Thermal Characterization of Prototypical Integral Collector Storage Systems With Immersed Heat Exchangers

Natural convection is measured in an enclosure that represents an integral collector storage system (ICS) with an immersed tube-bundle heat exchanger Heat transfer coefficients for bundles of 240 tubes contained in a thin enclosure of aspect ratio of 9.3:1 and inclined at 30 deg to the horizontal are obtained for a range of transient operating modes and pitch-to-diameter ratios of 1.5, 2.4, and 3.3. Results for isothermal and stratified enclosures yield a correlation for the overall Nusselt number NU D =(2.45 ±0.03)Ra 0.188 D , 230≤Ra D ≤9800. The characteristic temperature difference in the Rayleigh number is that between the average water temperature within the bundle and the tube wall temperature. Nusselt numbers are three times larger than those for a similarly configured single-tube and an eight-tube bundle. This increase is attributed to stronger fluid motion within the bundle and higher overall large scale circulation rates in the enclosure.

[1]  T. Dalton,et al.  Natural Convection Heat Transfer in Horizontal Rod-Bundle Enclosures , 1996 .

[2]  K. Kishinami,et al.  An Experimental Study of Free Convection Heat Transfer From a Horizontal Cylinder in a Vertical Array Set in Free Space Between Parallel Walls , 1983 .

[3]  Jane H. Davidson,et al.  Natural Convection from a Horizontal Tube Heat Exchanger Immersed in a Tilted Enclosure , 2002 .

[4]  Stuart W. Churchill,et al.  Correlating equations for laminar and turbulent free convection from a horizontal cylinder , 1975 .

[5]  Adrian Bejan,et al.  The optimal spacing between horizontal cylinders in a fixed volume cooled by natural convection , 1995 .

[6]  William A. Beckman,et al.  Transient Natural Convection in Enclosures With Application to Solar Thermal Storage Tanks , 1992 .

[7]  B. Gebhart,et al.  Interactions in natural convection from an array of heated elements, experimental , 1969 .

[8]  D. Edwards,et al.  Experimental Investigation of Natural Convection in Inclined Rectangular Regions of Differing Aspect Ratios , 1976 .

[9]  C. E. Bingham,et al.  Testing and analysis of immersed heat exchangers , 1986 .

[10]  Noam Lior,et al.  Long rolls generated by natural convection in an inclined, rectangular enclosure , 1983 .

[11]  R. O. Warrington,et al.  Natural Convection Heat Transfer Between Cylindrical Tube Bundles and a Cubical Enclosure , 1981 .

[12]  M. Asheghi,et al.  Free convection heat transfer from arrays of vertically separated horizontal cylinders at low Rayleigh numbers , 1994 .

[13]  R. Canaan,et al.  A numerical investigation of natural convection heat transfer within horizontal spent-fuel assemblies , 1996 .

[14]  Jane H. Davidson,et al.  Natural Convection From a Tube Bundle in a Thin Inclined Enclosure , 2004 .

[15]  Ephraim M Sparrow,et al.  Effect of Vertical Separation Distance and Cylinder-to-Cylinder Temperature Imbalance on Natural Convection for a Pair of Horizontal Cylinders , 1981 .

[16]  G. F. Marsters,et al.  Arrays of heated horizontal cylinders in natural convection , 1972 .

[17]  V. Morgan The Overall Convective Heat Transfer from Smooth Circular Cylinders , 1975 .

[18]  E. Sparrow,et al.  Effect of transverse misalignment on natural convection from a pair of parallel, vertically stacked, horizontal cylinders , 1983 .

[19]  Bahgat Sammakia,et al.  UNSTEADY NATURAL CONVECTION GENERATED BY A HEATED SURFACE WITHIN AN ENCLOSURE , 1986 .

[20]  Majid Keyhani,et al.  A numerical study of convection heat transfer within enclosed horizontal rod bundles , 1995 .