Modifications of the HEX program for fast automatic resolution of PIXE-spectra

The computer program ‘HEX’ for resolving PIXE-spectra has been modified. By irradiating standard foils, the escape peak ratios for x-ray peaks in the energy interval 3.3-10.6 keV have been measured. The results have been compared with theoretical calculations and experimental results of other research groups. The escape peaks have been included in the computer code. Pile-up peaks in the x-ray spectrum are also fitted by the modified computer program. This procedure is independent of the count rate and the pile-up interval. In addition, an effective routine for rejecting small x-ray peaks has been developed.

[1]  E. Steinbauer Calculation of pile-up intensities in PIXE spectra obtained by triggered beam pulsing , 1981 .

[2]  R. Akselsson,et al.  Performance of an On-Demand Beam Excitation System for PIXE Analysis , 1982 .

[3]  S. Reed,et al.  Escape peaks and internal fluorescence in X-ray spectra recorded with lithium drifted silicon detectors , 1972 .

[4]  Roland Akselsson,et al.  REX: A Computer Program for PIXE Spectrum Resolution of Aerosols , 1975 .

[5]  D. Marquardt An Algorithm for Least-Squares Estimation of Nonlinear Parameters , 1963 .

[6]  D. Cohen,et al.  Thick target pixe analysis and yield curve calculations , 1981 .

[7]  F. Adams,et al.  A method for the accurate description of the full-energy peaks in non-linear least-squares analysis of x-ray spectra , 1977 .

[8]  P. Axel Intensity Corrections for Iodine X-Rays Escaping from Sodium Iodide Scintillation Crystals , 1954 .

[9]  P. Statham Escape peaks and internal fluorescence for a Si(Li) detector and general geometry , 1976 .

[10]  J. Campbell,et al.  Analytic approximations to peak shapes produced by Ge(Li) and Si(Li) spectrometers , 1975 .

[11]  A. Langenberg,et al.  An evaluation of K-shell fluorescence yields; observation of outer-shell effects , 1979 .

[12]  W. Veigele,et al.  Photon cross sections from 0.1 keV to 1 MeV for elements Z = 1 to Z = 94* , 1973 .

[13]  Roland Akselsson,et al.  Non-Linear Least Squares Analysis of Proton-Induced X-Ray Emission Data , 1974 .

[14]  P. Sioshansi,et al.  Escape peak losses in Si(Li) detectors , 1979 .

[15]  J. H. Scofield,et al.  Exchange corrections of K x-ray emission rates , 1974 .

[16]  Roland Akselsson,et al.  REX - A Computer Programme for PIXE Analysis , 1977 .

[17]  S. Reed,et al.  Quantitative electron microprobe analysis using a lithium drifted silicon detector , 1973 .