Effects of scattered x-rays on monoenergetic cone-beam 3D CT images

Scatter to primary radiation ratios at detector positions were calculated for spherical water phantoms in the cone-beam x-ray 3D CT scanner using the Monte Carlo simulation method. In the Monte Carlo simulation, 1 approximately 4 X 106 photons of cone-beamed several monoenergetic x-rays have been traced individually as these photons interact within the phantoms with diameters 10 and 15 cm. In case of the incident photon energies are 72.86 and 68.79 keV, photon spectra at the center of the planar detector system are depicted. The decrease in CT number due to scatter was found to be about 100. The scatter reduces CT numbers in the whole region of images and the intensity of scattered rays is nearly uniform, so that rounded-off image is reconstructed.

[1]  Mehrdad Soumekh,et al.  Image reconstruction techniques in tomographic imaging systems , 1986, IEEE Trans. Acoust. Speech Signal Process..

[2]  Scott Kirkwood Gordon ANALOG RECONSTRUCTION METHODS FOR TRANSAXIAL TOMOGRAPHY , 1977 .

[3]  Victor J. Sank,et al.  DEFINITIONS OF EFFECTIVE ENERGY IN COMPUTED TOMOGRAPHY , 1981, Physics in medicine and biology.

[4]  W. Kalender,et al.  An algorithm for noise suppression in dual energy CT material density images. , 1988, IEEE transactions on medical imaging.

[5]  C E Floyd,et al.  Energy and spatial distribution of multiple order Compton scatter in SPECT: a Monte Carlo investigation. , 1984, Physics in medicine and biology.

[6]  L. Burkinshaw,et al.  Tomographic Reconstruction from Experimentally Obtained Cone-Beam Projections , 1987, IEEE Transactions on Medical Imaging.

[7]  Thomas H. Newton,et al.  Technical aspects of computed tomography , 1981 .

[8]  G. N. Ramachandran,et al.  Three-dimensional reconstruction from radiographs and electron micrographs: application of convolutions instead of Fourier transforms. , 1971, Proceedings of the National Academy of Sciences of the United States of America.

[9]  S K Hilal,et al.  True three-dimensional cone-beam reconstruction (TTCR) algorithm. , 1989, IEEE transactions on medical imaging.

[10]  Gabor T. Herman,et al.  Image Reconstruction From Projections , 1975, Real Time Imaging.

[11]  P Spanne X-ray energy optimisation in computed microtomography. , 1989, Physics in medicine and biology.

[12]  Gabor T. Herman,et al.  Image reconstruction from projections : the fundamentals of computerized tomography , 1980 .

[13]  G. Minerbo Convolutional Reconstruction from Cone-Beam Projection Data , 1979, IEEE Transactions on Nuclear Science.

[14]  K Doi,et al.  The validity of Monte Carlo simulation in studies of scattered radiation in diagnostic radiology. , 1983, Physics in medicine and biology.

[15]  Bruce D. Smith Image Reconstruction from Cone-Beam Projections: Necessary and Sufficient Conditions and Reconstruction Methods , 1985, IEEE Transactions on Medical Imaging.

[16]  W Kalender,et al.  Monte Carlo calculations of x-ray scatter data for diagnostic radiology. , 1981, Physics in medicine and biology.

[17]  C E Floyd,et al.  Experimentally measured scatter fractions and energy spectra as a test of Monte Carlo simulations. , 1987, Physics in medicine and biology.

[18]  H Kanamori,et al.  Effects of scattered X-rays on CT images. , 1985, Physics in medicine and biology.

[19]  H. Tuy AN INVERSION FORMULA FOR CONE-BEAM RECONSTRUCTION* , 1983 .