Quantitative wavelet domain image processing of dynamic PET data

Neuroreceptor PET studies consisting of long dynamic data acquisitions result in data with low signal-to-noise ratio and limited spatial resolution. To address these problems we have developed a 3D wavelet-based image processing tool (wavelet filter, WF), containing both denoising and enhancement functionality. The filter is based on multi-scale thresholding and cross-scale regularization. These operations are data-driven, which may lead to non-linearity effects and hamper quantification of dynamic PET data. The aim of the present study was to investigate these effects using both phantom and human PET data. A phantom study was performed with a cylindrical phantom, filled with 18F, containing a number of spherical inserts filled with 11C. Human studies were performed on 9 healthy volunteers after injection of the serotonine transporter tracer [11C]DASB. Images from both phantom and human studies were reconstructed with filtered backprojection and post-processed by WF with a series of different denoising and enhancement parameter values. The phantom study was analyzed by computing the insert-to-background ratio as a function of time. The human study was analyzed with a 1-tissue compartment model for a series of brain regions. For the phantom study, linear relations were found between unprocessed and WF processed data for positive contrasts. However, for negative contrast, non-linearity effects were observed. For the human data, good correlation was obtained between results from unprocessed and WF processed data. Our results showed that, although non-linear effects may appear in low-contrast areas, it is possible to achieve accurate quantification with wavelet-based image processing

[1]  Yinpeng Jin,et al.  Regularization of PET reconstruction using multi-scale adaptive thresholding , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[2]  F E Turkheimer,et al.  Modeling Dynamic PET-SPECT Studies in the Wavelet Domain , 2000, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[3]  R. Parsey,et al.  In vivo Quantification of Serotonin Transporters Using [11C]DASB and Positron Emission Tomography in Humans: Modeling Considerations , 2007, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[4]  José Guimón,et al.  Wavelet Analysis of Dynamic PET Data: Application to the Parametric Imaging of Benzodiazepine Receptor Concentration , 2000, NeuroImage.

[5]  Cyril Riddell,et al.  A linear wavelet filter for parametric imaging with dynamic PET , 2003, IEEE Transactions on Medical Imaging.

[6]  Elsa D. Angelini,et al.  De-noising SPECT/PET Images Using Cross-Scale Regularization , 2003, MICCAI.

[7]  Lars Farde,et al.  Wavelet-Aided Parametric Mapping of Cerebral Dopamine D2 Receptors Using the High Affinity PET Radioligand [11C]FLB 457 , 2002, NeuroImage.

[8]  Mark Lubberink,et al.  Improving accuracy and precision of PET pharmacokinetic analysis using wavelet based denoising of time activity curves , 2005 .

[9]  R. Ogden,et al.  In vivo quantification of serotonin transporters using [C-11]DASB and positron emission tomography in humans: modeling considerations (vol 27, pg 205, 2007) , 2007 .

[10]  F E Turkheimer,et al.  Multiresolution Analysis of Emission Tomography Images in the Wavelet Domain , 1999, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[11]  Ramin V. Parsey,et al.  Acute Occupancy of Brain Serotonin Transporter by Sertraline as Measured by [11C]DASB and Positron Emission Tomography , 2006, Biological Psychiatry.

[12]  Anthonin Reilhac,et al.  Optimization of dynamic measurement of receptor kinetics by wavelet denoising , 2006, NeuroImage.

[13]  Andrew F. Laine,et al.  Regularization in tomographic reconstruction using thresholding estimators , 2003, IEEE Transactions on Medical Imaging.