Artificial Placenta - Lung Assist Devices for Term and Preterm Newborns with Respiratory Failure

Respiratory insufficiency is a major cause of neonatal mortality and long-term morbidity, especially in very low birth weight infants. Today, non-invasive and mechanical ventilation are commonly accepted procedures to provide respiratory support to newborns, but they can reach their limit of efficacy. To overcome this technological plateau and further reduce mortality rates, the technology of an “artificial placenta”, which is a pumpless lung assist device connected to the umbilical vessels, would serve to expand the therapeutic spectrum when mechanical ventilation becomes inadequate to treat neonates with severe respiratory insufficiency. The first attempts to create such an artificial placenta took place more than 60 years ago. However, there has been a recent renaissance of this concept, including developments of its major components like the oxygenator, vascular access via umbilical vessels, flow control, as well as methods to achieve hemocompatibility in extracorporeal circuits. This paper gives a review of past and current development, animal experiments and human case studies of artificial placenta technology.

[1]  P. Selvaganapathy,et al.  Integrated microfluidic oxygenator bundles for blood gas exchange in premature infants , 2012, 2012 IEEE 25th International Conference on Micro Electro Mechanical Systems (MEMS).

[2]  Reint K Jellema,et al.  NeonatOx: a pumpless extracorporeal lung support for premature neonates. , 2011, Artificial organs.

[3]  D. Stolz,et al.  A biohybrid artificial lung prototype with active mixing of endothelialized microporous hollow fibers , 2010, Biotechnology and bioengineering.

[4]  S. Demirakça,et al.  A 20-year experience on neonatal extracorporeal membrane oxygenation in a referral center , 2010, Intensive Care Medicine.

[5]  N. Ambalavanan,et al.  Evaluation of a Pumpless Lung Assist Device in Hypoxia-Induced Pulmonary Hypertension in Juvenile Piglets , 2009, Pediatric Research.

[6]  H. Holtby,et al.  Emergency interventional lung assist for pulmonary hypertension. , 2009, Anesthesia and analgesia.

[7]  Raymond H. W. Lam,et al.  Culturing Aerobic and Anaerobic Bacteria and Mammalian Cells with a Microfluidic Differential Oxygenator , 2009, Analytical chemistry.

[8]  Simon Nadel,et al.  Clinical practice parameters for hemodynamic support of pediatric and neonatal septic shock: 2007 update from the American College of Critical Care Medicine* , 2009, Critical care medicine.

[9]  T. Okai,et al.  Artificial placenta: long-term extrauterine incubation of isolated goat fetuses. , 2008, Artificial organs.

[10]  M. Torloni,et al.  The cross‐sectional area of umbilical cord components in normal pregnancy , 2007, International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics.

[11]  Gerhard Ziemer,et al.  Effect of biopassive and bioactive surface-coatings on the hemocompatibility of membrane oxygenators. , 2007, Journal of biomedical materials research. Part B, Applied biomaterials.

[12]  J. Zwischenberger,et al.  Seventy-two hour gas exchange performance and hemodynamic properties of NOVALUNG®iLA as a gas exchanger for arteriovenous carbon dioxide removal , 2005, Perfusion.

[13]  T. Kusaka,et al.  Estimation of circulating blood volume in infants using the pulse dye densitometry method , 2005, Paediatric anaesthesia.

[14]  Laurance Lequier,et al.  Extracorporeal Life Support in Pediatric and Neonatal Critical Care: A Review , 2004, Journal of intensive care medicine.

[15]  Yukihiko Nosé,et al.  Development of the oxygenator: past, present, and future , 2004, Journal of Artificial Organs.

[16]  H. Wendel,et al.  Hemocompatibility of PMEA Coated Oxygenators Used for Extracorporeal Circulation Procedures , 2004, ASAIO journal.

[17]  J. Palmer Fluid therapy in the neonate: not your mother's fluid space. , 2004, The Veterinary clinics of North America. Equine practice.

[18]  D. Dragomer,et al.  The Capiox RX05 oxygenator: pediatric clinical observations , 2003, Perfusion.

[19]  O. Linderkamp,et al.  Longitudinal evaluation of energy expenditure in preterm infants with birth weight less than 1000 g , 2003, British Journal of Nutrition.

[20]  T. Kiserud,et al.  Degree of fetal umbilical venous constriction at the abdominal wall in a low‐risk population at 20–40 weeks of gestation , 2002, Prenatal diagnosis.

[21]  C. Jang,et al.  Extrauterine incubation of fetal goats applying the extracorporeal membrane oxygenation via umbilical artery and vein. , 2002, Journal of Korean medical science.

[22]  L. Hsu Heparin-coated cardiopulmonary bypass circuits: current status , 2001, Perfusion.

[23]  M K Pugsley,et al.  Methods of blood flow measurement in the arterial circulatory system. , 2000, Journal of pharmacological and toxicological methods.

[24]  J. Goldkrand,et al.  Volumetric flow in the umbilical artery: normative data. , 2000, The Journal of maternal-fetal medicine.

[25]  J. Hayashi,et al.  Biocompatibility of a silicone-coated polypropylene hollow fiber oxygenator in an in vitro model. , 1999, The Annals of thoracic surgery.

