First American experience with the Terumo DuraHeart™ left ventricular assist system

Since the first implantation of a left ventricular assist system (LVAS) 45 years ago, LVAS therapy has emerged as a viable option for the treatment of advanced heart failure. The current generation of LVASs in clinical evaluation has design features enabling longer and more reliable support durations. We describe the operating characteristics of the DuraHeart™ LVAS (Terumo Heart, Inc., Ann Arbor, MI). The DuraHeart™ LVAS is a magnetically-levitated centrifugal pump that began a FDA-approved clinical trial for evaluation of bridge to transplant indication in July of 2008. Magnetic levitation of the spinning-pump impeller is hypothesized to improve long-term mechanical reliability and biological compatibility of the pump. Other design features make the DuraHeart™ LVAS particularly suited for implantation without cardiopulmonary bypass (CPB). A description of the implant procedure for the first six American implants of the DuraHeart™ LVAS both on-CPB and off-CPB, including CPB techniques employed, are discussed. While it is still very early in the DuraHeart™ LVAS experience, the initial outcomes of the first six patient implants would suggest that the device is a safe and effective LVAS.

[1]  C. Selzman,et al.  Off‐Pump Insertion of Continuous Flow Left Ventricular Assist Devices , 2007, Journal of cardiac surgery.

[2]  T. Myers,et al.  Thirty-Five Years of Mechanical Circulatory Support at the Texas Heart Institute , 2005 .

[3]  T Akutsu,et al.  Terumo implantable left ventricular assist system: results of long-term animal study. , 2000, ASAIO journal.

[4]  Victor L Poirier,et al.  Design Features, Developmental Status, and Experimental Results With the Heartmate III Centrifugal Left Ventricular Assist System With a Magnetically Levitated Rotor , 2007, ASAIO journal.

[5]  D. Adams,et al.  Off-pump implant of the Jarvik 2000 ventricular assist device through median sternotomy. , 2007, Annals of Thoracic Surgery.

[6]  Heinrich Schima,et al.  The DuraHeart VAD, a magnetically levitated centrifugal pump: the University of Vienna bridge-to-transplant experience. , 2006, Circulation journal : official journal of the Japanese Circulation Society.

[7]  O. Frazier,et al.  Effect of Pump Flow Mode of Novel Left Ventricular Assist Device Upon End Organ Perfusion in Dogs With Doxorubicin Induced Heart Failure , 2005, ASAIO journal.

[8]  Tadahiko Shinshi,et al.  Third-generation blood pumps with mechanical noncontact magnetic bearings. , 2006, Artificial organs.

[9]  F. Pagani Continuous-flow rotary left ventricular assist devices with "3rd generation" design. , 2008, Seminars in thoracic and cardiovascular surgery.

[10]  C. Hall,et al.  PROLONGED ASSISTED CIRCULATION DURING AND AFTER CARDIAC OR AORTIC SURGERY. PROLONGED PARTIAL LEFT VENTRICULAR BYPASS BY MEANS OF INTRACORPOREAL CIRCULATION. , 1963, The American journal of cardiology.

[11]  Setsuo Takatani,et al.  Mechanical circulatory support devices (MCSD) in Japan: current status and future directions , 2005, Journal of Artificial Organs.

[12]  O H Frazier,et al.  Thirty-five years of mechanical circulatory support at the Texas Heart Institute: an updated overview. , 2005, Texas Heart Institute journal.

[13]  Georg Wieselthaler,et al.  293: Initial results of a European multicenter clinical trial with the DuraHeart® Mag-Lev centrifugal left ventricular assist device , 2006 .

[14]  Katharine H Fraser,et al.  The use of computational fluid dynamics in the development of ventricular assist devices. , 2011, Medical engineering & physics.

[15]  O. Frazier Implantation of the Jarvik 2000 left ventricular assist device without the use of cardiopulmonary bypass. , 2003, The Annals of thoracic surgery.