A Simple, Inexpensive Device for Nucleic Acid Amplification without Electricity—Toward Instrument-Free Molecular Diagnostics in Low-Resource Settings

Background Molecular assays targeted to nucleic acid (NA) markers are becoming increasingly important to medical diagnostics. However, these are typically confined to wealthy, developed countries; or, to the national reference laboratories of developing-world countries. There are many infectious diseases that are endemic in low-resource settings (LRS) where the lack of simple, instrument-free, NA diagnostic tests is a critical barrier to timely treatment. One of the primary barriers to the practicality and availability of NA assays in LRS has been the complexity and power requirements of polymerase chain reaction (PCR) instrumentation (another is sample preparation). Methodology/Principal Findings In this article, we investigate the hypothesis that an electricity-free heater based on exothermic chemical reactions and engineered phase change materials can successfully incubate isothermal NA amplification assays. We assess the heater's equivalence to commercially available PCR instruments through the characterization of the temperature profiles produced, and a minimal method comparison. Versions of the prototype for several different isothermal techniques are presented. Conclusions/Significance We demonstrate that an electricity-free heater based on exothermic chemical reactions and engineered phase change materials can successfully incubate isothermal NA amplification assays, and that the results of those assays are not significantly different from ones incubated in parallel in commercially available PCR instruments. These results clearly suggest the potential of the non-instrumented nucleic acid amplification (NINA) heater for molecular diagnostics in LRS. When combined with other innovations in development that eliminate power requirements for sample preparation, cold reagent storage, and readout, the NINA heater will comprise part of a kit that should enable electricity-free NA testing for many important analytes.

[1]  Angelika Niemz,et al.  Point-of-care nucleic acid testing for infectious diseases. , 2011, Trends in biotechnology.

[2]  D. Moore,et al.  The MIT D-lab electricity-free PortaTherm™ incubator for remote testing with the QuantiFERON®-TB Gold In-Tube assay. , 2010, The international journal of tuberculosis and lung disease : the official journal of the International Union against Tuberculosis and Lung Disease.

[3]  Joseph D Tucker,et al.  Accelerating worldwide syphilis screening through rapid testing: a systematic review. , 2010, The Lancet. Infectious diseases.

[4]  Xiliang Wang,et al.  Development and application of lateral flow test strip technology for detection of infectious agents and chemical contaminants: a review , 2010, Analytical and bioanalytical chemistry.

[5]  N. Arunrut,et al.  Rapid and sensitive detection of Penaeus monodon nucleopolyhedrovirus (PemoNPV) by loop-mediated isothermal amplification combined with a lateral-flow dipstick. , 2010, Molecular and cellular probes.

[6]  Ben Hatano,et al.  LAMP using a disposable pocket warmer for anthrax detection, a highly mobile and reliable method for anti-bioterrorism. , 2010, Japanese journal of infectious diseases.

[7]  A. Castagnaro,et al.  Rapid and sensitive detection of Citrus Bacterial Canker by loop-mediated isothermal amplification combined with simple visual evaluation methods , 2010, BMC Microbiology.

[8]  Y. Mori,et al.  Loop-mediated isothermal amplification (LAMP): a rapid, accurate, and cost-effective diagnostic method for infectious diseases , 2009, Journal of Infection and Chemotherapy.

[9]  Yi-Wei Tang,et al.  Emerging Molecular Assays for Detection and Characterization of Respiratory Viruses , 2009, Clinics in Laboratory Medicine.

[10]  T P D Andrade,et al.  Development of a method for the detection of infectious myonecrosis virus by reverse-transcription loop-mediated isothermal amplification and nucleic acid lateral flow hybrid assay. , 2009, Journal of fish diseases.

[11]  BH Weigl,et al.  Simplicity of use: a critical feature for widespread adoption of diagnostic technologies in low-resource settings , 2009, Expert review of medical devices.

[12]  D. Rudolph,et al.  Sequence‐specific detection method for reverse transcription, loop‐mediated isothermal amplification of HIV‐1 , 2009, Journal of medical virology.

[13]  Qian Gao,et al.  Cross-Priming Amplification for Rapid Detection of Mycobacterium tuberculosis in Sputum Specimens , 2009, Journal of Clinical Microbiology.

