Objective: Recording a compound action potential in response to electrical stimulation requires attention to minimize contamination due to electrical stimulus artifact. In patients implanted with the Nucleus® 24 device, the electrically evoked whole‐nerve potential (EAP) is recorded using a neural response telemetry (NRT) system. This system employs a forward‐masking technique that greatly reduces stimulus artifact. However, theoretical considerations and experimental animal data suggest that the technique may distort the acquired EAP waveform under some situations. We proposed and evaluated a modification to the forward‐masking technique that addresses this concern, particularly during collection of refractory recovery data. Design: We first examined neural responses of the electrically stimulated auditory nerve using cat preparations. Through single‐fiber recordings from cats, we demonstrated underlying physiological limitations likely encountered with the “standard” forward masking technique. We then recorded feline EAP waveforms using both the standard technique and our proposed, modified, technique. Finally, we collected EAP data from human cochlear implant patients using both artifact reduction methods. These comparisons allowed us to evaluate the effectiveness of our modification. Results: The cat EAP data demonstrated that the standard forward‐masking technique currently in use in the Nucleus® NRT system can distort the EAP waveform when the nerve is partially refractory. In the cat, this distortion resulted in forward‐masking recovery curves with artifactually prolonged recovery times and inaccurate latency trends. Similar effects were observed in the comparison of human recovery curves obtained using both the standard and modified techniques. In some cases, the modified technique produced EAP waveforms with more clearly defined peaks than were obtainable with the standard method. Conclusions: Consideration should be given to implementing our modified forward‐masking artifact reduction scheme, because it introduces less distortion of the EAP waveform and accordingly provides for more accurate assessment of the refractory properties of the electrically stimulated nerve.
[1]
P J Abbas,et al.
Electrically evoked whole nerve action potentials in Ineraid cochlear implant users: responses to different stimulating electrode configurations and comparison to psychophysical responses.
,
1996,
Journal of speech and hearing research.
[2]
Charles A. Miller,et al.
Electrically evoked compound action potentials of guinea pig and cat: responses to monopolar, monophasic stimulation
,
1998,
Hearing Research.
[3]
P J Abbas,et al.
Electrically evoked whole-nerve action potentials: parametric data from the cat.
,
1990,
The Journal of the Acoustical Society of America.
[4]
P. Stypulkowski,et al.
Physiological properties of the electrically stimulated auditory nerve. I. Compound action potential recordings
,
1984,
Hearing Research.
[5]
P. Stypulkowski,et al.
Temporal response patterns of single auditory nerve fibers elicited by periodic electrical stimuli
,
1987,
Hearing Research.
[6]
P J Abbas,et al.
Preliminary experience with neural response telemetry in the nucleus CI24M cochlear implant.
,
1998,
The American journal of otology.
[7]
Rainer Hartmann,et al.
Discharge patterns of cat primary auditory fibers with electrical stimulation of the cochlea
,
1984,
Hearing Research.
[8]
F. B. Simmons,et al.
Estimating Eighth Nerve Survival by Electrical Stimulation
,
1983,
The Annals of otology, rhinology, and laryngology.
[9]
Charles A. Miller,et al.
The use of long-duration current pulses to assess nerve survival
,
1994,
Hearing Research.
[10]
P J Abbas,et al.
Electrically evoked whole-nerve action potentials: data from human cochlear implant users.
,
1990,
The Journal of the Acoustical Society of America.
[11]
J K Shallop,et al.
Summary of results using the nucleus CI24M implant to record the electrically evoked compound action potential.
,
1999,
Ear and hearing.