Brain shift during bur hole-based procedures using interventional MRI.

UNLABELLED OBJECT.: Brain shift during minimally invasive, bur hole-based procedures such as deep brain stimulation (DBS) electrode implantation and stereotactic brain biopsy is not well characterized or understood. We examine shift in various regions of the brain during a novel paradigm of DBS electrode implantation using interventional imaging throughout the procedure with high-field interventional MRI. METHODS Serial MR images were obtained and analyzed using a 1.5-T magnet prior to, during, and after the placement of DBS electrodes via frontal bur holes in 44 procedures. Three-dimensional coordinates in MR space of unique superficial and deep brain structures were recorded, and the magnitude, direction, and rate of shift were calculated. Measurements were recorded to the nearest 0.1 mm. RESULTS Shift ranged from 0.0 to 10.1 mm throughout all structures in the brain. The greatest shift was seen in the frontal lobe, followed by the temporal and occipital lobes. Shift was also observed in deep structures such as the anterior and posterior commissures and basal ganglia; shift in the pallidum and subthalamic region ipsilateral to the bur hole averaged 0.6 mm, with 9% of patients having over 2 mm of shift in deep brain structures. Small amounts of shift were observed during all procedures; however, the initial degree of shift and its direction were unpredictable. CONCLUSIONS Brain shift is continual and unpredictable and can render traditional stereotactic targeting based on preoperative imaging inaccurate even in deep brain structures such as those used for DBS.

[1]  S. Gill,et al.  MAGNETIC RESONANCE IMAGING‐DIRECTED METHOD FOR FUNCTIONAL NEUROSURGERY USING IMPLANTABLE GUIDE TUBES , 2007, Neurosurgery.

[2]  Thomas Foltynie,et al.  Minimizing Brain Shift in Stereotactic Functional Neurosurgery , 2010, Neurosurgery.

[3]  G. Westby,et al.  Targeting the subthalamic nucleus for deep brain stimulation: technical approach and fusion of pre- and postoperative MR images to define accuracy of lead placement , 2005, Journal of Neurology, Neurosurgery & Psychiatry.

[4]  N. Hata,et al.  Serial Intraoperative Magnetic Resonance Imaging of Brain Shift , 2001, Neurosurgery.

[5]  Hideki Oshima,et al.  Direction and Predictive Factors for the Shift of Brain Structure During Deep Brain Stimulation Electrode Implantation for Advanced Parkinson's Disease , 2008, Neuromodulation : journal of the International Neuromodulation Society.

[6]  R. Maciunas,et al.  The application accuracy of stereotactic frames. , 1994, Neurosurgery.

[7]  Derek L. G. Hill,et al.  Measurement of Intraoperative Brain Surface Deformation Under a Craniotomy , 1998, MICCAI.

[8]  Patricia Limousin,et al.  Avoiding the ventricle: a simple step to improve accuracy of anatomical targeting during deep brain stimulation. , 2009, Journal of neurosurgery.

[9]  R. Frysinger,et al.  Cortical and subcortical brain shift during stereotactic procedures. , 2007, Journal of neurosurgery.

[10]  A. Jödicke,et al.  Intraoperative three-dimensional ultrasonography: an approach to register brain shift using multidimensional image processing. , 1998, Minimally invasive neurosurgery : MIN.

[11]  Charles A Sansur,et al.  Sulcal and ventricular trajectories in stereotactic surgery. , 2009, Journal of neurosurgery.

[12]  Aviva Abosch,et al.  Thalamic Deep Brain Stimulation for Essential Tremor: Relation of Lead Location to Outcome , 2004, Neurosurgery.

[13]  Thomas Foltynie,et al.  Improving Targeting in Image-Guided Frame-Based Deep Brain Stimulation , 2010, Neurosurgery.

[14]  Paul S Larson,et al.  Implantation of deep brain stimulator electrodes using interventional MRI. , 2009, Neurosurgery clinics of North America.

[15]  V A Coenen,et al.  Minimizing Brain Shift during Functional Neurosurgical Procedures – A Simple Burr Hole Technique that can Decrease CSF Loss and Intracranial Air , 2011, Central European neurosurgery.

[16]  C. Nimsky,et al.  Quantification of, Visualization of, and Compensation for Brain Shift Using Intraoperative Magnetic Resonance Imaging , 2000, Neurosurgery.

[17]  P F Hemler,et al.  Method for correcting magnetic resonance image distortion for frame-based stereotactic surgery, with preliminary results. , 1995, Journal of image guided surgery.

[18]  P. Kelly,et al.  Computer-assisted stereotaxic laser resection of intra-axial brain neoplasms. , 1986, Journal of neurosurgery.

[19]  Haiying Liu,et al.  Investigation of intraoperative brain deformation using a 1.5-T interventional MR system: preliminary results , 1998, IEEE Transactions on Medical Imaging.

[20]  K. Paulsen,et al.  Intraoperatively updated neuroimaging using brain modeling and sparse data. , 1999, Neurosurgery.

[21]  K. Paulsen,et al.  A computational model for tracking subsurface tissue deformation during stereotactic neurosurgery , 1999, IEEE Transactions on Biomedical Engineering.

[22]  Keith D. Paulsen,et al.  Updated Neuroimaging Using Intraoperative Brain Modeling and Sparse Data , 2000, Stereotactic and Functional Neurosurgery.

[23]  J. Patrick Intraoperative Brain Shift and Deformation: A Quantitative Analysis of Cortical Displacement in 28 Cases , 1998 .

[24]  Haiying Liu,et al.  Measurement and analysis of brain deformation during neurosurgery , 2003, IEEE Transactions on Medical Imaging.

[25]  S. Gill,et al.  MRI directed bilateral stimulation of the subthalamic nucleus in patients with Parkinson’s disease , 2003, Journal of neurology, neurosurgery, and psychiatry.

[26]  Philip A. Starr,et al.  Surgical Repositioning of Misplaced Subthalamic Electrodes in Parkinson’s Disease: Location of Effective and Ineffective Leads , 2009, Stereotactic and Functional Neurosurgery.

[27]  H Dickhaus,et al.  [Quantification of brain shift effects in MRI images]. , 1997, Biomedizinische Technik. Biomedical engineering.

[28]  James S. Duncan,et al.  Model-driven brain shift compensation , 2002, Medical Image Anal..

[29]  Seth Love,et al.  MRI-Directed Subthalamic Nucleus Surgery for Parkinson’s Disease , 2003, Stereotactic and Functional Neurosurgery.

[30]  Julien Modolo,et al.  Statistical determination of the optimal subthalamic nucleus stimulation site in patients with Parkinson disease. , 2007, Journal of neurosurgery.

[31]  Hartmut Dickhaus,et al.  Quantifizierung von Brain-Shift-Effekten in MR-Aufnahmen , 1997 .

[32]  N. Hata,et al.  Three-Dimensional Optical Flow Method for Measurement of Volumetric Brain Deformation from Intraoperative MR Images , 2000, Journal of computer assisted tomography.

[33]  Robert E. Gross,et al.  Assessment of Brain Shift Related to Deep Brain Stimulation Surgery , 2007, Stereotactic and Functional Neurosurgery.

[34]  Yasushi Miyagi,et al.  Brain shift: an error factor during implantation of deep brain stimulation electrodes. , 2007, Journal of neurosurgery.

[35]  P. Kelly,et al.  Location of the active contact within the subthalamic nucleus (STN) in the treatment of idiopathic Parkinson's disease. , 2004, Surgical neurology.