[14]  Frank F Bier,et al.  Helicase-dependent amplification: use in OnChip amplification and potential for point-of-care diagnostics , 2009, Expert review of molecular diagnostics.

[15]  Frontiers in clinical diagnostics. Abstracts of the 41st Oak Ridge Conference, April 16-17, 2009, Baltimore, Maryland, USA. , 2009, Clinical chemistry.

[16]  Bernhard Weigl,et al.  Towards non- and minimally instrumented, microfluidics-based diagnostic devices. , 2008, Lab on a chip.

[17]  P. Newton,et al.  Simple, rapid and sensitive detection of Orientia tsutsugamushi by loop-isothermal DNA amplification. , 2008, Transactions of the Royal Society of Tropical Medicine and Hygiene.

[18]  D. Rudolph,et al.  Rapid detection of HIV-1 by reverse-transcription, loop-mediated isothermal amplification (RT-LAMP). , 2008, Journal of virological methods.

[19]  Phillip I. Tarr,et al.  Loop-Mediated Isothermal Amplification Assay for Rapid Detection of Common Strains of Escherichia coli , 2008, Journal of Clinical Microbiology.

[20]  Yasuyoshi Mori,et al.  Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products , 2008, Nature Protocols.

[21]  Chii-Wann Lin,et al.  Compact optical diagnostic device for isothermal nucleic acids amplification , 2008, Sensors and Actuators B: Chemical.

[22]  K. Gruden,et al.  Alternative DNA amplification methods to PCR and their application in GMO detection: a review , 2008 .

[23]  E. Matovu,et al.  African trypanosomiasis: Sensitive and rapid detection of the sub-genus Trypanozoon by loop-mediated isothermal amplification (LAMP) of parasite DNA , 2007, International Journal for Parasitology.

[24]  Eun-Taek Han,et al.  Detection of Four Plasmodium Species by Genus- and Species-Specific Loop-Mediated Isothermal Amplification for Clinical Diagnosis , 2007, Journal of Clinical Microbiology.

[25]  Mitsuhiro Ebara,et al.  Dual magnetic-/temperature-responsive nanoparticles for microfluidic separations and assays. , 2007, Langmuir : the ACS journal of surfaces and colloids.

[26]  T. Yoshikawa,et al.  Direct detection of human herpesvirus 6 DNA in serum by the loop-mediated isothermal amplification method. , 2007, Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology.

[27]  J. Isaac-Renton,et al.  Molecular methods used in clinical laboratory: prospects and pitfalls. , 2007, FEMS immunology and medical microbiology.

[28]  Rosanna W. Peeling,et al.  Why do we need quality-assured diagnostic tests for sexually transmitted infections? , 2006, Nature Reviews Microbiology.

[29]  F. Girosi,et al.  Reducing the burden of childhood malaria in Africa: the role of improved , 2006, Nature.

[30]  S. S. Olmsted,et al.  Requirements for high impact diagnostics in the developing world , 2006, Nature.

[31]  Kristen L. Helton,et al.  Microfluidic Overview of Global Health Issues Microfluidic Diagnostic Technologies for Global Public Health , 2006 .

[32]  Yi Guan,et al.  Sensitive and inexpensive molecular test for falciparum malaria: detecting Plasmodium falciparum DNA directly from heat-treated blood by loop-mediated isothermal amplification. , 2006, Clinical chemistry.

[33]  T. Notomi,et al.  A simple method for the detection of measles virus genome by loop‐mediated isothermal amplification (LAMP) , 2005, Journal of medical virology.

[34]  Tsugunori Notomi,et al.  Development and Evaluation of a Novel Loop-Mediated Isothermal Amplification Method for Rapid Detection of Severe Acute Respiratory Syndrome Coronavirus , 2004, Journal of Clinical Microbiology.

[35]  Y. Mori,et al.  Detection of loop-mediated isothermal amplification reaction by turbidity derived from magnesium pyrophosphate formation. , 2001, Biochemical and biophysical research communications.

[36]  T. Notomi,et al.  Loop-mediated isothermal amplification of DNA. , 2000, Nucleic acids research.

[37]  M. Neumaier,et al.  Fundamentals of quality assessment of molecular amplification methods in clinical diagnostics. International Federation of Clinical Chemistry Scientific Division Committee on Molecular Biology Techniques. , 1998, Clinical chemistry.