Dynamic Stability Enhancement of a DC-Segmented AC Power System Via HVDC Operating-Point Adjustment

Hopf bifurcation phenomenon of a power system results in oscillatory dynamics which can lead to instabilities in the system. Therefore, it is desirable to operate the system such that a sufficient margin to Hopf bifurcation is ensured. This paper presents a methodology based on the adjustment of the setpoint values of the HVDC link controllers, to prevent instability or increase the stability margin of the system subject to Hopf bifurcation. In this paper, the first-order sensitivities of the Hopf stability margin to the setpoint values of the HVDC links are presented. These sensitivities identify the optimum direction to change the HVDC setpoints to steer the system away from instability, increase the stability margin, and improve the damping of oscillatory modes. The proposed method is evaluated on various system configurations subject to Hopf bifurcation phenomena caused by a variety of events, such as load and line impedance variations. Simulation results show that at the optimum operating point, for a variety of Hopf bifurcations, the stability margin and damping of the oscillatory modes improve.

[1]  C. A. Canizares,et al.  Limitations of assigning general critical values to voltage stability indices in Voltage-Stability-Constrained optimal power flows , 2012, 2012 IEEE International Conference on Power System Technology (POWERCON).

[2]  L.O. Barthold,et al.  Upgrading AC transmission to DC for maximum power transfer capacity , 2008, 2008 12th International Middle-East Power System Conference.

[3]  R. Schlueter,et al.  Inertial, Governor, and AGC/Economic Dispatch Load Flow Simulations of Loss of Generation Contingencies , 1985, IEEE Power Engineering Review.

[4]  A.A.P. Lerm Control of hopf bifurcation in power systems via a generation redispatch , 2001, 2001 IEEE Porto Power Tech Proceedings (Cat. No.01EX502).

[5]  A. Lerm,et al.  Avoiding hopf bifurcations in power systems via set-points tuning , 2004 .

[6]  Lennart Söder,et al.  Active and reactive power control of a VSC-HVdc , 2008 .

[7]  R. Fischl,et al.  Local bifurcation in power systems: theory, computation, and application , 1995, Proc. IEEE.

[8]  Federico Milano,et al.  Power System Modelling and Scripting , 2010 .

[9]  Shaobu Wang,et al.  On-line control of Hopf bifurcations in power systems , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[10]  Zhenyu Huang,et al.  Improving small signal stability through operating point adjustment , 2010, IEEE PES General Meeting.

[11]  Dennis Woodford,et al.  Softening the Blow of Disturbances , 2008, IEEE Power and Energy Magazine.

[12]  Nadarajah Mithulananthan,et al.  Comparison of PSS, SVC, and STATCOM controllers for damping power system oscillations , 2003 .

[13]  Peter W. Sauer,et al.  Power System Dynamics and Stability , 1997 .

[14]  A. Zecevic,et al.  The effects of generation redispatch on Hopf bifurcations in electric power systems , 2002 .

[15]  F. Alvarado,et al.  Sensitivity of Hopf bifurcations to power system parameters , 1992, [1992] Proceedings of the 31st IEEE Conference on Decision and Control.

[16]  Peter W. Sauer,et al.  The effect of automatic voltage regulation on the bifurcation evolution in power systems , 1996 .

[17]  Jovica V. Milanovic,et al.  Comparison of dynamic performance of meshed networks with different types of HVDC lines , 2010 .

[18]  Ronald G. Harley,et al.  Suppressing subsynchronous resonance with static filters , 1981 .

[19]  A.A.P. Lerm Control of Hopf bifurcation in multi-area power systems via a secondary voltage regulation scheme , 2002, IEEE Power Engineering Society Summer Meeting,.

[20]  T. Smed,et al.  Feasible eigenvalue sensitivity for large power systems , 1993 .

[21]  Sam Kodsi,et al.  Application of a Stability-Constrained Optimal Power Flow to Tuning of Oscillation Controls in Competitive Electricity Markets , 2007, IEEE Transactions on Power Systems.