Anal. Chem. 2015, 87, 907−913. DOI: 10.1021/ac5028758 H we carefully consider and reply to the comments raised by Dr. Dunbar regarding the accuracy of our presented data process for nanopore analysis. Our work focuses on current blockage location by improving the accuracy of local threshold approach and the evaluation of current amplitude by applying an integration method. In this response, we provide a more detailed description of second-order-differential-based calibration (DBC) method. Moreover, the advantages of our proposed method have been discussed by comparing with conventional methods. Thanks to the simulation method provided in the comment, we further built a calibration method to decrease the errors in evaluation of short blockages in nanopore studies. Our improved methods are useful for the problem of extracting information from blockages which are faster than the instrument response. The pulse train model is a simplified model for processing the blockage current acquired in experiments. We agree with the opinions from Dr. Dunbar that the current model should be carefully used in a part of nanopore signal analysis, where the original shape of current blockage may appear to be ramplike. Therefore, we considered the pulse train model and data process based on this model is not appropriate for all of the nanopore experimental results. It can be used in the experiments where the transition between open pore state and blockage state is faster than the instrument response (up to 100 kHz bandwidth at current stage). In our method, the DBC method is developed to precisely locate the region of blockage, which largely eliminates the effect of random noise. Then, we adopt the criterion from Rant’s study to evaluate dwell time. It should be noted that the DBC method is not limited to the applications which are based on Rant’s criterion. DBC method could be incorporated into many other criterions of dwell time. As kindly proved in the comment, the unfiltered blockage and its filtered version have equal areas. In other words, the integrations of filtered blockage currents are hardly affected by the low-pass filter. Therefore, we adopted integrated area in calculating the current amplitude from the attenuated events. We appreciated that Dr. Dunbar provided good references and software for nanopore data analysis. The present methods for nanopore data analysis were listed but not limited in Table 1. The OpenNanopore software extracts multilevel information in the blockages from the solid-state nanopore by using the cumulative sums algorithm. The attenuations on the blockages induced by the low-pass filter are not a major concern in this software. For locating the blockage in the data process, the OpenNanopore uses localized thresholds method. In contrast, the DBC method eliminates the errors originating from the setting of thresholds for the blockages with unavoidable noise at two edges and the integrations of blockage amplitude we proposed are independent of the bandwidth. The QUB, another software suggested in the comment, is a professional software for single channel data analysis. It aims to simulate kinetics of single molecule and owns the advanced features in statistical analysis based on Hidden Markov model and K-mean algorithm. The studies mentioned in the comment (refs 10−12 in the comment) about the Hidden Markov model were not used in analyzing real data for blockage detection or did not take the influence of the filter into consideration. However, our methods exhibit good performances in analyzing real data from α-hemolysin nanopore experiments. Thus, our method has the advantage among the present process for nanopore data analysis. Prior to the implementation of the DBC method, we applied a Fourier series to fit the experimental blockages, which showed a good performance. Note that the role of fitting process is only to smooth the signal data. The fitted function is not based on the circuit model of the system. Therefore, the fitted parameters are not relevant to the frequency response of the system. Here, we listed the fitted parameters of the 4th-order Fourier series which are asked for in the comment (Table 2). As a kind reminder, we noticed that the description of the conventional method for evaluating the dwell time might lead to a misunderstanding. In our paper, the conventional method uses Ps2 to Pe4 in the measurement of dwell time, while the DBC method uses Ps3 to Pe4 in the measurement of dwell time. Briefly, both the conventional and DBC method chose the same stop point as Pe4 but use the different start points. Particularly, the comment raised a concern about the “criterion” of the conventional method used in the comparison of dwell time. The dwell time definition of Ps2 and Pe4 is a conventional method originating from Rant’s study. The points of Ps2 and Pe2 are located by using a threshold and the tracking back routine, which is similar to the two-threshold method. Both of these two methods are widely used in automatic data processes for searching the start and stop point of the blockage in nanopore analysis. However, the filter would affect the dwell time of blockages. Rant’s group proposed a modified criterion to measure the dwell time of blockage by choosing “the last (or only) local minimum of the pulse before the signal starts to return” as the stop point to cut down the overestimation of dwell time. Here we adopted their definitions as a conventional one. Therefore, the stop point is regarded as Pe4 for defining the conventional dwell time. The start point in their criterion is located as the last data point before the current drops below the baseline, Comment
[1]
U. Rant,et al.
Data analysis of translocation events in nanopore experiments.
,
2009,
Analytical chemistry.
[2]
F Sachs,et al.
Hidden Markov modeling for single channel kinetics with filtering and correlated noise.
,
2000,
Biophysical journal.
[3]
J. Behrends,et al.
High-Resolution Size-Discrimination of Single Nonionic Synthetic Polymers with a Highly Charged Biological Nanopore.
,
2015,
ACS nano.
[4]
H. Bayley,et al.
Nucleobase Recognition by Truncated α-Hemolysin Pores.
,
2015,
ACS nano.
[5]
Mark Akeson,et al.
Error rates for nanopore discrimination among cytosine, methylcytosine, and hydroxymethylcytosine along individual DNA strands
,
2013,
Proceedings of the National Academy of Sciences.
[6]
C Raillon,et al.
Fast and automatic processing of multi-level events in nanopore translocation experiments.
,
2012,
Nanoscale.
[7]
Cees Dekker,et al.
Fast translocation of proteins through solid state nanopores.
,
2013,
Nano letters.
[8]
U. Rant,et al.
Electrically facilitated translocations of proteins through silicon nitride nanopores: conjoint and competitive action of diffusion, electrophoresis, and electroosmosis.
,
2010,
Nano letters.
[9]
Yi-Lun Ying,et al.
Accurate data process for nanopore analysis.
,
2015,
Analytical chemistry.
[10]
Jürgen Rühe,et al.
Nanopore-based single-molecule mass spectrometry on a lipid membrane microarray.
,
2011,
ACS nano.
[11]
F. Qin,et al.
Estimating single-channel kinetic parameters from idealized patch-clamp data containing missed events.
,
1996,
Biophysical journal.
[12]
C. Dekker,et al.
Data analysis methods for solid-state nanopores
,
2015,
Nanotechnology.
[13]
F J Sigworth,et al.
Applying hidden Markov models to the analysis of single ion channel activity.
,
2002,
Biophysical journal.
[14]
J. Betton,et al.
Sensing proteins through nanopores: fundamental to applications.
,
2012,
ACS chemical biology.
[15]
Arvind Balijepalli,et al.
Quantifying Short-Lived Events in Multistate Ionic Current Measurements
,
2014,
ACS nano.
[16]
Gang Wang,et al.
Modeling the Biological Nanopore Instrument for Biomolecular State Estimation
,
2013,
IEEE Transactions on Control Systems Technology.