The aim of this project was to analyze the thermal performance of passive low-cost housing in half-humid tropical climate. The houses are located in Cuiaba-MT (15.5° southern latitude), one of the hottest cities in Brazil. The data about the typology of the houses were obtained from three representative construction systems; wood, masonry, and prefabricated. The measurements had been carried out through a year, during 20 consecutive days of each season and were evaluated by three distinct methodologies: (1) analyses of previous recommendations of the construction where the envelope materials were compared with the Brazilian standard NBR 15220-3/ 2005, (2) frequency, through dry bulb temperature with values of 18 °C and 29 °C, and (3) performance, by analysis of comfort levels and bioclimatic strategies processed by Analysis Bio 2.1.2 program in accordance to the adapted Bioclimatic Chart of Givoni for developing countries.