Uncertainty quantification of microclimate variables in building energy models

The last decade has seen a surge in the need for uncertainty analysis (UA) for building energy assessment. The rigorous determination of uncertainty in model parameters is a vital but often overlooked part of UA. To undertake this, one has to turn one's attention to a thriving area in engineering statistics that focuses on uncertainty quantification (UQ) for short. This paper applies dedicated methods and theories that are emerging in this area of statistics to the field of building energy models, and specifically to the microclimate variables embedded in them. We argue that knowing the uncertainty in these variables is a vital prerequisite for ensuing UA of whole building behaviour. Indeed, significant discrepancies have been observed between the predicted and measured state variables of building microclimates. This paper uses a set of approaches from the growing UQ arsenal, mostly regression-based methods, to develop statistical models that quantify the uncertainties in the following most significant microclimate variables: local temperature, wind speed, wind pressure and solar irradiation. These are the microclimate variables used by building energy models to define boundary conditions that encapsulate the interaction of the building with the surrounding physical environment. Although our analysis is generically applicable to any of the current energy models, we will base our UQ examples on the energy model used in EnergyPlus.

[1]  Valéry Masson,et al.  A Physically-Based Scheme For The Urban Energy Budget In Atmospheric Models , 2000 .

[2]  G. D. Wyss,et al.  A user`s guide to LHS: Sandia`s Latin Hypercube Sampling Software , 1998 .

[3]  M. Santamouris,et al.  On the estimation of wind speed in urban canyons for ventilation purposes—Part 1: Coupling between the undisturbed wind speed and the canyon wind , 2008 .

[4]  Keith W. Oleson,et al.  Parameterization of Urban Characteristics for Global Climate Modeling , 2010 .

[5]  Sonja Kuhnt,et al.  Design and analysis of computer experiments , 2010 .

[6]  F. Désalmand Meteorology today : An introduction to weather, Climate, and the environment , 1998 .

[7]  Godfried Augenbroe,et al.  APPLICATION OF PROBABILISTIC SIMULATION AND BAYESIAN DECISION THEORY IN THE SELECTION OF MOLD REMEDIATION ACTIONS , 2007 .

[8]  N. Klitsikas,et al.  The effect of the Athens heat island on air conditioning load , 2000 .

[9]  M. S. De Wit,et al.  Uncertainty in predictions of thermal comfort in buildings , 2001 .

[10]  W. J. DeCoursey,et al.  Introduction: Probability and Statistics , 2003 .

[11]  K. Oleson,et al.  An Urban Parameterization for a Global Climate Model. Part I: Formulation and Evaluation for Two Cities , 2008 .

[12]  Mariana Vertenstein,et al.  An urban parameterization for a global climate model. Part II: Sensitivity to input parameters and the simulated urban heat island in offline simulations , 2008 .

[13]  Refrigerating ASHRAE handbook of fundamentals , 1967 .

[14]  Lulu Kang,et al.  Regression-Based Inverse Distance Weighting With Applications to Computer Experiments , 2011, Technometrics.

[15]  Timothy R. Oke,et al.  Evaluation of the Town Energy Balance (TEB) Scheme with Direct Measurements from Dry Districts in Two Cities , 2002 .

[16]  B. D. Hunn,et al.  Determination of average ground reflectivity for solar collectors , 1976 .

[17]  S. Chandra,et al.  Correlations for pressure distribution on buildings and calculation of natural-ventilation airflow , 1988 .

[18]  Godfried Augenbroe,et al.  A stochastic model based energy management system for off-grid solar houses , 2012 .

[19]  Huafen Hu,et al.  Risk-conscious design of off-grid solar energy houses , 2009 .

[20]  V. Masson,et al.  Inclusion of a Drag Approach in the Town Energy Balance (TEB) Scheme: Offline 1D Evaluation in a Street Canyon , 2008 .

[21]  Jon A. Peterka,et al.  AVERAGED PRESSURE COEFFICIENTS FOR RECTANGULAR BUILDINGS , 1980 .

[22]  J. C. Phaff,et al.  Pressure simulation program , 1995 .

[23]  J. Y. Liu,et al.  Assessing the effect of land use/land cover change on the change of urban heat island intensity , 2007 .

[24]  Godfried Augenbroe,et al.  Analysis of uncertainty in building design evaluations and its implications , 2002 .

[25]  Calmet Meteorological Model A User's Guide for the , 1999 .

[26]  Yeonsook Heo,et al.  Quantitative risk management for energy retrofit projects , 2013 .

[27]  A. Arnfield Two decades of urban climate research: a review of turbulence, exchanges of energy and water, and the urban heat island , 2003 .

[28]  Joseph Andrew Clarke,et al.  Simulation-assisted control in building energy management systems , 2002 .

[29]  L. K. Norford,et al.  Two-to-one discrepancy between measured and predicted performance of a ‘low-energy’ office building: insights from a reconciliation based on the DOE-2 model , 1994 .

[30]  Yeonsook Heo,et al.  Calibration of building energy models for retrofit analysis under uncertainty , 2012 .

[31]  Richard J. Beckman,et al.  A Comparison of Three Methods for Selecting Values of Input Variables in the Analysis of Output From a Computer Code , 2000, Technometrics.

[32]  Bing Liu,et al.  U.S. Department of Energy Commercial Reference Building Models of the National Building Stock , 2011 .

[33]  P. Ineichen,et al.  A new simplified version of the perez diffuse irradiance model for tilted surfaces , 1987 .