIG under balanced/unbalanced conditions of loads is employed to study the behaviour of the system. The SEIG model with balanced/un-balanced load and excitation has been simulated using MATLAB/SIMULINK. DOI: http://dx.doi.org/10.11591/ijece.v2i3.303

[1]  D. Seyoum,et al.  The dynamic characteristics of an isolated self-excited induction generator driven by a wind turbine , 2008, 2008 International Conference on Electrical Machines and Systems.

[2]  Emil Levi,et al.  An experimental investigation of self-excitation in capacitor excited induction generators , 2000 .

[3]  Paul C. Krause,et al.  Simulation of Symmetrical Induction Machinery , 1965 .

[4]  A. Kumar,et al.  Performance of wind driven induction generator under balanced/unbalanced load and excitation , 2011, 2011 IEEE Power and Energy Society General Meeting.

[5]  V. T. Ranganathan,et al.  A Method of Tracking the Peak Power Points for a Variable Speed Wind Energy Conversion System , 2002, IEEE Power Engineering Review.

[6]  L. Ouazenne,et al.  Analysis of the Isolated Induction Generator , 1983, IEEE Power Engineering Review.

[7]  J. L. Woodward,et al.  Excitation balancing of a self-excited induction generator for maximum power output , 1988 .

[8]  Bhim Singh,et al.  Transient performance of the self regulated short shunt self excited induction generator , 1995 .

[9]  Felix A. Farret,et al.  Alternative Energy Systems : Design and Analysis with Induction Generators, Second Edition , 2007 .

[10]  Cheng-Tsung Liu,et al.  Transient simulation technique for studies of self-excited generator systems , 1995 .

[11]  A. Kishore,et al.  Dynamic Analysis and Control of Output Voltage of a Wind Turbine Driven Isolated Induction Generator , 2006, 2006 IEEE International Conference on Industrial Technology.

[12]  A. H. Al-Bahrani,et al.  Steady state analysis and performance characteristics of a three-phase induction generator self excited with a single capacitor , 1990 .

[13]  Li Wang,et al.  Dynamic performances of an isolated self-excited induction generator under various loading conditions , 1999 .

[14]  O. P. Malik,et al.  Analysis of self-excited induction generators , 1982 .

[15]  G. J. Berg,et al.  Steady State Analysis of Capacitor Self-Excited Induction Generators , 1984 .

[16]  Sanjay Kumar Jain,et al.  Transient performance of three-phase self-excited induction generator during balanced and unbalanced faults , 2002 .

[17]  Mutsuo Nakaoka,et al.  Minimum excitation capacitance requirements for wind turbine coupled stand-alone self-excited induction generator with voltage regulation based on SVC , 2003, The 25th International Telecommunications Energy Conference, 2003. INTELEC '03..

[18]  R.C. Bansal,et al.  Three-phase self-excited induction generators: an overview , 2005, IEEE Transactions on Energy Conversion.

[19]  Ramesh C. Bansal,et al.  A novel mathematical modelling of induction generator for reactive power control of isolated hybrid power systems , 2004 .

[20]  B. Palle,et al.  Dynamic simulation and analysis of parallel self-excited induction generators for islanded wind farm systems , 2005, IEEE Transactions on Industry Applications.

[21]  Avinash Kishore,et al.  A Generalized State-Space Modeling of Three Phase Self-Excited Induction Generator For Dynamic Characteristics and Analysis , 2006, ICIEA 2006.

[22]  B. Palle,et al.  State space modeling of parallel self-excited induction generators for wind farm simulation , 2004, Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting..

[23]  Li Wang,et al.  A novel analysis on the performance of an isolated self-excited induction generator , 1997 .

[24]  O. P. Malik,et al.  Wind Energy Conversion Using A Self-Excited Induction Generator , 1983, IEEE Transactions on Power Apparatus and Systems.