Comfort Exceedance Metrics in Mixed-Mode Buildings

This paper presents an analysis of comfort exceedan ce based on thermal simulations of a mixed-mode building, across a range of climate conditions. Mixed-mode buildings are, by definition, hybrids along a spectrum from sealed HV AC to 100% naturally ventilated, and little is known about how building design and operation details shape their occupants’ comfort expectations. Using simulations of a mixed-mode building with radiant cooling, results indicate that there is a large difference between predicted annual exceedance values calculated using PPD and the adaptive comfort model. Calculated exceedance values are also sensitive to model assumptions about shell performance, solar heat gai n, thermal mass, and control precision. It follows that future work should be undertaken to be tter characterize measured comfort in mixedmode buildings in the service of improved building design and operation, more accurate comfort modeling, and the development of related codes and standards.

[1]  E. Shove,et al.  Comfort in a lower carbon society , 2008 .

[2]  Leslie K. Norford,et al.  Naturally ventilated and mixed-mode buildings—Part I: Thermal modeling , 2009 .

[3]  Gregor P. Henze,et al.  Primary energy and comfort performance of ventilation assisted thermo-active building systems in continental climates , 2008 .

[4]  P. O. Fanger,et al.  Thermal comfort: analysis and applications in environmental engineering, , 1972 .

[5]  Richard Karl Strand,et al.  Modeling Radiant Systems in an Integrated Heat Balance Based Energy Simulation Program , 2002 .

[6]  F. Nicol,et al.  Derivation of the adaptive equations for thermal comfort in free-running buildings in European standard EN15251 , 2010 .

[7]  Derek Clements-Croome,et al.  Natural ventilation in non-domestic buildings , 2005 .

[8]  Leslie K. Norford,et al.  Naturally ventilated and mixed-mode buildings—Part II: Optimal control , 2009 .

[9]  Bjarne W. Olesen,et al.  Criteria for the indoor environment for energy performance of buildings , 2006 .

[10]  J. F. Nicol,et al.  Understanding the adaptive approach to thermal comfort , 1998 .

[11]  Gail Brager,et al.  Thermal comfort in naturally ventilated buildings: revisions to ASHRAE Standard 55 , 2002 .

[12]  Gail Brager,et al.  Occupant satisfaction in mixed-mode buildings , 2009 .

[13]  Mithra Moezzi Are comfort expectations of building occupants too high? , 2009 .

[14]  Sebastian Herkel,et al.  Comparison of low-energy office buildings in summer using different thermal comfort criteria , 2007 .

[15]  Bjarne W. Olesen,et al.  The philosophy behind EN15251: Indoor environmental criteria for design and calculation of energy performance of buildings , 2007 .