Kinematic Analysis and Optimization of a Novel Robot for Surgical Tool Manipulation

The size and limited dexterity of current surgical robotic systems are factors that limit their usefulness. To improve the level of assimilation of surgical robots in minimally invasive surgery (MIS), a compact, lightweight surgical robotic positioning mechanism with four degrees of freedom (DOFs) (three rotational DOFs and one translation DOF) is proposed in this paper. This spatial mechanism based on a bevel-gear wrist is remotely driven with three rotation axes intersecting at a remote rotation center (the MIS entry port). Forward and inverse kinematics are derived, and these are used for optimizing the mechanism structure given workspace requirements. By evaluating different spherical geared configurations with various link angles and pitch angles, an optimal design is achieved, which performs surgical tool positioning throughout the desired kinematic workspace while occupying a small space bounded by a hemisphere of radius 13.7 cm. This optimized workspace conservatively accounts for collision avoidance between the patient and robot or internally between the robot links. This resultant mechanism is highly compact and yet has the dexterity to cover the extended workspace typically required in telesurgery. It can also be used for tool tracking and skills assessment. Due to the linear nature of the gearing relationships, it may also be well suited for implementing force feedback for telesurgery.

[1]  Yulun Wang,et al.  Robotic surgery - the transatlantic case , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[2]  Blake Hannaford,et al.  Kinematic optimization of a spherical mechanism for a minimally invasive surgical robot , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[3]  Nassir Navab,et al.  A New Robotic System for Visually Controlled Percutaneous Inerventions under CT Fluoroscopy , 2000, MICCAI.

[4]  P. Berkelman,et al.  A Compact, Modular, Teleoperated Robotic Minimally Invasive Surgery System , 2006, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006..

[5]  John Kenneth Salisbury,et al.  The Intuitive/sup TM/ telesurgery system: overview and application , 2000, Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065).

[6]  Blake Hannaford,et al.  Optimization of a spherical mechanism for a minimally invasive surgical robot: theoretical and experimental approaches , 2006, IEEE Transactions on Biomedical Engineering.

[7]  J. M. Sackier,et al.  Robotically assisted laparoscopic surgery , 2008, Surgical Endoscopy.

[8]  Philippe Cinquin,et al.  LER: the light endoscope robot , 2003, Proceedings 2003 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2003) (Cat. No.03CH37453).

[9]  Lung-Wen Tsai,et al.  The kinematics of spatial robotic bevel-gear trains , 1988, IEEE J. Robotics Autom..

[10]  Tobias Ortmaier,et al.  A new robot for force control in minimally invasive surgery , 2004, 2004 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (IEEE Cat. No.04CH37566).

[11]  S. Shankar Sastry,et al.  A laparoscopic telesurgical workstation , 1999, IEEE Trans. Robotics Autom..

[12]  Russell H. Taylor,et al.  A telerobotic assistant for laparoscopic surgery , 1995 .

[13]  Russell H. Taylor,et al.  Medical robotics in computer-integrated surgery , 2003, IEEE Trans. Robotics Autom..

[14]  Jacques Marescaux,et al.  Transatlantic robot-assisted telesurgery , 2001, Nature.

[15]  Nicola Pio Belfiore An Atlas of Remote Actuated Bevel Gear Wrist Mechanisms of up to Nine Links , 1993, Int. J. Robotics Res..

[16]  John J. Craig,et al.  Introduction to Robotics Mechanics and Control , 1986 .

[17]  Ferdinand Freudenstein,et al.  Kinematic Analysis of Robotic Bevel-Gear Trains , 1984 .

[18]  Ferdinand Freudenstein,et al.  An Application of Boolean Algebra to the Motion of Epicyclic Drives , 1971 .

[19]  Arthur C. Sanderson,et al.  A novel concentric multilink spherical joint with parallel robotics applications , 1994, Proceedings of the 1994 IEEE International Conference on Robotics and Automation.

[20]  Andrew P. Murray,et al.  SYSTEMATIC PROCESS FOR CONSTRUCTING SPHERICAL FOUR-BAR MECHANISMS , 2005 .

[21]  Y. Matsuoka,et al.  Robotics for surgery. , 1999, Annual review of biomedical engineering.

[22]  Blake Hannaford,et al.  Hybrid analysis of a spherical mechanism for a minimally invasive surgical (MIS) robot--design concepts for multiple optimizations. , 2006, Studies in health technology and informatics.

[23]  Blake Hannaford,et al.  The BlueDRAGON - a system for measuring the kinematics and dynamics of minimally invasive surgical tools in-vivo , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[24]  C. P. Day,et al.  Kinematic Design and Analysis of Coupled Planetary Bevel-Gear Trains , 1983 .

[25]  S. Shankar Sastry,et al.  Robotics for telesurgery: second generation Berkeley/UCSF laparoscopic telesurgical workstation and looking towards the future applications , 2003, Ind. Robot.

[26]  A. Guerrouad,et al.  SMOS: stereotaxical microtelemanipulator for ocular surgery , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.