Influence of different positions on hemodynamics derived from noninvasive transcutaneous Doppler ultrasound

A proper alignment of the ultrasound beam to the aortic or pulmonary outflow tracts is essential to acquire accurate signals. This study aimed to investigate the influence of different positions on the acquisition of Doppler signals using a noninvasive transcutaneous Doppler ultrasound. This was a prospective observational crossover study. Two operators performed hemodynamics measurements on each subject in supine, sitting, semirecumbent, passive leg raising (PLR) 20°, and PLR 60° positions using both aortic and pulmonary approaches. All Doppler flow profile images were assessed using the Fremantle and Prince of Wales Hospital criteria. Time required to obtain Doppler signals was recorded. A total of 60 subjects (50% males) aged 18–60 years old were investigated. In both sitting and semirecumbent positions, aortic stroke volume indexes (SVIs) and cardiac indexes (CIs) were significantly lower than those in the other three positions while the pulmonary CIs were comparable to that in the supine position. In the sitting position, the aortic signal qualities were lower and the time to obtain the pulmonary Doppler signals was prolonged. Instead, the signal quality and the time to obtain the Doppler signals in the semirecumbent position were similar to those in the other three positions using the pulmonary approach. PLR did not cause a significant increase in SVI regardless of the degree of leg elevation. These data show that it is feasible to perform the noninvasive transcutaneous Doppler ultrasound using the pulmonary approach in the semirecumbent position for patients unable to maintain the supine position. The aortic approach in the sitting and semirecumbent positions is not suitable as it is not sufficiently reliable.

[1]  T. Rainer,et al.  Noninvasive Doppler ultrasound cardiac output monitor for the differential diagnosis of shock. , 2012, The American journal of emergency medicine.

[2]  J. Monagle,et al.  Does Patient Position Influence Doppler Signal Quality from the USCOM Ultrasonic Cardiac Output Monitor? , 2008, Anesthesia and analgesia.

[3]  A. Mottrie,et al.  Influence of steep Trendelenburg position and CO(2) pneumoperitoneum on cardiovascular, cerebrovascular, and respiratory homeostasis during robotic prostatectomy. , 2010, British journal of anaesthesia.

[4]  T. Rainer,et al.  The normal ranges of cardiovascular parameters in children measured using the Ultrasonic Cardiac Output Monitor , 2010, Critical care medicine.

[5]  H. Nguyen,et al.  Interrater reliability of cardiac output measurements by transcutaneous Doppler ultrasound: implications for noninvasive hemodynamic monitoring in the ED. , 2006, The American journal of emergency medicine.

[6]  A. Jarquin-Valdivia,et al.  Use of the Trendelenburg position as the resuscitation position: to T or not to T? , 2005, American journal of critical care : an official publication, American Association of Critical-Care Nurses.

[7]  J. Mantz,et al.  Feasibility of cardiac output estimation by ultrasonic cardiac output monitoring in the prehospital setting , 2011, European journal of emergency medicine : official journal of the European Society for Emergency Medicine.

[8]  P. V. van Heerden,et al.  Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit. , 2005, British journal of anaesthesia.

[9]  A. Weyland,et al.  Effects of the sitting position on the distribution of blood volume in patients undergoing neurosurgical procedures. , 2000, British journal of anaesthesia.

[10]  B. Molloy Implications for postoperative visual loss: steep trendelenburg position and effects on intraocular pressure. , 2011, AANA journal.

[11]  Huang-Ping Yu,et al.  Reliability of a new ultrasonic cardiac output monitor in recipients of living donor liver transplantation , 2008, Liver transplantation : official publication of the American Association for the Study of Liver Diseases and the International Liver Transplantation Society.

[12]  A. Goetz,et al.  Trendelenburg positioning after cardiac surgery: effects on intrathoracic blood volume index and cardiac performance , 2003, European journal of anaesthesiology.

[13]  M. Irwin,et al.  Comparison of the USCOM ultrasound cardiac output monitor with pulmonary artery catheter thermodilution in patients undergoing liver transplantation , 2008, Liver transplantation : official publication of the American Association for the Study of Liver Diseases and the International Liver Transplantation Society.

[14]  J. Teboul,et al.  Passive leg raising , 2008, Intensive Care Medicine.

[15]  P. Sprivulis,et al.  Emergency physicians can reliably assess emergency department patient cardiac output using the USCOM continuous wave Doppler cardiac output monitor , 2005, Emergency medicine Australasia : EMA.

[16]  G. Borm,et al.  Clinical validation of the non‐invasive cardiac output monitor USCOM‐1A in critically ill patients , 2008, European journal of anaesthesiology.

[17]  O. Thom,et al.  Comparison of a supra-sternal cardiac output monitor (USCOM) with the pulmonary artery catheter. , 2009, British journal of anaesthesia.

[18]  J. Achard,et al.  Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients. , 2002, Chest.

[19]  J. Herlitz,et al.  Passive leg raising during cardiopulmonary resuscitation in out-of-hospital cardiac arrest--does it improve circulation and outcome? , 2010, Resuscitation.

[20]  P. Palange,et al.  From the authors , 2007, European Respiratory Journal.

[21]  Jack Copeland,et al.  Noninvasive Cardiac Output Measurement in Heart Failure Subjects on Circulatory Support , 2009, Anesthesia and analgesia.