Liquid chromatography and supercritical fluid chromatography as alternative techniques to gas chromatography for the rapid screening of anabolic agents in urine.

This work describes the development of two methods involving supported liquid extraction (SLE) sample treatment followed by ultra-high performance liquid chromatography or ultra-high performance supercritical fluid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS and UHPSFC-MS/MS) for the screening of 43 anabolic agents in human urine. After evaluating different stationary phases, a polar-embedded C18 and a diol columns were selected for UHPLC-MS/MS and UHPSFC-MS/MS, respectively. Sample preparation, mobile phases and MS conditions were also finely tuned to achieve highest selectivity, chromatographic resolution and sensitivity. Then, the performance of these two methods was compared to the reference routine procedure for steroid analyses in anti-doping laboratories, which combines liquid-liquid extraction (LLE) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). For this purpose, urine samples spiked with the compounds of interest at five different concentrations were analyzed using the three analytical platforms. The retention and selectivity of the three techniques were very different, ensuring a good complementarity. However, the two new methods displayed numerous advantages. The overall procedure was much faster thanks to high throughput SLE sample treatment using 48-well plates and faster chromatographic analysis. Moreover, the highest sensitivity was attained using UHPLC-MS/MS with 98% of the doping agents detected at the lowest concentration level (0.1ng/mL), against 76% for UHPSFC-MS/MS and only 14% for GC-MS/MS. Finally, the weakest matrix effects were obtained with UHPSFC-MS/MS with 76% of the analytes displaying relative matrix effect between -20 and 20%, while the GC-MS/MS reference method displayed very strong matrix effects (over 100%) for all of the anabolic agents.

[1]  M. Mazzarino,et al.  A screening method for the simultaneous detection of glucocorticoids, diuretics, stimulants, anti-oestrogens, beta-adrenergic drugs and anabolic steroids in human urine by LC-ESI-MS/MS , 2008, Analytical and bioanalytical chemistry.

[2]  E. Lesellier,et al.  Characterization of five chemistries and three particle sizes of stationary phases used in supercritical fluid chromatography. , 2013, Journal of chromatography. A.

[3]  P. Kebarle,et al.  Dependence of ion intensity in electrospray mass spectrometry on the concentration of the analytes in the electrosprayed solution , 1993 .

[4]  Wilhelm Schänzer,et al.  Factors influencing the steroid profile in doping control analysis. , 2008, Journal of mass spectrometry : JMS.

[5]  Davy Guillarme,et al.  Modern analytical supercritical fluid chromatography using columns packed with sub-2 μm particles: a tutorial. , 2014, Analytica chimica acta.

[6]  Martial Saugy,et al.  Ultra high performance supercritical fluid chromatography coupled with tandem mass spectrometry for screening of doping agents. II: Analysis of biological samples. , 2015, Analytica chimica acta.

[7]  J. F. Deye,et al.  Effects of Column and Mobile Phase Polarity using Steroids as Probes in Packed-Column Supercritical Fluid Chromatography , 1991 .

[8]  Davy Guillarme,et al.  Comparison of ultra-high performance supercritical fluid chromatography and ultra-high performance liquid chromatography for the analysis of pharmaceutical compounds. , 2012, Journal of chromatography. A.

[9]  B. Matuszewski,et al.  Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS. , 2003, Analytical chemistry.

[10]  J. Veuthey,et al.  Maximizing kinetic performance in supercritical fluid chromatography using state-of-the-art instruments. , 2013, Journal of chromatography. A.

[11]  J. Hajšlová,et al.  Matrix-induced effects: a critical point in the gas chromatographic analysis of pesticide residues , 1998 .

[12]  D. Guillarme,et al.  Evaluation of stationary phases packed with superficially porous particles for the analysis of pharmaceutical compounds using supercritical fluid chromatography. , 2014, Journal of chromatography. A.

[13]  K. Linnet,et al.  Screening for anabolic steroids in urine of forensic cases using fully automated solid phase extraction and LC-MS-MS. , 2014, Journal of analytical toxicology.

[14]  Ó. Pozo,et al.  Analytical strategies based on mass spectrometric techniques for the study of steroid metabolism , 2014 .

[15]  Martial Saugy,et al.  Fast and sensitive supercritical fluid chromatography - tandem mass spectrometry multi-class screening method for the determination of doping agents in urine. , 2016, Analytica chimica acta.

