Optimization of conformal thoracic radiotherapy using cone-beam CT imaging for treatment verification.

PURPOSE Megavoltage cone-beam computed tomography (MVCBCT) has been proposed for treatment verification in conformal radiotherapy. However, the doses required for such imaging may compromise the quality of the delivered dose distribution. The present paper explores the effect of cone-beam imaging on dose homogeneity and critical organ dose and the use of our new tool, adapted intensity-modulated radiation therapy (AIMRT). METHODS AND MATERIALS Three types of treatment plans were devised (3D-CRT [three-dimensional conformal radiotherapy], IMRT [intensity-modulated radiotherapy], and AIMRT) based on 4 patients with thoracic malignancies. MVCBCT fields were then integrated into the plans. The MVCBCT technique used 21 imaging portals at 10 degrees intervals. The MVCBCT apertures were shaped to conform to the planning target volume with a 6-mm margin. In a second set of plans, the field size was expanded by a further 2 cm. The unoptimized MVCBCT dose distribution was incorporated into the IMRT plan using AIMRT. RESULTS Normal-tissue complication probability with MVCBCT is acceptable for all plans at the 66.6 Gy level, but exceeds tolerance for both 3D-CRT alone and 3D-CRT with MVCBCT at higher doses. In contrast, the use of AIMRT planning with MVCBCT allowed safe dose escalation to 85 Gy. Expanding the MVCBCT aperture provided better anatomic visibility with an acceptable lung dose. The results using IMRT with MVCBCT fell between the values measured for 3D-CRT and AIMRT with MVCBCT. CONCLUSION The present study is the first to demonstrate that MVCBCT can be incorporated into 3D-CRT and IMRT planning with minimal effect on planning target volume homogeneity and dose to critical structures. This paves the way for highly conformal radiotherapy at greater doses delivered with increased confidence and safety.

[1]  M. Goitein,et al.  Fitting of normal tissue tolerance data to an analytic function. , 1991, International journal of radiation oncology, biology, physics.

[2]  J Dudson,et al.  A feasibility study for megavoltage cone beam CT using a commercial EPID. , 1998, Physics in medicine and biology.

[3]  Icru Prescribing, recording, and reporting photon beam therapy , 1993 .

[4]  M. V. van Herk,et al.  Physical aspects of a real-time tumor-tracking system for gated radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[5]  S. Spirou,et al.  A gradient inverse planning algorithm with dose-volume constraints. , 1998, Medical physics.

[6]  K. Ohara,et al.  Irradiation synchronized with respiration gate. , 1989, International journal of radiation oncology, biology, physics.

[7]  W Swindell,et al.  Computed tomography with a linear accelerator with radiotherapy applications. , 1983, Medical physics.

[8]  R Mohan,et al.  A comprehensive three-dimensional radiation treatment planning system. , 1988, International journal of radiation oncology, biology, physics.

[9]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[10]  S Webb,et al.  A cone-beam megavoltage CT scanner for treatment verification in conformal radiotherapy. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[11]  P. Munro,et al.  A review of electronic portal imaging devices (EPIDs). , 1992, Medical physics.

[12]  K. Nakagawa,et al.  Technological features and clinical feasibility of megavoltage CT scanning , 1992, European Radiology.

[13]  K Nakagawa,et al.  Real-time beam monitoring in dynamic conformation therapy. , 1994, International journal of radiation oncology, biology, physics.

[14]  A Brahme,et al.  Radiotherapeutic computed tomography with scanned photon beams. , 1987, International journal of radiation oncology, biology, physics.

[15]  P. Munro,et al.  Portal Imaging Technology: Past, Present, and Future. , 1995, Seminars in radiation oncology.

[16]  C. Ramsey,et al.  Clinical efficacy of respiratory gated conformal radiation therapy. , 1999, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[17]  D. G. Lewis,et al.  A megavoltage CT scanner for radiotherapy verification. , 1992, Physics in medicine and biology.

[18]  G J Kutcher,et al.  Probability of radiation-induced complications for normal tissues with parallel architecture subject to non-uniform irradiation. , 1993, Medical physics.

[19]  C C Ling,et al.  Cone-beam CT with megavoltage beams and an amorphous silicon electronic portal imaging device: potential for verification of radiotherapy of lung cancer. , 2002, Medical physics.

[20]  S. Spirou,et al.  Dose calculation for photon beams with intensity modulation generated by dynamic jaw or multileaf collimations. , 1994, Medical physics.

[21]  J A Purdy,et al.  Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC) , 1999, International journal of radiation oncology, biology, physics.