PEFC stacks as power sources for hybrid propulsion systems

Abstract In this paper the performance of two polymeric electrolyte fuel cell systems (FCS) for hybrid power trains are presented and discussed. In particular, an experimental analysis was effected on 2.4 and 20 kW stacks with the aim to investigate the energy management issues of the two FCSs for utilization as power sources in electric power trains for scooter and minibus, respectively. The stack characterizations permitted the effect of the main operative variables (temperature, pressure and stoichiometric ratio) on mean power density of cells to be evaluated. The FCS efficiency was evaluated and compared for the two traction systems, individuating the optimal operative conditions for automotive application and specifying the energy losses of the auxiliary components. The efficiency of both fuel cell systems resulted higher than 40% in a wide range of loads (100–600 mA/cm 2 ), with maximum values close to 50%. The experimental characterization of the two power trains was carried out on dynamic test benches, able to simulate the behaviour of the two vehicles on the European R40 driving cycle. The characterization of the two propulsion systems on R40 driving cycle evidenced that the overall efficiency was not affected significantly by the hybrid configuration adopted, as the efficiency values ranged from 27 to 29% in the different procedures analyzed.

[1]  Fortunato Migliardini,et al.  Performance investigation of 2.4 kW PEM fuel cell stack in vehicles , 2007 .

[2]  Ulrich Eberle,et al.  Fuel cell vehicles: Status 2007 , 2007 .

[3]  Minggao Ouyang,et al.  Analysis of the water and thermal management in proton exchange membrane fuel cell systems , 2006 .

[4]  F. Philipps,et al.  Dynamic investigation of PEFC stacks in interaction with the air supply system , 2006 .

[5]  José Roberto Camacho,et al.  The dynamic and steady state behavior of a PEM fuel cell as an electric energy source , 2006 .

[6]  James Larminie,et al.  Fuel Cell Systems Explained , 2000 .

[7]  Atilla Biyikoglu,et al.  Review of proton exchange membrane fuel cell models , 2005 .

[8]  N. Lymberopoulos,et al.  Techno-economic analysis of the integration of hydrogen energy technologies in renewable energy-based stand-alone power systems , 2007 .

[9]  Mohammad S. Alam,et al.  Dynamic modeling, design and simulation of a PEM fuel cell/ultra-capacitor hybrid system for vehicular applications , 2007 .

[10]  Ibrahim Dincer,et al.  Environmental and economic aspects of hydrogen production and utilization in fuel cell vehicles , 2006 .

[11]  James Mason,et al.  World energy analysis : H2 now or later? , 2007 .

[12]  U. Wagner,et al.  Experimental analysis of water management in a self-humidifying polymer electrolyte fuel cell stack , 2004 .

[13]  B. Yi,et al.  AC impedance characteristics of a 2 kW PEM fuel cell stack under different operating conditions and load changes , 2007 .

[14]  B. Smitha,et al.  Solid polymer electrolyte membranes for fuel cell applications¿a review , 2005 .

[15]  Xin-Jian Zhu,et al.  A 10kW class PEM fuel cell stack based on the catalyst-coated membrane (CCM) method , 2006 .

[16]  Minggao Ouyang,et al.  Modeling and optimization of the air system in polymer exchange membrane fuel cell systems , 2006 .

[17]  Fortunato Migliardini,et al.  An experimental study of a PEM fuel cell power train for urban bus application , 2008 .

[18]  Fortunato Migliardini,et al.  Experimental analysis and management issues of a hydrogen fuel cell system for stationary and mobile application , 2007 .

[19]  Fortunato Migliardini,et al.  Experimental assessment of energy-management strategies in fuel-cell propulsion systems , 2006 .

[20]  I. Dincer,et al.  Life cycle assessment of hydrogen fuel cell and gasoline vehicles , 2006 .

[21]  Fortunato Migliardini,et al.  Experimental study of a fuel cell power train for road transport application , 2005 .

[22]  Stefan Pischinger,et al.  Analysis of dynamic requirements for fuel cell systems for vehicle applications , 2006 .