Islanding detection using synchronized measurement in smart microgrids

This paper presents the issues involved in the detection of islanding via traditional methods as well as the implementation of 3-phase synchronized measurements. A proposed technique for better islanding recognition in microgrids using multiple PMUs was developed. A new method which uses 3 phase synchronized measurements was introduced for the detection of unbalanced or partial islanding of microgrids. This occurs when the microgrid loose only one phase of its link to the main grid. In addition to simulation of the proposed method in MATLAB/Simulink, experimental results are also obtained. A small scaled 3-phase power system at the laboratory scale was developed and used to compare the traditional and new techniques. The comparisons of experimental and simulation results show that the proposed technique was successfully verified.

[1]  M. Liserre,et al.  Overview of Anti-Islanding Algorithms for PV Systems. Part I: Passive Methods , 2006, 2006 12th International Power Electronics and Motion Control Conference.

[2]  P. Jarventausta,et al.  Problems related to Islanding Protection of Distributed Generation in Distribution Network , 2007, 2007 IEEE Lausanne Power Tech.

[3]  Tao Xia,et al.  Power system islanding detection based on wide area measurement systems , 2011, 2011 16th International Conference on Intelligent System Applications to Power Systems.

[4]  Liuchen Chang,et al.  Recent developments in islanding detection for distributed power generation , 2004, 2004 Large Engineering Systems Conference on Power Engineering (IEEE Cat. No.04EX819).

[5]  Toshihisa Funabashi,et al.  A review of islanding detection methods for distributed resources , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.

[6]  Zhihong Ye,et al.  Evaluation of anti-islanding schemes based on nondetection zone concept , 2003, IEEE 34th Annual Conference on Power Electronics Specialist, 2003. PESC '03..

[7]  Wilsun Xu,et al.  Comparative analysis between ROCOF and vector surge relays for distributed generation applications , 2005, IEEE Transactions on Power Delivery.

[8]  Inmaculada Zamora,et al.  Analysis of Remote Islanding Detection Methods for Distributed Resources , 2011 .

[9]  Mike Ropp,et al.  Using power line carrier communications to prevent islanding [of PV power systems] , 2000, Conference Record of the Twenty-Eighth IEEE Photovoltaic Specialists Conference - 2000 (Cat. No.00CH37036).

[10]  Alexandre Oudalov,et al.  Islanding detection in smart grids , 2010, 2010 IEEE Energy Conversion Congress and Exposition.

[11]  O. Samuelsson,et al.  Islanding detection and connection requirements , 2007, 2007 IEEE Power Engineering Society General Meeting.

[12]  Osama A. Mohammed,et al.  Laboratory-Based Smart Power System, Part I: Design and System Development , 2012, IEEE Transactions on Smart Grid.

[13]  D. John Morrow,et al.  Anti-islanding detection using Synchrophasors and Internet Protocol telecommunications , 2011, 2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies.

[14]  Fu Wang Review of islanding detection methods for distributed generation , 2011 .

[15]  D.J. Morrow,et al.  Internet based loss-of-mains detection for distributed generation , 2007, 2007 42nd International Universities Power Engineering Conference.

[16]  Osama A. Mohammed Design and Implementation of Laboratory-Based Smart Power System , 2011 .

[17]  Miles A Redfern,et al.  Protection against loss of utility grid supply for a dispersed storage and generation unit , 1993 .