Simulations of a Scintillator Compton Gamma Imager for Safety and Security

We are designing an all-scintillator Compton gamma imager for use in security investigations and remediation actions involving radioactive threat material. To satisfy requirements for a rugged and portable instrument, we have chosen solid scintillator for the active volumes of both the scatter and absorber detectors. Using the BEAMnrc/EGSnrc Monte Carlo simulation package, we have constructed models using four different materials for the scatter detector: LaBr3 , NaI, CaF2 , and PVT. We have compared the detector performances using angular resolution, efficiency, and image resolution. We find that while PVT provides worse performance than that of the detectors based entirely on inorganic scintillators, all of the materials investigated for the scatter detector have the potential to provide performance adequate for our purposes.

[1]  K. Vetter,et al.  High-sensitivity Compton imaging with position-sensitive Si and Ge detectors , 2006 .

[2]  B. Phlips,et al.  A γ-ray background model for Monte Carlo simulations , 2007 .

[3]  S. Kurosawa,et al.  Gamma-ray imaging with a large micro-TPC and a scintillation camera , 2007 .

[4]  B. Smith,et al.  An Electronically-collimated Gamma-ray Detector for Localization of Radiation Sources , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[5]  Matts Roos,et al.  MINUIT-a system for function minimization and analysis of the parameter errors and correlations , 1984 .

[6]  Daming Zhu,et al.  Numerical simulation of simple position-sensitive γ-ray detector based on plastic scintillating fiber array (OFT-06-102R1) , 2008 .

[7]  Elena I. Novikova,et al.  Comparison of shielded uranium passive gamma-ray detection methods , 2006, SPIE Defense + Commercial Sensing.

[8]  Mark L. McConnell,et al.  A compton telescope for remote location and identification of radioactive material , 2009, 2009 IEEE Conference on Technologies for Homeland Security.

[9]  James D. Kurfess,et al.  Compton imager for detection of special nuclear material , 2007 .

[10]  Roland Ribberfors,et al.  Relationship of the relativistic Compton cross section to the momentum distribution of bound electron states , 1975 .

[11]  William W. Craig,et al.  SPEIR: A Ge Compton camera , 2004 .

[12]  D. Wehe,et al.  Hybrid gamma ray imaging—Model and results , 2007 .

[13]  M. Moszynski,et al.  Intrinsic energy resolution of NaI(Tl) , 2002 .

[14]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[15]  C. Ma,et al.  BEAM: a Monte Carlo code to simulate radiotherapy treatment units. , 1995, Medical physics.

[16]  J. Sullivan,et al.  Gamma-ray imaging with a Si/CsI(Tl) Compton detector. , 2006, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.