[16]  B. Le Bizec,et al.  Analysis of glucuronide and sulfate steroids in urine by ultra-high-performance supercritical-fluid chromatography hyphenated tandem mass spectrometry , 2015, Analytical and Bioanalytical Chemistry.

[17]  J. Veuthey,et al.  Quantification of glucuronidated and sulfated steroids in human urine by ultra-high pressure liquid chromatography quadrupole time-of-flight mass spectrometry , 2011, Analytical and bioanalytical chemistry.

[18]  H. Yoo,et al.  LC-ESI/MS/MS method for rapid screening and confirmation of 44 exogenous anabolic steroids in human urine , 2011, Analytical and bioanalytical chemistry.

[19]  R. Massé,et al.  Studies on anabolic steroids. I. Integrated methodological approach to the gas chromatographic-mass spectrometric analysis of anabolic steroid metabolites in urine. , 1989, Journal of chromatography.

[20]  Jitka Zrostlíková,et al.  Matrix effects in (ultra)trace analysis of pesticide residues in food and biotic matrices. , 2003, Journal of chromatography. A.

[21]  A. Butch,et al.  Detection of prohibited substances by liquid chromatography tandem mass spectrometry for sports doping control. , 2012, Methods in molecular biology.

[22]  Jaeick Lee,et al.  Sensitivity of GC-EI/MS, GC-EI/MS/MS, LC-ESI/MS/MS, LC-Ag(+) CIS/MS/MS, and GC-ESI/MS/MS for analysis of anabolic steroids in doping control. , 2015, Drug testing and analysis.

[23]  A. M. Gillespie,et al.  Explanation of the matrix-induced chromatographic response enhancement of organophosphorus pesticides during open tubular column gas chromatography with splitless or hot on-column injection and flame photometric detection , 1993 .

[24]  Yan Li,et al.  Compensation for matrix effects in the gas chromatography-mass spectrometry analysis of 186 pesticides in tea matrices using analyte protectants. , 2012, Journal of chromatography. A.

[25]  N. Sethi,et al.  Supercritical fluid chromatography-A Hybrid of GC and LC , 2010 .

[26]  Davy Guillarme,et al.  Supercritical fluid chromatography in pharmaceutical analysis. , 2015, Journal of pharmaceutical and biomedical analysis.

[27]  Ó. Pozo,et al.  Screening for anabolic steroids in sports: analytical strategy based on the detection of phase I and phase II intact urinary metabolites by liquid chromatography tandem mass spectrometry. , 2015, Journal of chromatography. A.

[28]  J. Segura,et al.  Fast screening of anabolic steroids and other banned doping substances in human urine by gas chromatography/tandem mass spectrometry. , 2002, Journal of mass spectrometry : JMS.

[29]  Davy Guillarme,et al.  Coupling state-of-the-art supercritical fluid chromatography and mass spectrometry: from hyphenation interface optimization to high-sensitivity analysis of pharmaceutical compounds. , 2014, Journal of chromatography. A.

[30]  J. Veuthey,et al.  Analytical Strategies for Doping Control Purposes: Needs, Challenges, and Perspectives. , 2016, Analytical chemistry.

[31]  Davy Guillarme,et al.  The use of columns packed with sub-2 µm particles in supercritical fluid chromatography , 2014 .

[32]  C. Welch,et al.  Chromatographic resolution of closely related species: drug metabolites and analogs. , 2014, Journal of separation science.

[33]  Caroline West,et al.  The many faces of packed column supercritical fluid chromatography--a critical review. , 2015, Journal of chromatography. A.

[34]  R. Massé,et al.  Studies on anabolic steroids : I. Integrated methodological approach to the gas chromatographic-mass spectrometric analysis of anabolic steroid metabolites in urine , 1989 .

[35]  Martial Saugy,et al.  Ultra high performance supercritical fluid chromatography coupled with tandem mass spectrometry for screening of doping agents. I: Investigation of mobile phase and MS conditions. , 2015, Analytica chimica acta.

[36]  L. Nováková,et al.  A review of current trends and advances in modern bio-analytical methods: chromatography and sample preparation. , 2009, Analytica chimica acta.

[37]  Achille Cappiello,et al.  Overcoming matrix effects in liquid chromatography-mass spectrometry. , 2008, Analytical chemistry.