Automated Detection and Measurement of Corneal Haze and Demarcation Line in Spectral-Domain Optical Coherence Tomography Images

Keratoconus is a progressive eye disease that may lead to significant loss of visual acuity. Corneal cross-linking (CXL) is a surgical procedure that halts the progression of keratoconus. One commonly used clinical indicator of CXL success, albeit being an indirect one, is the presence and depth of stromal demarcation line. In addition, corneal haze beyond the demarcation line can be an ominous sign of loss of corneal transparency, which is a much dreaded side effect of CXL. To date, ophthalmologists evaluate the presence and depth of the demarcation line and grade corneal haze using slit lamp biomicroscopy and/or optical coherence tomography (OCT). Interpreting the output of the former is very biased at best, while analyzing the information presented by the latter is time consuming, potentially error prone, and observer dependent. In this paper, we propose the first method that employs image analysis and machine learning to automatically detect and measure corneal haze and demarcation line presence and depth in OCT images. The automated method provides the user with haze statistics as well as visual annotation, reflecting the shape and location of the haze and demarcation line in the cornea. Our experimental results demonstrate the efficacy and effectiveness of the proposed techniques vis-a-vis manual measurements in a much faster, repeatable, and reproducible manner.

[1]  T. Seiler,et al.  Scheimpflug Records without Distortion – A Mythos? , 1999, Ophthalmic Research.

[2]  Qiang Chen,et al.  Individual Drusen Segmentation and Repeatability and Reproducibility of Their Automated Quantification in Optical Coherence Tomography Images , 2017, Translational vision science & technology.

[3]  Joseph A. Izatt,et al.  Robust automatic segmentation of corneal layer boundaries in SDOCT images using graph theory and dynamic programming , 2011, Biomedical optics express.

[4]  Yalin Zheng,et al.  Automatic segmentation of anterior segment optical coherence tomography images , 2013, Journal of biomedical optics.

[5]  Alejandro F. Frangi,et al.  Segmentation and Quantification for Angle-Closure Glaucoma Assessment in Anterior Segment OCT , 2017, IEEE Transactions on Medical Imaging.

[6]  G. Waring,et al.  High‐irradiance accelerated collagen crosslinking for the treatment of keratoconus: Six‐month results , 2014, Journal of cataract and refractive surgery.

[7]  David Huang,et al.  Automated detection of dilated capillaries on optical coherence tomography angiography. , 2017, Biomedical optics express.

[8]  Hossein Rabbani,et al.  Statistical Modeling of Retinal Optical Coherence Tomography , 2016, IEEE Transactions on Medical Imaging.

[9]  A. Atiya,et al.  Learning with Kernels: Support Vector Machines, Regularization, Optimization, and Beyond , 2005, IEEE Transactions on Neural Networks.

[10]  J. Németh,et al.  Shifting of the line of sight in keratoconus measured by a hartmann-shack sensor. , 2010, Ophthalmology.

[11]  Dacheng Tao,et al.  Speckle Reduction in 3D Optical Coherence Tomography of Retina by A-Scan Reconstruction , 2016, IEEE Trans. Medical Imaging.

[12]  Tos T. J. M. Berendschot,et al.  Use of anterior segment optical coherence tomography to study corneal changes after collagen cross-linking. , 2009, American journal of ophthalmology.

[13]  Peter S. Hersh,et al.  Natural history of corneal haze after collagen crosslinking for keratoconus and corneal ectasia: Scheimpflug and biomicroscopic analysis , 2010, Journal of cataract and refractive surgery.

[14]  A. C. Cheng,et al.  Corneal collagen cross-linking demarcation line depth assessed by Visante OCT After CXL for keratoconus and corneal ectasia. , 2012, Journal of refractive surgery.

[15]  David A. Clausi,et al.  A Novel Algorithm for Extraction of the Layers of the Cornea , 2009, 2009 Canadian Conference on Computer and Robot Vision.

[16]  A. Demirok,et al.  Evaluation of Corneal Stromal Demarcation Line after Two Different Protocols of Accelerated Corneal Collagen Cross-Linking Procedures Using Anterior Segment Optical Coherence Tomography and Confocal Microscopy , 2014, Journal of ophthalmology.

[17]  Steven Walfish,et al.  A review of statistical outlier methods , 2006 .

[18]  Farhad Hafezi,et al.  Corneal Cross-Linking-Induced Stromal Demarcation Line , 2006, Cornea.

[19]  G. Kymionis,et al.  Evaluation of the Corneal Collagen Cross-Linking Demarcation Line Profile Using Anterior Segment Optical Coherence Tomography , 2013, Cornea.

[20]  D. Varssano,et al.  Corneal Collagen Crosslinking: A Systematic Review , 2014, Ophthalmologica.

[21]  Guanglin Li,et al.  A Novel Technique for Robust and Fast Segmentation of Corneal Layer Interfaces Based on Spectral-Domain Optical Coherence Tomography Imaging , 2017, IEEE Access.

[22]  Amir-Hossein Karimi,et al.  Automated detection and cell density assessment of keratocytes in the human corneal stroma from ultrahigh resolution optical coherence tomograms , 2011, Biomedical optics express.

[23]  G. Kymionis,et al.  Correlation of the corneal collagen cross-linking demarcation line using confocal microscopy and anterior segment optical coherence tomography in keratoconic patients. , 2014, American journal of ophthalmology.

[24]  Sundaram Natarajan,et al.  Keratoconus , 2013, Indian journal of ophthalmology.

[25]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[26]  Keiichi Abe,et al.  Topological structural analysis of digitized binary images by border following , 1985, Comput. Vis. Graph. Image Process..

[27]  Shutao Li,et al.  Segmentation Based Sparse Reconstruction of Optical Coherence Tomography Images , 2017, IEEE Transactions on Medical Imaging.

[28]  R. Dennis Cook,et al.  Cross-Validation of Regression Models , 1984 .

[29]  J. Kent Information gain and a general measure of correlation , 1983 .