Optoacoustic, Noninvasive, Real-Time, Continuous Monitoring of Cerebral Blood Oxygenation: An In Vivo Study in Sheep

Background: Current, invasive cerebral oxygenation monitors require either retrograde jugular venous bulb cannulation or intraparenchymal probe insertion. There is no accurate, noninvasive, continuous monitor of cerebral blood oxygenation. Methods: The authors designed, built, and tested novel optoacoustic instrumentation that continuously measures blood oxygenation in the superior sagittal sinus (SSS) in vivo in 12 anesthetized sheep. In this technique, laser pulses generate acoustic signals, the amplitudes and slopes of which are proportional to oxyhemoglobin saturation in the SSS. Optoacoustic signals from the SSS measured through the scalp and cranium were compared with directly measured oxyhemoglobin saturation in blood withdrawn from the cannulated SSS. Results: In the first experiments (feasibility), Fio2 changes produced rapid corresponding changes in optoacoustic signals and arterial oxygen saturation. In the second experiments (validation), the authors correlated oxyhemoglobin saturation in the SSS with optoacoustic signals and developed quantifying algorithms. In eight of nine validation experiments, the authors quantified optoacoustic signals by subtracting the temporal profile at low Fio2 (0.08–0.1) from profiles at higher Fio2 and integrating those signals in the range from 3 to 5 &mgr;s. In each validation experiment, optoacoustic signals showed tight temporal association and good linear correlation with measured oxyhemoglobin saturation (r2 0.75 to 0.99 for eight individual experiments). Conclusions: The optoacoustic system detects signals induced in the SSS and optoacoustic signals from the SSS linearly correlate with oxyhemoglobin saturation. The data suggest that the optoacoustic technique merits clinical evaluation.

[1]  D. Delpy,et al.  Characterization of the near infrared absorption spectra of cytochrome aa3 and haemoglobin for the non-invasive monitoring of cerebral oxygenation. , 1988, Biochimica et biophysica acta.

[2]  K. Kiening,et al.  Multimodal monitoring in patients with head injury: evaluation of the effects of treatment on cerebral oxygenation. , 1997, The Journal of trauma.

[3]  W. White,et al.  Jugular bulb saturation and cognitive dysfunction after cardiopulmonary bypass. , 1994, The Annals of thoracic surgery.

[4]  M. C. Rogers,et al.  Noninvasive determination of hemoglobin saturation in dogs by derivative near-infrared spectroscopy. , 1989, The American journal of physiology.

[5]  Frank K. Tittel,et al.  Laser optoacoustic tomography for medical diagnostics: experiments with biological tissues , 1996, Photonics West.

[6]  R. Bullock,et al.  Continuous monitoring of cerebral substrate delivery and clearance: initial experience in 24 patients with severe acute brain injuries. , 1997, Neurosurgery.

[7]  H. Winn,et al.  A critique of the intraoperative use of jugular venous bulb catheters during neurosurgical procedures. , 1994, Anesthesia and analgesia.

[8]  I. Chaudry,et al.  Testosterone: the crucial hormone responsible for depressing myocardial function in males after trauma-hemorrhage. , 1998, Annals of surgery.

[9]  V S Letokhov,et al.  Studies of acoustical and shock waves in the pulsed laser ablation of biotissue , 1993, Lasers in surgery and medicine.

[10]  C. Robertson,et al.  Monitoring of cerebral hemodynamics with jugular bulb catheters. , 1997, Critical care clinics.

[11]  W. Alves,et al.  Continuous monitoring of cerebral oxygenation in acute brain injury: injection of mannitol during hyperventilation. , 1990, Journal of neurosurgery.

[12]  B. Wilson,et al.  Time resolved reflectance and transmittance for the non-invasive measurement of tissue optical properties. , 1989, Applied optics.

[13]  J D Pickard,et al.  An observational study of near-infrared spectroscopy during carotid endarterectomy. , 1995, Journal of neurosurgery.

[14]  K. Kiening,et al.  Multimodal Monitoring in Patients with Head Injury , 1997 .

[15]  R G Grossman,et al.  Jugular venous desaturation and outcome after head injury. , 1994, Journal of neurology, neurosurgery, and psychiatry.

[16]  R. Esenaliev,et al.  Sensitivity of laser opto-acoustic imaging in detection of small deeply embedded tumors , 1999 .

[17]  Kirill V. Larin,et al.  Comparison of optoacoustic tomography with ultrasound and x-ray imaging for breast cancer detection , 2001, SPIE BiOS.

[18]  Britton Chance,et al.  Near-infrared Measurement of Cerebral Oxygenation: Correlation with Electroencephalographic Ischemia during Ventricular Fibrillation , 1995, Anesthesiology.

[19]  Benjamin A. Rockwell,et al.  Procedure for the computation of hazards from diffusely scattering surfaces under the Z136.1-2000 American National Standard for Safe Use of Lasers , 2007 .

[20]  M Uzura,et al.  Prevention of secondary ischemic insults after severe head injury. , 1999, Critical care medicine.

[21]  Massoud Motamedi,et al.  Optoacoustic technique for noninvasive monitoring of blood oxygenation: a feasibility study. , 2002, Applied optics.

[22]  A. Lam,et al.  Isoflurane-induced hypotension and vital organ blood flow. , 1994, Anesthesia and Analgesia.