The three-dimensional bone interface of an osseointegrated implant: a method for study.

To clarify the three-dimensional bone structure around a plasma-sprayed hydroxyapatite-coated endosseous dental implant, bone contact with the implant at 75 microns intervals was evaluated. Based on digitized data, three-dimensional graphics of the bone around the implant was clearly shown. These graphics provide adequate information on the bone-implant interface and also suggest development of a realistic finite element model.

[1]  H. Tsuru,et al.  Bone-implant interface structures after nontapping and tapping insertion of screw-type titanium alloy endosseous implants. , 1988, The Journal of prosthetic dentistry.

[2]  G L Kinzel,et al.  Finite element analysis of bone-adapted and bone-bonded endosseous implants. , 1989, The Journal of prosthetic dentistry.

[3]  S D Cook,et al.  A three-dimensional finite element analysis of a porous rooted Co-Cr-Mo alloy dental implant. , 1982, Journal of dental research.

[4]  D. Koth,et al.  The single-crystal sapphire endosteal dental implant: material characteristics and 18-month experimental animal trials. , 1982, The Journal of prosthetic dentistry.

[5]  K. de Groot,et al.  Immediate dental root implants from synthetic dense calcium hydroxylapatite. , 1979, The Journal of prosthetic dentistry.

[6]  H. Tsuru,et al.  Initial interface between submerged hydroxyapatite-coated titanium alloy implant and mandibular bone after nontapping and tapping insertions in monkeys. , 1990, The Journal of prosthetic dentistry.

[7]  S D Cook,et al.  Interface mechanics and histology of titanium and hydroxylapatite-coated titanium for dental implant applications. , 1987, The International journal of oral & maxillofacial implants.

[8]  M R Rieger,et al.  Finite element analysis of six endosseous implants. , 1990, The Journal of prosthetic dentistry.

[9]  P I Brånemark,et al.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. , 1981, International journal of oral surgery.

[10]  F Sutter,et al.  The reactions of bone, connective tissue, and epithelium to endosteal implants with titanium-sprayed surfaces. , 1981, Journal of maxillofacial surgery.

[11]  L. Borchers,et al.  Three-dimensional Stress Distribution Around a Dental Implant at Different Stages of Interface Development , 1983, Journal of dental research.

[12]  H. Tsuru,et al.  Initial bone-implant interfaces of submergible and supramergible endosseous single-crystal sapphire implants. , 1986, The Journal of prosthetic dentistry.

[13]  J. Kent,et al.  Evaluation of hydroxylapatite-coated titanium dental implants in dogs. , 1987, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[14]  R. Pilliar,et al.  A Histological Assessment of the Initial Healing Response Adjacent to Porous-surfaced, Titanium Alloy Dental Implants in Dogs , 1986, Journal of dental research.

[15]  P. Watson,et al.  A Histological Evaluation of a Functional Endosseous, Porous-surfaced, Titanium Alloy Dental Implant System in the Dog , 1988, Journal of dental research.

[16]  T. Albrektsson Direct bone anchorage of dental implants. , 1983, The Journal of prosthetic dentistry.

[17]  D Buser,et al.  Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. , 1991, Journal of biomedical materials research.

[18]  L. Hench,et al.  Analysis of bioglass fixation of hip prostheses. , 1977, Journal of Biomedical Materials Research.