Evidence of Time-Varying Myocardial Contribution by In Vivo Magnitude and Phase Measurement in Mice

Cardiac volume can be estimated by a conductance catheter system. Both blood and myocardium are conductive, but only the blood conductance is desired. Therefore, the parallel myocardium contribution should be removed from the total measured conductance. Several methods have been developed to estimate the contribution from myocardium, and they only determine a single steady state value for the parallel contribution. Besides, myocardium was treated as purely resistive or mainly capacitive when estimating the myocardial contribution. We question these assumptions and propose that the myocardium is both resistive and capacitive, and its contribution changes during a single cardiac cycle. In vivo magnitude and phase experiments were performed in mice to confirm this hypothesis.

[1]  Richard D. White,et al.  Estimation of current leakage in left and right ventricular conductance volumetry using a dynamic finite element model , 2000, IEEE Transactions on Biomedical Engineering.

[2]  A A Shoukas,et al.  Does volume catheter parallel conductance vary during a cardiac cycle? , 1990, The American journal of physiology.

[3]  D. Kass,et al.  Estimation of parallel conductance by dual-frequency conductance catheter in mice. , 2000, American journal of physiology. Heart and circulatory physiology.

[4]  T. Skalak,et al.  Accuracy of the conductance catheter for measurement of ventricular volumes seen clinically: effects of electric field homogeneity and parallel conductance , 1997, IEEE Transactions on Biomedical Engineering.

[5]  C Gabriel,et al.  The dielectric properties of biological tissues: I. Literature survey. , 1996, Physics in medicine and biology.

[6]  Jan Baan,et al.  Computation of the Input Impedances of a Catheter for Cardiac Volumetry , 1984, IEEE Transactions on Biomedical Engineering.

[7]  Jonathan W. Valvano,et al.  3D finite element complex domain numerical models of electric fields in blood and myocardium , 2003, Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439).

[8]  John G. Webster,et al.  Medical Instrumentation: Application and Design , 1997 .

[9]  W L Maughan,et al.  Use of a conductance (volume) catheter and transient inferior vena caval occlusion for rapid determination of pressure-volume relationships in man. , 1988, Catheterization and cardiovascular diagnosis.

[10]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[11]  B Buis,et al.  Continuous measurement of left ventricular volume in animals and humans by conductance catheter. , 1984, Circulation.

[12]  D. Cheng Field and wave electromagnetics , 1983 .

[13]  G L Freeman,et al.  Validation of a mouse conductance system to determine LV volume: comparison to echocardiography and crystals. , 2000, American journal of physiology. Heart and circulatory physiology.

[14]  T J Gawne,et al.  Estimating left ventricular offset volume using dual-frequency conductance catheters. , 1987, Journal of applied physiology.

[15]  H. P. Schwan,et al.  Electrical properties of blood and its constitutents: Alternating current spectroscopy , 1983, Blut: Zeitschrift für die Gesamte Blutforschung.

[16]  J A Pearce,et al.  Development of a multifrequency conductance catheter-based system to determine LV function in mice. , 2000, American journal of physiology. Heart and circulatory physiology.

[17]  D. Kass,et al.  In vivo murine left ventricular pressure-volume relations by miniaturized conductance micromanometry. , 1998, American journal of physiology. Heart and circulatory physiology.

[18]  A. Redington,et al.  The effect of changing excitation frequency on parallel conductance in different sized hearts. , 1998, Cardiovascular research.