The prospect of a small-sized vibrating flow pump for an artificial heart

A small-sized blood pump is required for a high-performance total artificial heart. From the viewpoint of the implantation, anatomical fitting into the cavity from which the heart has been removed is very important for the design of the total artificial heart. A small, high-performance blood pump is desired for a totally implantable artificial heart system. A miniaturized blood pump is not easy to achieve because of its driving mechanism and material endurance. The stroke volume is necessarily decreased by the downsizing of a volume-displacing pump, such as a sac-type blood pump. Similarly, the centrifugal force is decreased by the downsizing of a centrifugal pump. The vibrating flow pump (VFP) is one of the inertia-type pumps, but it can make a volume flow wave by its vibrating motion. The short stroke volume and high rate of driving may be notable characteristics for the minimization of the pump. In this study, a prototype VFP was made for a basic performance test. It showed adequate performance for left ventricular assistance and also showed potential for more downsizing. The estimation of the design and the driving stroke of the vibrating tube may be the next step for an advanced VFP system.

[1]  D. Bergel,et al.  Pulmonary Vascular Impedance in the Dog , 1965, Circulation research.

[2]  T Chinzei,et al.  Present status of the total artificial heart at the University of Tokyo. , 1999, Artificial organs.

[3]  A. Furness,et al.  To pulse or not to pulse. , 1980, The Annals of thoracic surgery.

[4]  C D Bertram,et al.  A general method of determining the frequency-dependent propagation coefficient and characteristic impedance of an artery in the presence of reflections. , 1992, Journal of biomechanical engineering.

[5]  T Yambe,et al.  Carotid arterial impedance during oscillated blood flow. , 1994, Artificial organs.

[6]  L H Edmunds,et al.  Organ blood flow during pulsatile cardiopulmonary bypass. , 1974, Journal of applied physiology.

[7]  Shin-ichi Kobayashi Arterial impedance on the chronic examination of left ventricular assist circulation using oscillated blood flow , 1995 .

[8]  T Yambe,et al.  Development of Vibrating flow Pump for Left Ventricular Assist Circulation , 1998, The International journal of artificial organs.

[9]  井街宏 Development of artificial valve (jellyfish valve) for artificial heart blood pump with a new concept , 1989 .

[10]  T Yambe,et al.  Hemolysis test of disposable type vibrating flow pump. , 1997, Artificial organs.

[11]  Tomoyuki Yambe,et al.  Arterial impedance during the cardiopulmonary bypass using oscillated blood flow. , 1994 .

[12]  Tomoyuki Yambe,et al.  Arterial Resonance Inferred from Analysis of Arterial Impedance , 1998 .

[13]  T Yambe,et al.  Experimental study of physiological advantages of assist circulation using oscillated blood flow. , 1995, Artificial organs.