Development of an Artificial Finger-Like Knee Loading Device to Promote Bone Health.

This study presents the development of an innovative artificial finger-like device that provides position specific mechanical loads at the end of the long bone and induces mechanotransduction in bone. Bone cells such as osteoblasts are the mechanosensitive cells that regulate bone remodelling. When they receive gentle, periodic mechanical loads, new bone formation is promoted. The proposed device is an under-actuated multi-fingered artificial hand with 4 fingers, each having two phalanges. These fingers are connected by mechanical linkages and operated by a worm gearing mechanism. With the help of 3D printing technology, a prototype device was built mostly using plastic materials. The experimental validation results show that the device is capable of generating necessary forces at the desired frequencies, which are suitable for the stimulation of bone cells and the promotion of bone formation. It is recommended that the device be tested in a clinical study for confirming its safety and efficacy with patients.

[1]  Ping Zhang,et al.  Joint loading-driven bone formation and signaling pathways predicted from genome-wide expression profiles. , 2009, Bone.

[2]  Engin Ozcivici,et al.  Low-Level Vibrations Retain Bone Marrow's Osteogenic Potential and Augment Recovery of Trabecular Bone during Reambulation , 2010, PloS one.

[3]  Ping Zhang,et al.  Knee loading dynamically alters intramedullary pressure in mouse femora. , 2007, Bone.

[4]  A. Goodship,et al.  Bone deformation recorded in vivo from strain gauges attached to the human tibial shaft. , 1975, Acta orthopaedica Scandinavica.

[5]  Teruko Takano-Yamamoto,et al.  Osteocyte function under compressive mechanical force , 2014 .

[6]  R. Kwon,et al.  Microfluidic Enhancement of Intramedullary Pressure Increases Interstitial Fluid Flow and Inhibits Bone Loss in Hindlimb Suspended Mice , 2010, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[7]  T. Albrektsson,et al.  Osteoinduction, osteoconduction and osseointegration , 2001, European Spine Journal.

[8]  Markus A. Wimmer,et al.  The Influence of Mechanical Stimuli on Articular Cartilage Tissue Engineering , 2006 .

[9]  Sohel Anwar,et al.  Development of an Under-Actuated Robotic Device for Knee Loading Applications , 2015 .

[10]  H. Yokota,et al.  Knee loading stimulates healing of mouse bone wounds in a femur neck. , 2011, Bone.

[11]  G M Malacinski,et al.  Joint loading modality: its application to bone formation and fracture healing , 2007, British Journal of Sports Medicine.

[12]  Sohel Anwar,et al.  Development of a Portable Knee Rehabilitation Device That Uses Mechanical Loading. , 2013, Journal of medical devices.