[26]  H. Matsuda,et al.  Nitric oxide gas infusion to the oxygenator enhances the biocompatibility of heparin coated extracorporeal bypass circuits. , 1998, ASAIO journal.

[27]  M. Sakata,et al.  A new artificial placenta with a centrifugal pump: long-term total extrauterine support of goat fetuses. , 1998, The Journal of thoracic and cardiovascular surgery.

[28]  M. Sakata,et al.  Arterio-venous extracorporeal membrane oxygenation of fetal goat incubated in artificial amniotic fluid (artificial placenta): influence on lung growth and maturation. , 1998, Journal of pediatric surgery.

[29]  J A Wegner,et al.  Oxygenator anatomy and function. , 1997, Journal of cardiothoracic and vascular anesthesia.

[30]  G. Cutter,et al.  The association of heparin exposure with intraventricular hemorrhage among very low birth weight infants. , 1995, Journal of perinatology : official journal of the California Perinatal Association.

[31]  T. Okai,et al.  Development of an artificial placenta: survival of isolated goat fetuses for three weeks with umbilical arteriovenous extracorporeal membrane oxygenation. , 1993, Artificial organs.

[32]  J. Gaylor,et al.  Membrane oxygenators: current developments in design and application. , 1988, Journal of biomedical engineering.

[33]  W. van Oeveren,et al.  Bubble oxygenation and cardiotomy suction impair the host defense during cardiopulmonary bypass: a study in dogs. , 1987, The Annals of thoracic surgery.

[34]  S. Schmidt,et al.  A new perfusion circuit for the newborn with lung immaturity: extracorporeal CO2 removal via an umbilical arteriovenous shunt during apneic O2 diffusion. , 1984, Artificial organs.

[35]  B. Griffith,et al.  Arteriovenous ECMO for neonatal respiratory support. A study in perigestational lambs. , 1979, The Journal of thoracic and cardiovascular surgery.

[36]  R. Bowman,et al.  Artificial Placenta: Two Days of Total Extrauterine Support of the Isolated Premature Lamb Fetus , 1969, Science.

[37]  H. Britton,et al.  Maintenance of sheep fetuses by an extracorporeal circuit for periods up to 24 hours. , 1968, American journal of obstetrics and gynecology.

[38]  G. Chamberlain An artificial placenta , 1968 .

[39]  Callaghan Jc,et al.  STUDIES ON LAMBS OF THE DEVELOPMENT OF AN ARTIFICIAL PLACENTA. REVIEW OF NINE LONG-TERM SURVIVORS OF EXTRACORPOREAL CIRCULATION MAINTAINED IN A FLUID MEDIUM. , 1965 .

[40]  H. Britton,et al.  Survival of the foetal sheep at term following short periods of perfusion through the umbilical vessels , 1964, The Journal of physiology.

[41]  J. Callaghan,et al.  Studies of the first successful delivery of an unborn lamb after 40 minutes in the artificial placenta. , 1963, Canadian journal of surgery. Journal canadien de chirurgie.

[42]  R. Mccance,et al.  Ventures with an artificial placenta - I. Principles and preliminary results , 1962, Proceedings of the Royal Society of London. Series B. Biological Sciences.

[43]  R. Nyberg,et al.  A Technique for Perfusion of the Previable Human Fetus , 1958, Acta paediatrica.

[44]  B. Westin,et al.  Experimental studies of the human fetus in prolonged asphyxia. , 1954, Acta physiologica Scandinavica.

[45]  A. Philipp,et al.  Switch from venoarterial extracorporeal membrane oxygenation to arteriovenous pumpless extracorporeal lung assist. , 2010, The Annals of thoracic surgery.

[46]  J. Grotberg,et al.  Development of an artificial placenta I: pumpless arterio-venous extracorporeal life support in a neonatal sheep model. , 2009, Journal of pediatric surgery.

[47]  R. Guidoin,et al.  Pumpless respiratory assistance using a membrane oxygenator as an artificial placenta: a preliminary study in newborn and preterm lambs. , 1995, Journal of investigative surgery : the official journal of the Academy of Surgical Research.

[48]  A. Davenport,et al.  Comparison of the use of standard heparin and prostacyclin anticoagulation in spontaneous and pump-driven extracorporeal circuits in patients with combined acute renal and hepatic failure. , 1994, Nephron.

[49]  J. Atkinson,et al.  Extracorporeal membrane oxygenation in lambs through umbilical vessel perfusion: cardiac and hepatic complications. , 1992, Biology of the neonate.

[50]  V. Björk,et al.  From the spinning disc to the membrane oxygenator for open-heart surgery. , 1985, Scandinavian journal of thoracic and cardiovascular surgery.

[51]  R. Elgas,et al.  Response of distressed infants to partial bypass lung assist. , 1970, Transactions - American Society for Artificial Internal Organs.

[52]  G. Chamberlain An artificial placenta: the development of an extracorporeal system for maintenance of immature infants with respiratory problems. , 1968, American journal of obstetrics and gynecology.

[53]  J. Callaghan,et al.  STUDIES ON LAMBS OF THE DEVELOPMENT OF AN ARTIFICIAL PLACENTA. REVIEW OF NINE LONG-TERM SURVIVORS OF EXTRACORPOREAL CIRCULATION MAINTAINED IN A FLUID MEDIUM. , 1965, Canadian journal of surgery. Journal canadien de chirurgie.